These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


231 related items for PubMed ID: 27283321

  • 1. Whole lung morphometry with 3D multiple b-value hyperpolarized gas MRI and compressed sensing.
    Chan HF, Stewart NJ, Parra-Robles J, Collier GJ, Wild JM.
    Magn Reson Med; 2017 May; 77(5):1916-1925. PubMed ID: 27283321
    [Abstract] [Full Text] [Related]

  • 2. 3D diffusion-weighted 129 Xe MRI for whole lung morphometry.
    Chan HF, Stewart NJ, Norquay G, Collier GJ, Wild JM.
    Magn Reson Med; 2018 Jun; 79(6):2986-2995. PubMed ID: 29034509
    [Abstract] [Full Text] [Related]

  • 3. Rapid single-breath hyperpolarized noble gas MRI-based biomarkers of airspace enlargement.
    Westcott A, Guo F, Parraga G, Ouriadov A.
    J Magn Reson Imaging; 2019 Jun; 49(6):1713-1722. PubMed ID: 30578587
    [Abstract] [Full Text] [Related]

  • 4. Lung morphometry using hyperpolarized 129 Xe multi-b diffusion MRI with compressed sensing in healthy subjects and patients with COPD.
    Zhang H, Xie J, Xiao S, Zhao X, Zhang M, Shi L, Wang K, Wu G, Sun X, Ye C, Zhou X.
    Med Phys; 2018 Jul; 45(7):3097-3108. PubMed ID: 29729010
    [Abstract] [Full Text] [Related]

  • 5. Assessment of pulmonary morphometry using hyperpolarized 129 Xe diffusion-weighted MRI with variable-sampling-ratio compressed sensing patterns.
    Zhou Q, Li H, Rao Q, Zhang M, Zhao X, Shen L, Fang Y, Li H, Liu X, Xiao S, Shi L, Han Y, Ye C, Zhou X.
    Med Phys; 2023 Feb; 50(2):867-878. PubMed ID: 36196039
    [Abstract] [Full Text] [Related]

  • 6. Comparison of in vivo lung morphometry models from 3D multiple b-value 3 He and 129 Xe diffusion-weighted MRI.
    Chan HF, Collier GJ, Weatherley ND, Wild JM.
    Magn Reson Med; 2019 May; 81(5):2959-2971. PubMed ID: 30515852
    [Abstract] [Full Text] [Related]

  • 7. Accelerated 129 Xe MRI morphometry of terminal airspace enlargement: Feasibility in volunteers and those with alpha-1 antitrypsin deficiency.
    Ouriadov A, Guo F, McCormack DG, Parraga G.
    Magn Reson Med; 2020 Jul; 84(1):416-426. PubMed ID: 31765497
    [Abstract] [Full Text] [Related]

  • 8. Accelerate gas diffusion-weighted MRI for lung morphometry with deep learning.
    Duan C, Deng H, Xiao S, Xie J, Li H, Zhao X, Han D, Sun X, Lou X, Ye C, Zhou X.
    Eur Radiol; 2022 Jan; 32(1):702-713. PubMed ID: 34255160
    [Abstract] [Full Text] [Related]

  • 9. Compressed sensing in hyperpolarized 3He lung MRI.
    Ajraoui S, Lee KJ, Deppe MH, Parnell SR, Parra-Robles J, Wild JM.
    Magn Reson Med; 2010 Apr; 63(4):1059-69. PubMed ID: 20373407
    [Abstract] [Full Text] [Related]

  • 10. Multiple breath washout of hyperpolarized 129 Xe and 3 He in human lungs with three-dimensional balanced steady-state free-precession imaging.
    Horn FC, Rao M, Stewart NJ, Wild JM.
    Magn Reson Med; 2017 Jun; 77(6):2288-2295. PubMed ID: 27404992
    [Abstract] [Full Text] [Related]

  • 11. Fast dynamic ventilation MRI of hyperpolarized 129 Xe using spiral imaging.
    Doganay O, Matin TN, Mcintyre A, Burns B, Schulte RF, Gleeson FV, Bulte D.
    Magn Reson Med; 2018 May; 79(5):2597-2606. PubMed ID: 28921655
    [Abstract] [Full Text] [Related]

  • 12.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 13.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 14.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 15. Hyperpolarized 3He ventilation defects and apparent diffusion coefficients in chronic obstructive pulmonary disease: preliminary results at 3.0 Tesla.
    Parraga G, Ouriadov A, Evans A, McKay S, Lam WW, Fenster A, Etemad-Rezai R, McCormack D, Santyr G.
    Invest Radiol; 2007 Jun; 42(6):384-91. PubMed ID: 17507809
    [Abstract] [Full Text] [Related]

  • 16. Prospective acceleration of diffusion tensor imaging with compressed sensing using adaptive dictionaries.
    McClymont D, Teh I, Whittington HJ, Grau V, Schneider JE.
    Magn Reson Med; 2016 Jul; 76(1):248-58. PubMed ID: 26302363
    [Abstract] [Full Text] [Related]

  • 17. Application of a stretched-exponential model for morphometric analysis of accelerated diffusion-weighted 129Xe MRI of the rat lung.
    Ouriadov AV, Fox MS, Lindenmaier AA, Stirrat E, Serrai H, Santyr G.
    MAGMA; 2021 Feb; 34(1):73-84. PubMed ID: 32632748
    [Abstract] [Full Text] [Related]

  • 18. High spatial resolution compressed sensing (HSPARSE) functional MRI.
    Fang Z, Van Le N, Choy M, Lee JH.
    Magn Reson Med; 2016 Aug; 76(2):440-55. PubMed ID: 26511101
    [Abstract] [Full Text] [Related]

  • 19. Lung morphometry using hyperpolarized (129) Xe apparent diffusion coefficient anisotropy in chronic obstructive pulmonary disease.
    Ouriadov A, Farag A, Kirby M, McCormack DG, Parraga G, Santyr GE.
    Magn Reson Med; 2013 Dec; 70(6):1699-706. PubMed ID: 23359386
    [Abstract] [Full Text] [Related]

  • 20. Fast and accurate reconstruction of human lung gas MRI with deep learning.
    Duan C, Deng H, Xiao S, Xie J, Li H, Sun X, Ma L, Lou X, Ye C, Zhou X.
    Magn Reson Med; 2019 Dec; 82(6):2273-2285. PubMed ID: 31322298
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 12.