These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
481 related items for PubMed ID: 27127428
1. Retrograde Transcatheter Closure of Mitral Paravalvular Leak through a Mechanical Aortic Valve Prosthesis: 2 Successful Cases. Zhou D, Pan W, Guan L, Qian J, Ge J. Tex Heart Inst J; 2016 Apr; 43(2):137-41. PubMed ID: 27127428 [Abstract] [Full Text] [Related]
2. Transcatheter trans-apical closure of paravalvular mitral and aortic leaks using a new device: first in man experience. Goktekin O, Vatankulu MA, Tasal A, Sönmez O, Başel H, Topuz U, Ergelen M, Hijazi ZM. Catheter Cardiovasc Interv; 2014 Feb; 83(2):308-14. PubMed ID: 23703912 [Abstract] [Full Text] [Related]
3. Multiplug paravalvular leak closure using Amplatzer Vascular Plugs III: A prospective registry. Smolka G, Pysz P, Jasiński M, Roleder T, Peszek-Przybyła E, Ochała A, Wojakowski W. Catheter Cardiovasc Interv; 2016 Feb 15; 87(3):478-87. PubMed ID: 25963541 [Abstract] [Full Text] [Related]
9. Transcatheter closure of mitral paravalvular leak with an arteriovenous wire loop through an aortic mechanical valve prosthesis. Confessore P, Fiorilli F, Scappaticci M, Cifarelli A, De Felice F, Musto C, Violini R. Heart Lung Circ; 2012 Dec 15; 21(12):850-2. PubMed ID: 22784483 [Abstract] [Full Text] [Related]
12. Hopscotch technique: A novel method for percutaneous closure of paravalvular leaks. Ruiz CE, Chi-Hion L, Vladimir J, Gila P, Dillon W, Itzhak K, Chad K. Catheter Cardiovasc Interv; 2017 Apr 15; 89(5):944-950. PubMed ID: 28168809 [Abstract] [Full Text] [Related]
13. Percutaneous complete repair of failed mitral valve prosthesis: simultaneous closure of mitral paravalvular leaks and transcatheter mitral valve implantation - single-centre experience. Kliger C, Angulo R, Maranan L, Kumar R, Jelnin V, Kronzon I, Fontana GP, Plestis K, Patel N, Perk G, Ruiz CE. EuroIntervention; 2015 Mar 15; 10(11):1336-45. PubMed ID: 24800978 [Abstract] [Full Text] [Related]
14. Subacute left ventricular outflow tract obstruction after transapical closure of a mitral paravalvular leak in the region of the aortomitral curtain. Chikkabyrappa S, McElhinney DB, Saric M. Echocardiography; 2016 Nov 15; 33(11):1771-1776. PubMed ID: 27576330 [Abstract] [Full Text] [Related]
15. Successful percutaneous paravalvular leak closure followed by transfemoral aortic lotus valve-in-valve implantation in a degenerated surgical bioprosthesis. Nerla R, Cremonesi A, Castriota F. Catheter Cardiovasc Interv; 2018 Jan 01; 91(1):169-174. PubMed ID: 27143596 [Abstract] [Full Text] [Related]
18. Percutaneous transapical closure of cardiac apex with an ADO-II device after successful transapical transcatheter prosthetic mitral paravalvular leak closure. Iyisoy A, Ozturk C, Celik T, Demirkol S, Cingoz F, Unlu M, Arslan Z. Int J Cardiol; 2015 Jan 01; 189():289-92. PubMed ID: 25917979 [No Abstract] [Full Text] [Related]
19. Paravalvular leak closure with the Amplatzer Vascular Plug III device: immediate and short-term results. Cruz-Gonzalez I, Rama-Merchan JC, Arribas-Jimenez A, Rodriguez-Collado J, Martin-Moreiras J, Cascon-Bueno M, Luengo CM. Rev Esp Cardiol (Engl Ed); 2014 Aug 01; 67(8):608-14. PubMed ID: 25037539 [Abstract] [Full Text] [Related]
20. Characteristics and outcomes of re-do percutaneous paravalvular leak closure. Al-Hijji MA, Alkhouli M, Sarraf M, Zack CJ, Malouf JF, Nkomo VT, Cabalka AK, Reeder GS, Rihal CS, Eleid MF. Catheter Cardiovasc Interv; 2017 Oct 01; 90(4):680-689. PubMed ID: 28185394 [Abstract] [Full Text] [Related] Page: [Next] [New Search]