These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
104 related items for PubMed ID: 26964236
1. [Gas Concentration Measurement Based on the Integral Value of Absorptance Spectrum]. Liu HJ, Tao SH, Yang BC, Deng HG. Guang Pu Xue Yu Guang Pu Fen Xi; 2015 Dec; 35(12):3490-4. PubMed ID: 26964236 [Abstract] [Full Text] [Related]
2. [A Detection Technique for Gas Concentration Based on the Spectral Line Shape Function]. Zhou M, Yang BC, Tao SH. Guang Pu Xue Yu Guang Pu Fen Xi; 2015 Apr; 35(4):881-4. PubMed ID: 26197567 [Abstract] [Full Text] [Related]
3. [Accurate calculation of spectral line profiles by considering influence of varying pressure and temperature in a gas]. Chen Z, Tao SH, Du XJ, Hou XJ. Guang Pu Xue Yu Guang Pu Fen Xi; 2013 Feb; 33(2):312-5. PubMed ID: 23697101 [Abstract] [Full Text] [Related]
4. Study on the Method of Voigt Profiles Two Wings Fitting Non-Uniform Flow Field Absorbance. Nei W, Ye QH, Xu ZY, Zhang GL, Xia HH, Kan RF. Guang Pu Xue Yu Guang Pu Fen Xi; 2017 Mar; 37(3):816-21. PubMed ID: 30160388 [Abstract] [Full Text] [Related]
5. [Simulation of TDLAS direct absorption based on HITRAN database]. Qi RB, He SK, Li XT, Wang XZ. Guang Pu Xue Yu Guang Pu Fen Xi; 2015 Jan; 35(1):172-7. PubMed ID: 25993843 [Abstract] [Full Text] [Related]
6. Variation of Absorptance-Curve Shape With Changes in Pigment Concentration. Howett GL. J Res Natl Bur Stand A Phys Chem; 1968 Jan; 72A(4):309-340. PubMed ID: 31824099 [Abstract] [Full Text] [Related]
7. [A line-by-line trace gas absorption model and its application in NDIR gas detection technology]. Fang J, Liu WQ, Zhang TS. Guang Pu Xue Yu Guang Pu Fen Xi; 2008 Jun; 28(6):1269-72. PubMed ID: 18800702 [Abstract] [Full Text] [Related]
9. [Research on On-Line Calibration Based Photoacoustic Spectrometry System for Monitoring the Concentration of CO2 in Atmosphere]. Zhang JF, Pan SQ, Lin XL, Hu PB, Chen ZM. Guang Pu Xue Yu Guang Pu Fen Xi; 2016 Jan; 36(1):1-5. PubMed ID: 27228729 [Abstract] [Full Text] [Related]
11. [Study on online self-calibration technique for trace gas analyzer based on tunable diode laser absorption spectroscopy]. Zhang J, Zhu Y, Chen JQ, Liang B. Guang Pu Xue Yu Guang Pu Fen Xi; 2010 Apr; 30(4):1030-4. PubMed ID: 20545155 [Abstract] [Full Text] [Related]
12. [Remote system of natural gas leakage based on multi-wavelength characteristics spectrum analysis]. Li J, Lu XT, Yang ZH. Guang Pu Xue Yu Guang Pu Fen Xi; 2014 May; 34(5):1249-52. PubMed ID: 25095416 [Abstract] [Full Text] [Related]
13. Stellar and 0ther high-temperature molecules. Weltner W. Science; 1967 Jan 13; 155(3759):155-64. PubMed ID: 17738213 [Abstract] [Full Text] [Related]
14. The absorption of laser radiation along atmospheric slant paths. Plass GN. Appl Opt; 1966 Jan 01; 5(1):149-54. PubMed ID: 20048801 [Abstract] [Full Text] [Related]
15. Absorptance of nonferrous alloys to Nd:YLF and Nd:YAG laser light at room temperature. Bergström D, Powell J, Kaplan AF. Appl Opt; 2007 Mar 10; 46(8):1290-301. PubMed ID: 17318249 [Abstract] [Full Text] [Related]
16. [Synchronous measurement of concentrations of nitric oxide and nitric dioxide in flue gas by ultraviolet absorption analysis]. Zhou J, Zhang SL. Guang Pu Xue Yu Guang Pu Fen Xi; 2008 Apr 10; 28(4):870-4. PubMed ID: 18619318 [Abstract] [Full Text] [Related]
17. Calibration optimization of laser-induced deflection signal for measuring absorptance of laser components. Zhang X, Li B. Appl Opt; 2015 Mar 10; 54(8):1861-9. PubMed ID: 25968359 [Abstract] [Full Text] [Related]
19. Measurement of light absorption by aquatic particles: improvement of the quantitative filter technique by use of an integrating sphere approach. Röttgers R, Gehnke S. Appl Opt; 2012 Mar 20; 51(9):1336-51. PubMed ID: 22441480 [Abstract] [Full Text] [Related]