These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


547 related items for PubMed ID: 27286232

  • 1. A 32 mm  ×  32 mm  ×  22 mm monolithic LYSO:Ce detector with dual-sided digital photon counter readout for ultrahigh-performance TOF-PET and TOF-PET/MRI.
    Borghi G, Peet BJ, Tabacchini V, Schaart DR.
    Phys Med Biol; 2016 Jul 07; 61(13):4929-49. PubMed ID: 27286232
    [Abstract] [Full Text] [Related]

  • 2. Towards monolithic scintillator based TOF-PET systems: practical methods for detector calibration and operation.
    Borghi G, Tabacchini V, Schaart DR.
    Phys Med Biol; 2016 Jul 07; 61(13):4904-28. PubMed ID: 27285955
    [Abstract] [Full Text] [Related]

  • 3. Sub-3 mm, near-200 ps TOF/DOI-PET imaging with monolithic scintillator detectors in a 70 cm diameter tomographic setup.
    Borghi G, Tabacchini V, Bakker R, Schaart DR.
    Phys Med Biol; 2018 Jul 27; 63(15):155006. PubMed ID: 29995639
    [Abstract] [Full Text] [Related]

  • 4. Performance of long rectangular semi-monolithic scintillator PET detectors.
    Zhang X, Wang X, Ren N, Hu B, Ding B, Kuang Z, Wu S, Sang Z, Hu Z, Du J, Liang D, Liu X, Zheng H, Yang Y.
    Med Phys; 2019 Apr 27; 46(4):1608-1619. PubMed ID: 30723932
    [Abstract] [Full Text] [Related]

  • 5. A semi-monolithic detector providing intrinsic DOI-encoding and sub-200 ps CRT TOF-capabilities for clinical PET applications.
    Mueller F, Naunheim S, Kuhl Y, Schug D, Solf T, Schulz V.
    Med Phys; 2022 Dec 27; 49(12):7469-7488. PubMed ID: 36259245
    [Abstract] [Full Text] [Related]

  • 6. Sub-millimetre DOI detector based on monolithic LYSO and digital SiPM for a dedicated small-animal PET system.
    Marcinkowski R, Mollet P, Van Holen R, Vandenberghe S.
    Phys Med Biol; 2016 Mar 07; 61(5):2196-2212. PubMed ID: 26907952
    [Abstract] [Full Text] [Related]

  • 7. Side readout of long scintillation crystal elements with digital SiPM for TOF-DOI PET.
    Yeom JY, Vinke R, Levin CS.
    Med Phys; 2014 Dec 07; 41(12):122501. PubMed ID: 25471979
    [Abstract] [Full Text] [Related]

  • 8. An edge-readout, multilayer detector for positron emission tomography.
    Li X, Ruiz-Gonzalez M, Furenlid LR.
    Med Phys; 2018 Jun 07; 45(6):2425-2438. PubMed ID: 29635734
    [Abstract] [Full Text] [Related]

  • 9. Depth-encoding using optical photon TOF in a prism-PET detector with tapered crystals.
    Zeng X, LaBella A, Wang Z, Li Y, Tan W, Goldan AH.
    Med Phys; 2024 Jun 07; 51(6):4044-4055. PubMed ID: 38682574
    [Abstract] [Full Text] [Related]

  • 10. Monolithic scintillator PET detectors with intrinsic depth-of-interaction correction.
    Maas MC, Schaart DR, van der Laan DJ, Bruyndonckx P, Lemaître C, Beekman FJ, van Eijk CW.
    Phys Med Biol; 2009 Apr 07; 54(7):1893-908. PubMed ID: 19265203
    [Abstract] [Full Text] [Related]

  • 11. Depth-of-interaction positron emission tomography detector with 45° tilted silicon photomultipliers using dual-ended signal readout.
    Seo M, Park H, Lee S, Ko GB, Lee JS.
    Med Phys; 2023 Jul 07; 50(7):4112-4121. PubMed ID: 36907664
    [Abstract] [Full Text] [Related]

  • 12. A finely segmented semi-monolithic detector tailored for high-resolution PET.
    Kuhl Y, Mueller F, Naunheim S, Bovelett M, Lambertus J, Schug D, Weissler B, Gegenmantel E, Gebhardt P, Schulz V.
    Med Phys; 2024 May 07; 51(5):3421-3436. PubMed ID: 38214395
    [Abstract] [Full Text] [Related]

  • 13. First characterization of a digital SiPM based time-of-flight PET detector with 1 mm spatial resolution.
    Seifert S, van der Lei G, van Dam HT, Schaart DR.
    Phys Med Biol; 2013 May 07; 58(9):3061-74. PubMed ID: 23587636
    [Abstract] [Full Text] [Related]

  • 14. Wavelength discrimination (WLD) TOF-PET detector with DOI information.
    Ullah MN, Pratiwi E, Park JH, Lee K, Choi H, Yeom JY.
    Phys Med Biol; 2020 Feb 28; 65(5):055003. PubMed ID: 31874462
    [Abstract] [Full Text] [Related]

  • 15.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 16. Simulation study of a brain PET scanner using TOF-DOI detectors equipped with first interaction position detection.
    Li Y, Watanabe M, Isobe T, Ote K, Tokui A, Omura T, Liu H.
    Phys Med Biol; 2022 Dec 22; 68(1):. PubMed ID: 36560889
    [Abstract] [Full Text] [Related]

  • 17. Pushing the limit of BGO-based dual-ended Cherenkov PET detectors through photon transit time correction.
    Yi M, Ko GB, Lee JS.
    Phys Med Biol; 2024 Jan 05; 69(2):. PubMed ID: 38091614
    [Abstract] [Full Text] [Related]

  • 18. A novel, SiPM-array-based, monolithic scintillator detector for PET.
    Schaart DR, van Dam HT, Seifert S, Vinke R, Dendooven P, Löhner H, Beekman FJ.
    Phys Med Biol; 2009 Jun 07; 54(11):3501-12. PubMed ID: 19443953
    [Abstract] [Full Text] [Related]

  • 19. A thick semi-monolithic scintillator detector for clinical PET scanners.
    Zhang C, Wang X, Sun M, Kuang Z, Zhang X, Ren N, Wu S, Sang Z, Sun T, Hu Z, Yang Y, Liu Z.
    Phys Med Biol; 2021 Mar 12; 66(6):065023. PubMed ID: 33709958
    [Abstract] [Full Text] [Related]

  • 20. A time-based double-sided readout concept of 100 mm LYSO:Ce,Ca fibres for future axial TOF-PET.
    Weindel K, Nadig V, Herweg K, Schulz V, Gundacker S.
    EJNMMI Phys; 2023 Jul 14; 10(1):43. PubMed ID: 37450099
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 28.