These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
257 related items for PubMed ID: 27189954
1. Multipoint pacing via a quadripolar left-ventricular lead: preliminary results from the Italian registry on multipoint left-ventricular pacing in cardiac resynchronization therapy (IRON-MPP). Forleo GB, Santini L, Giammaria M, Potenza D, Curnis A, Calabrese V, Ricciardi D, D'agostino C, Notarstefano P, Ribatti V, Morani G, Mantica M, Di Biase L, Bertaglia E, Calò L, Zanon F. Europace; 2017 Jul 01; 19(7):1170-1177. PubMed ID: 27189954 [Abstract] [Full Text] [Related]
4. Impact of multipoint pacing on projected battery longevity in cardiac resynchronization therapy. An IRON-MPP study sub-analysis. Forleo GB, Gasperetti A, Ricciardi D, Curnis A, Bertaglia E, Calò L, Pignalberi C, Calzolari V, Ribatti V, Lavalle C, Potenza D, Tondi L, Natale V, Notarstefano P, Viecca M, Morani G, Biffi M, Giammaria M, Zanon F, Santini L. J Cardiovasc Electrophysiol; 2019 Dec 01; 30(12):2885-2891. PubMed ID: 31661172 [Abstract] [Full Text] [Related]
5. Safety and Efficacy of Multipoint Pacing in Cardiac Resynchronization Therapy: The MultiPoint Pacing Trial. Niazi I, Baker J, Corbisiero R, Love C, Martin D, Sheppard R, Worley SJ, Varma N, Lee K, Tomassoni G, MPP Investigators. JACC Clin Electrophysiol; 2017 Dec 26; 3(13):1510-1518. PubMed ID: 29759832 [Abstract] [Full Text] [Related]
6. Cardiac resynchronization therapy by multipoint pacing improves response of left ventricular mechanics and fluid dynamics: a three-dimensional and particle image velocimetry echo study. Siciliano M, Migliore F, Badano L, Bertaglia E, Pedrizzetti G, Cavedon S, Zorzi A, Corrado D, Iliceto S, Muraru D. Europace; 2017 Nov 01; 19(11):1833-1840. PubMed ID: 28025231 [Abstract] [Full Text] [Related]
7. Left Ventricular Enlargement, Cardiac Resynchronization Therapy Efficacy, and Impact of MultiPoint Pacing. Varma N, Baker J, Tomassoni G, Love CJ, Martin D, Sheppard R, Niazi I, Cranke G, Lee K, Corbisiero R. Circ Arrhythm Electrophysiol; 2020 Nov 01; 13(11):e008680. PubMed ID: 33028082 [Abstract] [Full Text] [Related]
8. Multipoint left ventricular pacing with large anatomical separation improves reverse remodeling and response to cardiac resynchronization therapy in responders and non-responders to conventional biventricular pacing. Schiedat F, Schöne D, Aweimer A, Bösche L, Ewers A, Gotzmann M, Patsalis PC, Mügge A, Kloppe A. Clin Res Cardiol; 2020 Feb 01; 109(2):183-193. PubMed ID: 31152199 [Abstract] [Full Text] [Related]
9. Cardiac resynchronization therapy non-responder to responder conversion rate in the more response to cardiac resynchronization therapy with MultiPoint Pacing (MORE-CRT MPP) study: results from Phase I. Leclercq C, Burri H, Curnis A, Delnoy PP, Rinaldi CA, Sperzel J, Lee K, Calò L, Vicentini A, Concha JF, Thibault B. Eur Heart J; 2019 Sep 14; 40(35):2979-2987. PubMed ID: 30859220 [Abstract] [Full Text] [Related]
