These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


112 related items for PubMed ID: 27225845

  • 1. Hb Grifton [α87(F8)His→Pro; HBA1: C.263A > C (or HBA2)] Causes Abnormal Pulse Oximetry Measurements.
    Waters AM, Caboot JB, Verhovsek MM, Harper DP, Forouhar MA.
    Hemoglobin; 2016 Aug; 40(4):257-9. PubMed ID: 27225845
    [Abstract] [Full Text] [Related]

  • 2. FIRST IDENTIFICATION OF HEMOGLOBIN LANSINGRAMATHIBODI [α87(F8)His → Gln; CAC>CAG (HBA1: c.264C>G)] IN A THAI FAMILY WITH SPURIOUS HYPOXEMIA.
    Trakulsrichai S, Panthan B, Jittorntam P, Niparuck P, Sriapha C, Chantratita W, Wananukul W, Trachoo O.
    Southeast Asian J Trop Med Public Health; 2016 Sep; 47(5):1048-54. PubMed ID: 29620819
    [Abstract] [Full Text] [Related]

  • 3.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 4. Diagnosis and clinical presentation of hemoglobin Kirksey.
    Hitaka D, Arai J.
    Pediatr Int; 2016 Mar; 58(3):235-237. PubMed ID: 26678362
    [Abstract] [Full Text] [Related]

  • 5.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 6. Low oxygen saturation by pulse oximetry may be associated with a low oxygen affinity hemoglobin variant, hemoglobin Titusville.
    Deyell R, Jackson S, Spier S, Le D, Poon MC.
    J Pediatr Hematol Oncol; 2006 Feb; 28(2):100-2. PubMed ID: 16462584
    [Abstract] [Full Text] [Related]

  • 7. Dyshemoglobinemias and pulse oximetry: a therapeutic challenge.
    Hladik A, Lynshue K.
    J Pediatr Hematol Oncol; 2008 Nov; 30(11):850-2. PubMed ID: 18989162
    [Abstract] [Full Text] [Related]

  • 8. Pulse oximetry: understanding its basic principles facilitates appreciation of its limitations.
    Chan ED, Chan MM, Chan MM.
    Respir Med; 2013 Jun; 107(6):789-99. PubMed ID: 23490227
    [Abstract] [Full Text] [Related]

  • 9. Oxygen saturation in pulse oximetry in hemoglobin anomalies.
    Zur B, Bagci S, Ludwig M, Stoffel-Wagner B.
    Klin Padiatr; 2012 Jul; 224(4):259-65. PubMed ID: 22815129
    [Abstract] [Full Text] [Related]

  • 10. A case of Hb Rothschild (HBB: c.112T>A) with low pulse oximetry: a first familial presentation in China.
    Li D, Wan Q, Li C, Ma H, Wang G.
    Hematology; 2022 Dec; 27(1):1204-1207. PubMed ID: 36330781
    [Abstract] [Full Text] [Related]

  • 11. Hemoglobin Denver, a cause of desaturated pulse oximetry. A pediatric case report.
    Rossetti E, Eandi Eberle S, Aguirre F, Pepe C, Díaz L, Harris V, Ávalos V.
    Arch Argent Pediatr; 2023 Oct 01; 121(5):e202202801. PubMed ID: 36857142
    [Abstract] [Full Text] [Related]

  • 12. Haemoglobin Bonn in a Chinese family as a cause of spurious hypoxaemia measured by pulse oximetry.
    So CC, Chan AY, Chow EY, Lin SY, Yip SF, Szeto SC, Chan LC.
    J Clin Pathol; 2010 Oct 01; 63(10):947-9. PubMed ID: 20876330
    [Abstract] [Full Text] [Related]

  • 13. Detection of Hb Rothschild HBB: c.[112T>A or 112T>C], Through High Index of Suspicion on Abnormal Pulse Oximetry.
    Alli NA, Wessels P, Rampersad N, Clark BE, Thein SL.
    Hemoglobin; 2017 Mar 01; 41(2):137-139. PubMed ID: 28621168
    [Abstract] [Full Text] [Related]

  • 14. Accuracy of pulse oximetry in children.
    Ross PA, Newth CJ, Khemani RG.
    Pediatrics; 2014 Jan 01; 133(1):22-9. PubMed ID: 24344108
    [Abstract] [Full Text] [Related]

  • 15. Pulse Oximetry Overestimates Oxyhemoglobin in Neonates with Critical Congenital Heart Disease.
    Murphy D, Pak Y, Cleary JP.
    Neonatology; 2016 Jan 01; 109(3):213-8. PubMed ID: 26800085
    [Abstract] [Full Text] [Related]

  • 16. [Decreasing oxygen saturation detected by pulse oximetry after the administration of isosulfan blue].
    Mateo D, Suescun MC, Cahisa M, Ruiz P, García M, Miranda L.
    Rev Esp Anestesiol Reanim; 2002 Feb 01; 49(2):114-5. PubMed ID: 12025243
    [No Abstract] [Full Text] [Related]

  • 17. Low Oxygen Affinity Variant Haemoglobin in an elderly woman presenting with low oxygen saturation.
    Igbineweka NE, Horne GA, Jackson MB, Chevassut TJ.
    Acute Med; 2015 Feb 01; 14(2):72-6. PubMed ID: 26305085
    [Abstract] [Full Text] [Related]

  • 18. Ten Years of Routine α- and β-Globin Gene Sequencing in UK Hemoglobinopathy Referrals Reveals 60 Novel Mutations.
    Henderson SJ, Timbs AT, McCarthy J, Gallienne AE, Proven M, Rugless MJ, Lopez H, Eglinton J, Dziedzic D, Beardsall M, Khalil MS, Old JM.
    Hemoglobin; 2016 Feb 01; 40(2):75-84. PubMed ID: 26635043
    [Abstract] [Full Text] [Related]

  • 19. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia.
    Feiner JR, Bickler PE, Mannheimer PD.
    Anesth Analg; 2010 Jul 01; 111(1):143-8. PubMed ID: 20007731
    [Abstract] [Full Text] [Related]

  • 20. Validity of pulse oximetry in detection of hypoxaemia in children: comparison of ear, thumb and toe probe placements.
    Bilan N, Behbahan AG, Abdinia B, Mahallei M.
    East Mediterr Health J; 2010 Feb 01; 16(2):218-22. PubMed ID: 20799578
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 6.