These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


128 related items for PubMed ID: 27362964

  • 1. Extending laboratory automation to the wards: effect of an innovative pneumatic tube system on diagnostic samples and transport time.
    Suchsland J, Winter T, Greiser A, Streichert T, Otto B, Mayerle J, Runge S, Kallner A, Nauck M, Petersmann A.
    Clin Chem Lab Med; 2017 Feb 01; 55(2):225-230. PubMed ID: 27362964
    [Abstract] [Full Text] [Related]

  • 2. Diagnostic sample transport via pneumatic tube systems: data logger and their algorithms are sensitive to transport effects.
    Ninnemann J, Zylla S, Streichert T, Otto B, Haenel M, Nauck M, Petersmann A.
    Clin Chem Lab Med; 2024 Mar 25; 62(4):657-663. PubMed ID: 37833063
    [Abstract] [Full Text] [Related]

  • 3. Comparison of pneumatic tube system with manual transport for routine chemistry, hematology, coagulation and blood gas tests.
    Pupek A, Matthewson B, Whitman E, Fullarton R, Chen Y.
    Clin Chem Lab Med; 2017 Aug 28; 55(10):1537-1544. PubMed ID: 28432841
    [Abstract] [Full Text] [Related]

  • 4.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 5. Determination of hemolysis thresholds by the use of data loggers in pneumatic tube systems.
    Streichert T, Otto B, Schnabel C, Nordholt G, Haddad M, Maric M, Petersmann A, Jung R, Wagener C.
    Clin Chem; 2011 Oct 28; 57(10):1390-7. PubMed ID: 21836074
    [Abstract] [Full Text] [Related]

  • 6.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 7. Pneumatic tube validation: Reducing the need for donor samples by integrating a vial-embedded data logger.
    Stangerup I, Broell F, Hoop JV, Sennels HP.
    Ann Clin Biochem; 2021 Jul 28; 58(4):280-288. PubMed ID: 33478238
    [Abstract] [Full Text] [Related]

  • 8. Preanalytical influence of pneumatic tube delivery system on results of routine biochemistry and haematology analysis.
    Petit M, Mine L, Pascreau T, Brouzes C, Majoux S, Borgel D, Beaudeux JL, Lasne D, Hennequin C.
    Ann Biol Clin (Paris); 2017 Dec 01; 75(6):703-712. PubMed ID: 29043982
    [Abstract] [Full Text] [Related]

  • 9.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 10. Effect of pneumatic tube transport on T lymphocyte subsets analysis.
    Gossez M, Poitevin-Later F, Demaret J, Jallades L, Venet F, Malcus C, Monneret G.
    Cytometry B Clin Cytom; 2015 Dec 01; 88(6):371-4. PubMed ID: 25665181
    [Abstract] [Full Text] [Related]

  • 11. Evaluation of a pneumatic tube system carrier prototype with fixing mechanism allowing for automated unloading.
    Märtens CM, Schöpfel J, Bollmann S, Hannemann A, Zylla S, Dahl MB, Gauß F, Schedl J, Nauck M, Petersmann A.
    Clin Chem Lab Med; 2022 Jul 26; 60(8):1202-1210. PubMed ID: 35635785
    [Abstract] [Full Text] [Related]

  • 12.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 13. Does Pneumatic Tube System Transport Contribute to Hemolysis in ED Blood Samples?
    Phelan MP, Reineks EZ, Hustey FM, Berriochoa JP, Podolsky SR, Meldon S, Schold JD, Chamberlin J, Procop GW.
    West J Emerg Med; 2016 Sep 26; 17(5):557-60. PubMed ID: 27625719
    [Abstract] [Full Text] [Related]

  • 14. The Effect of Pneumatic Tube Systems on the Hemolysis of Biochemistry Blood Samples.
    Cakirca G, Erdal H.
    J Emerg Nurs; 2017 May 26; 43(3):255-258. PubMed ID: 28359708
    [Abstract] [Full Text] [Related]

  • 15. Evaluation of the BD Vacutainer(®) RST blood collection tube for routine chemistry analytes: clinical significance of differences and stability study.
    Kocijancic M, Cargonja J, Delic-Knezevic A.
    Biochem Med (Zagreb); 2014 May 26; 24(3):368-75. PubMed ID: 25351355
    [Abstract] [Full Text] [Related]

  • 16. Speed of sample transportation by a pneumatic tube system can influence the degree of hemolysis.
    Tiwari AK, Pandey P, Dixit S, Raina V.
    Clin Chem Lab Med; 2011 Nov 10; 50(3):471-4. PubMed ID: 22070350
    [Abstract] [Full Text] [Related]

  • 17. Pneumatic tube-transported blood samples in lithium heparinate gel separator tubes may be more susceptible to haemolysis than blood samples in serum tubes.
    Böckel-Frohnhöfer N, Hübner U, Hummel B, Geisel J.
    Scand J Clin Lab Invest; 2014 Oct 10; 74(7):599-602. PubMed ID: 24909156
    [Abstract] [Full Text] [Related]

  • 18.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 19.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 20. Air bubbles and hemolysis of blood samples during transport by pneumatic tube systems.
    Mullins GR, Bruns DE.
    Clin Chim Acta; 2017 Oct 10; 473():9-13. PubMed ID: 28803746
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 7.