These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
355 related items for PubMed ID: 27165606
1. Structural valvular deterioration of Hancock standard valve in the mitral position 33 years after initial implantation. Saisho H, Tayama K, Shimoishi K, Hori H, Okazaki T. J Artif Organs; 2016 Dec; 19(4):408-410. PubMed ID: 27165606 [Abstract] [Full Text] [Related]
2. Malfunction of a Hancock bioprosthesis in the mitral position 24 years after initial implantation. Niinami H, Naito Y, Koyanagi H, Nagashima H, Kasanuki H. J Heart Valve Dis; 2000 Nov; 9(6):810-2. PubMed ID: 11128790 [Abstract] [Full Text] [Related]
3. [A case report: Carpentier-Edwards porcine bioprosthesis malfunction due to the stent dehiscence at 17 years after the implantation in the mitral position]. Hayashi K, Nakano H, Sakamoto T, Okamura H. Kyobu Geka; 2000 Jan; 53(1):79-82. PubMed ID: 10639799 [Abstract] [Full Text] [Related]
4. The case of an explanted 16-year-old mitral Carpentier-Edwards pericardial bioprosthesis. Murayama H, Watanabe T, Yano T, Kida N, Hatano Y, Ohara K, Kobayashi A. J Artif Organs; 2006 Jan; 9(4):259-62. PubMed ID: 17171405 [Abstract] [Full Text] [Related]
5. A case of Carpentier-Edwards pericardial bioprosthesis in mitral position explanted 22 years after implantation. Kubota S, Wakasa S, Ooka T, Tachibana T, Shiiya N, Matsui Y. J Artif Organs; 2010 Apr; 13(1):48-50. PubMed ID: 20162314 [Abstract] [Full Text] [Related]
6. [Re-operation of a mitral porcine bioprosthesis 22-years after implantation]. Soeda M, Hata H, Iida M, Kimura H. Kyobu Geka; 2009 Feb; 62(2):149-51. PubMed ID: 19202937 [Abstract] [Full Text] [Related]
7. Structural valve deterioration of porcine bioprosthesis soon after mitral valve repair and replacement. Takano T, Seto T, Asaka S, Terasaki T, Ohashi N, Fukui D, Amano J. Ann Thorac Cardiovasc Surg; 2014 Feb; 20 Suppl():717-9. PubMed ID: 23666245 [Abstract] [Full Text] [Related]
8. Difference in structural change in the Carpentier-Edwards pericardial valves implanted in the mitral and tricuspid positions. Ohata T, Kigawa I, Wanibuchi Y. Jpn J Thorac Cardiovasc Surg; 2000 Apr; 48(4):242-4. PubMed ID: 10824479 [Abstract] [Full Text] [Related]
9. [Structural changes of Hancock bioprostheses in children (author's transl)]. Bortolotti U, Milano A, Mazzucco A, Callucci V, Valente M, Del Maschio A, Valfrè C, Thiene G. G Ital Cardiol; 1980 Apr; 10(11):1520-5. PubMed ID: 7202899 [Abstract] [Full Text] [Related]
10. Percutaneous Transvenous Transseptal Transcatheter Valve Implantation in Failed Bioprosthetic Mitral Valves, Ring Annuloplasty, and Severe Mitral Annular Calcification. Eleid MF, Cabalka AK, Williams MR, Whisenant BK, Alli OO, Fam N, Pollak PM, Barrow F, Malouf JF, Nishimura RA, Joyce LD, Dearani JA, Rihal CS. JACC Cardiovasc Interv; 2016 Jun 13; 9(11):1161-74. PubMed ID: 27085576 [Abstract] [Full Text] [Related]
11. Morphologic findings in explanted Hancock II porcine bioprostheses. Butany J, Yu W, Silver MD, David TE. J Heart Valve Dis; 1999 Jan 13; 8(1):4-15. PubMed ID: 10096476 [Abstract] [Full Text] [Related]
12. Pannus overgrowth after mitral valve replacement with a Carpentier-Edwards pericardial bioprosthesis. Oda T, Kato S, Tayama E, Fukunaga S, Akashi H, Aoyagi S. J Artif Organs; 2009 Jan 13; 12(1):55-7. PubMed ID: 19330506 [Abstract] [Full Text] [Related]
13. Mitral valve re-replacement for impaired bioprosthesis after 19 years in a patient undergoing steroid treatment. Shimazaki Y, Kuraoka S, Takeda F, Watanabe T, Inui K. J Heart Valve Dis; 2003 Jan 13; 12(1):45-7. PubMed ID: 12578334 [Abstract] [Full Text] [Related]
14. Structural valve deterioration in mitral replacement surgery: comparison of Carpentier-Edwards supra-annular porcine and perimount pericardial bioprostheses. Eric Jamieson WR, Marchand MA, Pelletier CL, Norton R, Pellerin M, Dubiel TW, Aupart MR, Daenen WJ, Holden MP, David TE, Ryba EA, Anderson WN. J Thorac Cardiovasc Surg; 1999 Aug 13; 118(2):297-304. PubMed ID: 10425003 [Abstract] [Full Text] [Related]
15. [Findings of the Carpentier-Edwards porcine bioprosthesis in the mitral position with PTF in the 16th post-operative year]. Matsuzaki K, Koishizawa T, Hiramatsu Y. Kyobu Geka; 1997 Oct 13; 50(11):950-3. PubMed ID: 9330518 [Abstract] [Full Text] [Related]
16. [Acute spontaneous failure of a Carpentier-Edwards porcine mitral valve]. Tota A, Carbone C, Caldarola P. G Ital Cardiol (Rome); 2010 Oct 13; 11(10):789-91. PubMed ID: 21246783 [Abstract] [Full Text] [Related]
17. Structural valve deterioration of a mitral Carpentier-Edwards pericardial bioprosthesis in an 87-year-old woman 16 years after its implantation. Ito H, Sakata K, Haruki T, Kobayashi Y. J Cardiothorac Surg; 2011 Jul 05; 6():88. PubMed ID: 21729285 [Abstract] [Full Text] [Related]
18. Transjugular and transseptal treatment of a degenerated mitral valve prosthesis with a balloon-expandable biological valve. Schaefer U, Frerker C, Busse C, Kuck KH. Heart Lung Circ; 2012 Dec 05; 21(12):836-40. PubMed ID: 22658887 [Abstract] [Full Text] [Related]
19. The Carpentier-Edwards Perimount Magna mitral valve bioprosthesis: intermediate-term efficacy and durability. Loor G, Schuster A, Cruz V, Rafael A, Stewart WJ, Diaz J, McCurry K. J Cardiothorac Surg; 2016 Jan 27; 11():20. PubMed ID: 26818795 [Abstract] [Full Text] [Related]
20. Transfemoral implantation of transcatheter heart valves after deterioration of mitral bioprosthesis or previous ring annuloplasty. Bouleti C, Fassa AA, Himbert D, Brochet E, Ducrocq G, Nejjari M, Ghodbane W, Depoix JP, Nataf P, Vahanian A. JACC Cardiovasc Interv; 2015 Jan 27; 8(1 Pt A):83-91. PubMed ID: 25616821 [Abstract] [Full Text] [Related] Page: [Next] [New Search]