These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


320 related items for PubMed ID: 27043243

  • 1. Numerically simulated exposure of children and adults to pulsed gradient fields in MRI.
    Samoudi AM, Vermeeren G, Tanghe E, Van Holen R, Martens L, Josephs W.
    J Magn Reson Imaging; 2016 Nov; 44(5):1360-1367. PubMed ID: 27043243
    [Abstract] [Full Text] [Related]

  • 2. Exposure of workers to pulsed gradients in MRI.
    Crozier S, Wang H, Trakic A, Liu F.
    J Magn Reson Imaging; 2007 Nov; 26(5):1236-54. PubMed ID: 17969133
    [Abstract] [Full Text] [Related]

  • 3. Assessment of exposure to MRI motion-induced fields based on the International Commission on Non-Ionizing Radiation Protection (ICNIRP) guidelines.
    Zilberti L, Bottauscio O, Chiampi M.
    Magn Reson Med; 2016 Oct; 76(4):1291-300. PubMed ID: 26525160
    [Abstract] [Full Text] [Related]

  • 4. Peripheral nerve stimulation by gradient switching fields in magnetic resonance imaging.
    So PP, Stuchly MA, Nyenhuis JA.
    IEEE Trans Biomed Eng; 2004 Nov; 51(11):1907-14. PubMed ID: 15536892
    [Abstract] [Full Text] [Related]

  • 5. Exposure of Infants to Gradient Fields in a Baby MRI Scanner.
    Tang F, Giaccone L, Hao J, Freschi F, Wu T, Crozier S, Liu F.
    Bioelectromagnetics; 2022 Feb; 43(2):69-80. PubMed ID: 35005795
    [Abstract] [Full Text] [Related]

  • 6. SAR prediction in adults and children by combining measured B1+ maps and simulations at 7.0 Tesla.
    Tiberi G, Costagli M, Biagi L, Ciantis AD, Fontana N, Stara R, Symms MR, Cosottini M, Guerrini R, Tosetti M.
    J Magn Reson Imaging; 2016 Oct; 44(4):1048-55. PubMed ID: 27042956
    [Abstract] [Full Text] [Related]

  • 7. Numerically-simulated induced electric field and current density within a human model located close to a z-gradient coil.
    Li Y, Hand JW, Wills T, Hajnal JV.
    J Magn Reson Imaging; 2007 Nov; 26(5):1286-95. PubMed ID: 17969144
    [Abstract] [Full Text] [Related]

  • 8. Children and adults exposed to low-frequency magnetic fields at the ICNIRP reference levels: theoretical assessment of the induced electric fields.
    Bakker JF, Paulides MM, Neufeld E, Christ A, Chen XL, Kuster N, van Rhoon GC.
    Phys Med Biol; 2012 Apr 07; 57(7):1815-29. PubMed ID: 22411059
    [Abstract] [Full Text] [Related]

  • 9. Electric fields induced in the human body by time-varying magnetic field gradients in MRI: numerical calculations and correlation analysis.
    Bencsik M, Bowtell R, Bowley R.
    Phys Med Biol; 2007 May 07; 52(9):2337-53. PubMed ID: 17440238
    [Abstract] [Full Text] [Related]

  • 10. Measurement of the weighted peak level for occupational exposure to gradient magnetic fields for 1.5 and 3 Tesla MRI body scanners.
    Bonutti F, Tecchio M, Maieron M, Trevisan D, Negro C, Calligaris F.
    Radiat Prot Dosimetry; 2016 Mar 07; 168(3):358-64. PubMed ID: 25987585
    [Abstract] [Full Text] [Related]

  • 11. Peripheral nerve stimulation limits of a high amplitude and slew rate magnetic field gradient coil for neuroimaging.
    Tan ET, Hua Y, Fiveland EW, Vermilyea ME, Piel JE, Park KJ, Ho VB, Foo TKF.
    Magn Reson Med; 2020 Jan 07; 83(1):352-366. PubMed ID: 31385628
    [Abstract] [Full Text] [Related]

  • 12. Numerical dosimetry ELF: accuracy of the method, variability of models and parameters, and the implication for quantifying guidelines.
    Bahr A, Bolz T, Hennes C.
    Health Phys; 2007 Jun 07; 92(6):521-30. PubMed ID: 17495652
    [Abstract] [Full Text] [Related]

  • 13. Electromagnetic fields in the human body due to switched transverse gradient coils in MRI.
    While PT, Forbes LK.
    Phys Med Biol; 2004 Jul 07; 49(13):2779-98. PubMed ID: 15285247
    [Abstract] [Full Text] [Related]

  • 14. Simulation of head-gradient-coil induced electric fields in a human model.
    Feldman RE, Odegaard J, Handler WB, Chronik BA.
    Magn Reson Med; 2012 Dec 07; 68(6):1973-82. PubMed ID: 22294352
    [Abstract] [Full Text] [Related]

  • 15. Investigating cardiac stimulation limits of MRI gradient coils using electromagnetic and electrophysiological simulations in human and canine body models.
    Klein V, Davids M, Schad LR, Wald LL, Guérin B.
    Magn Reson Med; 2021 Feb 07; 85(2):1047-1061. PubMed ID: 32812280
    [Abstract] [Full Text] [Related]

  • 16. Systematic numerical assessment of occupational exposure to electromagnetic fields of transcranial magnetic stimulation.
    D'Agostino S, Colella M, Liberti M, Falsaperla R, Apollonio F.
    Med Phys; 2022 May 07; 49(5):3416-3431. PubMed ID: 35196394
    [Abstract] [Full Text] [Related]

  • 17. Analysis of human brain exposure to low-frequency magnetic fields: a numerical assessment of spatially averaged electric fields and exposure limits.
    Chen XL, Benkler S, Chavannes N, De Santis V, Bakker J, van Rhoon G, Mosig J, Kuster N.
    Bioelectromagnetics; 2013 Jul 07; 34(5):375-84. PubMed ID: 23404214
    [Abstract] [Full Text] [Related]

  • 18. Physiologic and dosimetric considerations for limiting electric fields induced in the body by movement in a static magnetic field.
    Jokela K, Saunders RD.
    Health Phys; 2011 Jun 07; 100(6):641-53. PubMed ID: 22004933
    [Abstract] [Full Text] [Related]

  • 19. The role of skin conductivity in a low frequency exposure assessment for peripheral nerve tissue according to the ICNIRP 2010 guidelines.
    Schmid G, Cecil S, Überbacher R.
    Phys Med Biol; 2013 Jul 07; 58(13):4703-16. PubMed ID: 23774744
    [Abstract] [Full Text] [Related]

  • 20. Analysis and measurements of magnetic field exposures for healthcare workers in selected MR environments.
    Fuentes MA, Trakic A, Wilson SJ, Crozier S.
    IEEE Trans Biomed Eng; 2008 Apr 07; 55(4):1355-64. PubMed ID: 18390326
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 16.