These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
8. Surgical sutureless and transcatheter aortic valves: hemodynamic performance and clinical outcomes in propensity score-matched high-risk populations with severe aortic stenosis. Kamperidis V, van Rosendael PJ, de Weger A, Katsanos S, Regeer M, van der Kley F, Mertens B, Sianos G, Ajmone Marsan N, Bax JJ, Delgado V. JACC Cardiovasc Interv; 2015 Apr 27; 8(5):670-7. PubMed ID: 25946438 [Abstract] [Full Text] [Related]
9. Long-term outcomes of percutaneous paravalvular regurgitation closure after transcatheter aortic valve replacement: a multicenter experience. Saia F, Martinez C, Gafoor S, Singh V, Ciuca C, Hofmann I, Marrozzini C, Tan J, Webb J, Sievert H, Marzocchi A, O'Neill WW. JACC Cardiovasc Interv; 2015 Apr 27; 8(5):681-8. PubMed ID: 25946440 [Abstract] [Full Text] [Related]
10. Heart-rate adjustment of transcatheter haemodynamics improves the prognostic evaluation of paravalvular regurgitation after transcatheter aortic valve implantation. Jilaihawi H, Chakravarty T, Shiota T, Rafique A, Harada K, Shibayama K, Doctor N, Kashif M, Nakamura M, Mirocha J, Rami T, Okuyama K, Cheng W, Sadruddin O, Siegel R, Makkar RR. EuroIntervention; 2015 Aug 27; 11(4):456-64. PubMed ID: 25499834 [Abstract] [Full Text] [Related]
11. 3D Assessment of Features Associated With Transvalvular Aortic Regurgitation After TAVR: A Real-Time 3D TEE Study. Shibayama K, Mihara H, Jilaihawi H, Berdejo J, Harada K, Itabashi Y, Siegel R, Makkar RR, Shiota T. JACC Cardiovasc Imaging; 2016 Feb 27; 9(2):114-23. PubMed ID: 26777225 [Abstract] [Full Text] [Related]
12. Valvular performance and aortic regurgitation following transcatheter aortic valve replacement using Edwards valve versus CoreValve for severe aortic stenosis: A Meta-analysis. Bhatheja S, Panchal HB, Barry N, Mukherjee D, Uretsky BF, Paul T. Cardiovasc Revasc Med; 2016 Jun 27; 17(4):248-55. PubMed ID: 26948087 [Abstract] [Full Text] [Related]
13. Prosthesis-Specific Predictors of Paravalvular Regurgitation after Transcatheter Aortic Valve Replacement: Impact of Calcification and Sizing on Balloon-Expandable versus Self-Expandable Transcatheter Heart Valves. Stähli BE, Nguyen-Kim TD, Gebhard C, Erhart L, Frauenfelder T, Tanner FC, Falk V, Landmesser U, Nietlispach F, Lüscher TF, Maier W, Binder RK. J Heart Valve Dis; 2015 Jan 27; 24(1):10-21. PubMed ID: 26182615 [Abstract] [Full Text] [Related]
14. Clinical outcome and paravalvular leakage of the new balloon-expandable Edwards Sapien 3 valve in comparison to its predecessor model (Edwards Sapien XT) in patients undergoing transfemoral aortic valve replacement. Bocksch W, Grossmann B, Geisler T, Steeg M, Droppa M, Jorbenadze R, Haap M, Gawaz M, Fateh-Moghadam S. Catheter Cardiovasc Interv; 2016 Sep 27; 88(3):466-75. PubMed ID: 27184353 [Abstract] [Full Text] [Related]
15. Automated 3D analysis of pre-procedural MDCT to predict annulus plane angulation and C-arm positioning: benefit on procedural outcome in patients referred for TAVR. Samim M, Stella PR, Agostoni P, Kluin J, Ramjankhan F, Budde RP, Sieswerda G, Algeri E, van Belle C, Elkalioubie A, Juthier F, Belkacemi A, Bertrand ME, Doevendans PA, Van Belle E. JACC Cardiovasc Imaging; 2013 Feb 27; 6(2):238-48. PubMed ID: 23489538 [Abstract] [Full Text] [Related]
16. Transcatheter valve-in-valve implantation for failed balloon-expandable transcatheter aortic valves. Toggweiler S, Wood DA, Rodés-Cabau J, Kapadia S, Willson AB, Ye J, Cheung A, Leipsic J, Binder RK, Gurvitch R, Freeman M, Thompson CR, Svensson LG, Dumont E, Tuzcu EM, Webb JG. JACC Cardiovasc Interv; 2012 May 27; 5(5):571-577. PubMed ID: 22625197 [Abstract] [Full Text] [Related]
17. Hemodynamic classification of paravalvular leakage after transcatheter aortic valve implantation compared with angiographic or echocardiographic classification for prediction of 1-year mortality. Schoechlin S, Brennemann T, Allali A, Ruile P, Jander N, Allgeier M, Gick M, Richardt G, Neumann FJ, Abdel-Wahab M. Catheter Cardiovasc Interv; 2018 May 01; 91(6):E56-E63. PubMed ID: 29105984 [Abstract] [Full Text] [Related]
18. Relative amplitude index: a new tool for hemodynamic evaluation of periprosthetic regurgitation after transcatheter valve implantation. Heinz A, DeCillia M, Feuchtner G, Mueller S, Bartel T, Friedrich G, Grimm M, Mueller LCh, Bonaros N. J Thorac Cardiovasc Surg; 2014 Mar 01; 147(3):1021-8, 1029.e1-2. PubMed ID: 24342900 [Abstract] [Full Text] [Related]
19. Self-Expanding Transcatheter Aortic Valve Replacement Versus Surgical Valve Replacement in Patients at High Risk for Surgery: A Study of Echocardiographic Change and Risk Prediction. Little SH, Oh JK, Gillam L, Sengupta PP, Orsinelli DA, Cavalcante JL, Chang JD, Adams DH, Zorn GL, Pollak AW, Abdelmoneim SS, Reardon MJ, Qiao H, Popma JJ. Circ Cardiovasc Interv; 2016 Jun 01; 9(6):. PubMed ID: 27313280 [Abstract] [Full Text] [Related]
20. Preparatory balloon aortic valvuloplasty during transcatheter aortic valve implantation for improved valve sizing. Patsalis PC, Al-Rashid F, Neumann T, Plicht B, Hildebrandt HA, Wendt D, Thielmann M, Jakob HG, Heusch G, Erbel R, Kahlert P. JACC Cardiovasc Interv; 2013 Sep 01; 6(9):965-71. PubMed ID: 24050862 [Abstract] [Full Text] [Related] Page: [Next] [New Search]