These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
168 related items for PubMed ID: 27028737
21. Guidance for storing blood samples in laboratories performing complete blood count with differential. Cornet E, Behier C, Troussard X. Int J Lab Hematol; 2012 Dec; 34(6):655-60. PubMed ID: 22823600 [Abstract] [Full Text] [Related]
22. Effectiveness of citrate buffer-fluoride mixture in Terumo tubes as an inhibitor of in vitro glycolysis. Bonetti G, Carta M, Montagnana M, Lo Cascio C, Bonfigli AR, Mosca A, Testa R, Italian joint SIBioC-SIPMeL Study Group on Diabetes Mellitus. Biochem Med (Zagreb); 2016 Dec; 26(1):68-76. PubMed ID: 26981020 [Abstract] [Full Text] [Related]
23. Blood collection technique, anticoagulants and storing temperature have minor effects on the isolation of polymorphonuclear neutrophils. Krabbe J, Beilmann V, Alamzad-Krabbe H, Böll S, Seifert A, Ruske N, Kraus T, Martin C. Sci Rep; 2020 Sep 04; 10(1):14646. PubMed ID: 32887919 [Abstract] [Full Text] [Related]
24. Blood from heparin tubes is an acceptable alternative to assess hematocrit determination. Pekar JD, Carpentier T, Maboudou P, Grzych G. Clin Chem Lab Med; 2019 Sep 25; 57(10):e269-e270. PubMed ID: 30903756 [No Abstract] [Full Text] [Related]
25. The use of hirudin as universal anticoagulant in haematology, clinical chemistry and blood grouping. Menssen HD, Melber K, Brandt N, Thiel E. Clin Chem Lab Med; 2001 Dec 25; 39(12):1267-77. PubMed ID: 11798089 [Abstract] [Full Text] [Related]
26. Processing of diagnostic blood specimens: is it really necessary to mix primary blood tubes after collection with evacuated tube system? Lima-Oliveira G, Lippi G, Salvagno GL, Brocco G, Gaino S, Dima F, Volaski W, Rego FG, Picheth G, Guidi GC. Biopreserv Biobank; 2014 Feb 25; 12(1):53-9. PubMed ID: 24620770 [Abstract] [Full Text] [Related]
27. Quality specification in haematology: the automated blood cell count. Buttarello M. Clin Chim Acta; 2004 Aug 02; 346(1):45-54. PubMed ID: 15234635 [Abstract] [Full Text] [Related]
32. Stability of complete blood count parameters with storage: toward defined specifications for different diagnostic applications. Zini G, International Council for Standardization in Haematology (ICSH). Int J Lab Hematol; 2014 Apr 02; 36(2):111-3. PubMed ID: 24373157 [No Abstract] [Full Text] [Related]
34. EDTA, the traditional anticoagulant of haematology: with increased automation is it time for a review? Reardon DM, Warner B, Trowbridge EA. Med Lab Sci; 1991 Jan 02; 48(1):72-5. PubMed ID: 1905774 [No Abstract] [Full Text] [Related]
35. Impact of evacuated collection tube fill volume and mixing on routine coagulation testing using 2.5-ml (pediatric) tubes. Chuang J, Sadler MA, Witt DM. Chest; 2004 Oct 02; 126(4):1262-6. PubMed ID: 15486391 [Abstract] [Full Text] [Related]
36. The international consensus group for hematology review: suggested criteria for action following automated CBC and WBC differential analysis. Barnes PW, McFadden SL, Machin SJ, Simson E, international consensus group for hematology. Lab Hematol; 2005 Oct 02; 11(2):83-90. PubMed ID: 16024331 [Abstract] [Full Text] [Related]