These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Acoustic radiation force impulse imaging (ARFI) on an IVUS circular array. Patel V, Dahl JJ, Bradway DP, Doherty JR, Lee SY, Smith SW. Ultrason Imaging; 2014 Apr; 36(2):98-111. PubMed ID: 24554291 [Abstract] [Full Text] [Related]
3. Development of an intravascular ultrasound elastography based on a dual-element transducer. Shih CC, Chen PY, Ma T, Zhou Q, Shung KK, Huang CC. R Soc Open Sci; 2018 Apr; 5(4):180138. PubMed ID: 29765694 [Abstract] [Full Text] [Related]
5. Influence of different frequencies and insertion depths on the diagnostic accuracy of liver elastography by acoustic radiation force impulse imaging (ARFI). Potthoff A, Attia D, Pischke S, Kirschner J, Mederacke I, Wedemeyer H, Manns MP, Gebel MJ, Rifai K. Eur J Radiol; 2013 Aug; 82(8):1207-12. PubMed ID: 23523513 [Abstract] [Full Text] [Related]
6. Lower-limb vascular imaging with acoustic radiation force elastography: demonstration of in vivo feasibility. Dumont D, Dahl J, Miller E, Allen J, Fahey B, Trahey G. IEEE Trans Ultrason Ferroelectr Freq Control; 2009 May; 56(5):931-44. PubMed ID: 19473912 [Abstract] [Full Text] [Related]
7. Characterizing stiffness of human prostates using acoustic radiation force. Zhai L, Madden J, Foo WC, Mouraviev V, Polascik TJ, Palmeri ML, Nightingale KR. Ultrason Imaging; 2010 Oct; 32(4):201-13. PubMed ID: 21213566 [Abstract] [Full Text] [Related]
8. Normal values of liver shear wave velocity in healthy children assessed by acoustic radiation force impulse imaging using a convex probe and a linear probe. Fontanilla T, Cañas T, Macia A, Alfageme M, Gutierrez Junquera C, Malalana A, Luz Cilleruelo M, Roman E, Miralles M. Ultrasound Med Biol; 2014 Mar; 40(3):470-7. PubMed ID: 24361222 [Abstract] [Full Text] [Related]
9. Acoustic Radiation Force Impulse (ARFI) imaging-based needle visualization. Rotemberg V, Palmeri M, Rosenzweig S, Grant S, Macleod D, Nightingale K. Ultrason Imaging; 2011 Jan; 33(1):1-16. PubMed ID: 21608445 [Abstract] [Full Text] [Related]
10. The influence of food intake on liver stiffness values assessed by acoustic radiation force impulse elastography-preliminary results. Popescu A, Bota S, Sporea I, Sirli R, Danila M, Racean S, Suseanu D, Gradinaru O, Ivascu Siegfried C. Ultrasound Med Biol; 2013 Apr; 39(4):579-84. PubMed ID: 23415282 [Abstract] [Full Text] [Related]
11. Novel Method for Vessel Cross-Sectional Shear Wave Imaging. He Q, Li GY, Lee FF, Zhang Q, Cao Y, Luo J. Ultrasound Med Biol; 2017 Jul; 43(7):1520-1532. PubMed ID: 28408062 [Abstract] [Full Text] [Related]
17. Acoustic Radiation Force Impulse (ARFI) elastography quantification of muscle stiffness over a course of gradual isometric contractions: a preliminary study. Yavuz A, Bora A, Bulut MD, Batur A, Milanlioglu A, Göya C, Andic C. Med Ultrason; 2015 Mar; 17(1):49-57. PubMed ID: 25745658 [Abstract] [Full Text] [Related]
18. Acoustic radiation force impulse and supersonic shear imaging versus transient elastography for liver fibrosis assessment. Sporea I, Bota S, Jurchis A, Sirli R, Grădinaru-Tascău O, Popescu A, Ratiu I, Szilaski M. Ultrasound Med Biol; 2013 Nov; 39(11):1933-41. PubMed ID: 23932281 [Abstract] [Full Text] [Related]
19. A simulation environment for validating ultrasonic blood flow and vessel wall imaging based on fluid-structure interaction simulations: ultrasonic assessment of arterial distension and wall shear rate. Swillens A, Degroote J, Vierendeels J, Lovstakken L, Segers P. Med Phys; 2010 Aug; 37(8):4318-30. PubMed ID: 20879592 [Abstract] [Full Text] [Related]