10. Multipoint pacing by a left ventricular quadripolar lead improves the acute hemodynamic response to CRT compared with conventional biventricular pacing at any site. Zanon F, Baracca E, Pastore G, Marcantoni L, Fraccaro C, Lanza D, Picariello C, Aggio S, Roncon L, Dell'Avvocata F, Rigatelli G, Pacetta D, Noventa F, Prinzen FW. Heart Rhythm; 2015 May 14; 12(5):975-81. PubMed ID: 25625721 [Abstract] [Full Text] [Related]
12. Rationale and design of a randomized clinical trial to assess the safety and efficacy of multipoint pacing therapy: MOre REsponse on Cardiac Resynchronization Therapy with MultiPoint Pacing (MORE-CRT MPP-PHASE II). Leclercq C, Burri H, Curnis A, Delnoy PP, Rinaldi CA, Sperzel J, Lee K, Cohorn C, Thibault B, MORE-CRT MPP Investigators. Am Heart J; 2019 Mar 14; 209():1-8. PubMed ID: 30616009 [Abstract] [Full Text] [Related]
13. Clinical outcome of left ventricular multipoint pacing versus conventional biventricular pacing in cardiac resynchronization therapy: a systematic review and meta-analysis. Hu F, Zheng L, Ding L, Du Z, Liang E, Wu L, Chen G, Fan X, Yao Y, Jiang Y. Heart Fail Rev; 2018 Nov 14; 23(6):927-934. PubMed ID: 30209643 [Abstract] [Full Text] [Related]
14. Cardiac Resynchronization Therapy Delivered Via a Multipolar Left Ventricular Lead is Associated with Reduced Mortality and Elimination of Phrenic Nerve Stimulation: Long-Term Follow-Up from a Multicenter Registry. Behar JM, Bostock J, Zhu Li AP, Chin HM, Jubb S, Lent E, Gamble J, Foley PW, Betts TR, Rinaldi CA, Herring N. J Cardiovasc Electrophysiol; 2015 May 14; 26(5):540-6. PubMed ID: 25631303 [Abstract] [Full Text] [Related]
15. Long-term reverse remodeling and clinical improvement by MultiPoint Pacing in a randomized, international, Middle Eastern heart failure study. Almusaad A, Sweidan R, Alanazi H, Jamiel A, Bokhari F, Al Hebaishi Y, Al Fagih A, Alrawahi N, Al-Mandalawi A, Hashim M, Al Ghamdi B, Amin M, Elmaghawry M, Al Shoaibi N, Sorgente A, Loricchio M, AlMohani G, Al Abri I, Benjamin E, Sudan N, Chami A, Badie N, Sayed M, Hersi A. J Interv Card Electrophysiol; 2022 Mar 14; 63(2):399-407. PubMed ID: 34156610 [Abstract] [Full Text] [Related]
16. Improvement in acute contractility and hemodynamics with multipoint pacing via a left ventricular quadripolar pacing lead. Rinaldi CA, Leclercq C, Kranig W, Kacet S, Betts T, Bordachar P, Gutleben KJ, Shetty A, Donal E, Keel A, Ryu K, Farazi TG, Simon M, Naqvi TZ. J Interv Card Electrophysiol; 2014 Jun 14; 40(1):75-80. PubMed ID: 24626999 [Abstract] [Full Text] [Related]
18. The use of multisite left ventricular pacing via quadripolar lead improves acute haemodynamics and mechanical dyssynchrony assessed by radial strain speckle tracking: initial results. Osca J, Alonso P, Cano O, Andrés A, Miro V, Tello MJ, Olagüe J, Martínez L, Salvador A. Europace; 2016 Apr 14; 18(4):560-7. PubMed ID: 26333378 [Abstract] [Full Text] [Related]
19. Design and rationale of the Impact of MultiPoint pacing in CRT patients with reduced RV-to-LV delay (IMAGE-CRT) study. Solimene F, Nigro G, Canciello M, Tavoletta V, Shopova G, Calvanese R, Rago A, La Rosa C, Nappi F, Viscusi M, Urraro F, Manzo G, Gallo P, Andriani A, Rovaris G, Palmisano P, Innocenti S, D'Onofrio A. J Cardiovasc Med (Hagerstown); 2020 Mar 14; 21(3):250-258. PubMed ID: 32004245 [Abstract] [Full Text] [Related]