340 related items for PubMed ID: 2741859

  • 1. Pulse oximetry in methemoglobinemia.
    Watcha MF, Connor MT, Hing AV.
    Am J Dis Child; 1989 Jul; 143(7):845-7. PubMed ID: 2741859
    [Abstract] [Full Text] [Related]

  • 2. Laboratory assessment of oxygenation in methemoglobinemia.
    Haymond S, Cariappa R, Eby CS, Scott MG.
    Clin Chem; 2005 Feb; 51(2):434-44. PubMed ID: 15514101
    [Abstract] [Full Text] [Related]

  • 3. Effects of methemoglobinemia on pulse oximetry and mixed venous oximetry.
    Barker SJ, Tremper KK, Hyatt J.
    Anesthesiology; 1989 Jan; 70(1):112-7. PubMed ID: 2912291
    [Abstract] [Full Text] [Related]

  • 4. Methodologic problems encountered with cooximetry in methemoglobinemia.
    Rausch-Madison S, Mohsenifar Z.
    Am J Med Sci; 1997 Sep; 314(3):203-6. PubMed ID: 9298047
    [Abstract] [Full Text] [Related]

  • 5. Absorption spectra of human fetal and adult oxyhemoglobin, de-oxyhemoglobin, carboxyhemoglobin, and methemoglobin.
    Zijlstra WG, Buursma A, Meeuwsen-van der Roest WP.
    Clin Chem; 1991 Sep; 37(9):1633-8. PubMed ID: 1716537
    [Abstract] [Full Text] [Related]

  • 6. Notes on the apparent discordance of pulse oximetry and multi-wavelength haemoglobin photometry.
    Nijland R, Jongsma HW, Nijhuis JG, Oeseburg B, Zijlstra WG.
    Acta Anaesthesiol Scand Suppl; 1995 Sep; 107():49-52. PubMed ID: 8599297
    [Abstract] [Full Text] [Related]

  • 7. Effect of carboxyhemoglobin on the accuracy of mixed venous oximetry monitors in dogs.
    Haney M, Tait AR, Tremper KK.
    Crit Care Med; 1994 Jul; 22(7):1181-5. PubMed ID: 8026210
    [Abstract] [Full Text] [Related]

  • 8. Interpretation of Oxygen Saturation in Congenital Heart Disease: Fact and Fallacy.
    Olsen J, Puri K.
    Pediatr Rev; 2022 Aug 01; 43(8):436-448. PubMed ID: 35909132
    [Abstract] [Full Text] [Related]

  • 9. [Aniline-induced methemoglobinemia monitored by pulse oximetry].
    Kubota M, Soma K, Suzuki M, Hanada N, Takada N, Kusuhara N, Kobayashi H, Yanase N, Abe T, Tomita T.
    Nihon Kyobu Shikkan Gakkai Zasshi; 1993 Jul 01; 31(7):886-9. PubMed ID: 8366629
    [Abstract] [Full Text] [Related]

  • 10. Accuracy of methemoglobin detection by pulse CO-oximetry during hypoxia.
    Feiner JR, Bickler PE, Mannheimer PD.
    Anesth Analg; 2010 Jul 01; 111(1):143-8. PubMed ID: 20007731
    [Abstract] [Full Text] [Related]

  • 11. [Estimation of PaO2 using pulsatile oximetry and the HbO2 dissociation curve in the premature infant].
    Major D, Masson M.
    Union Med Can; 1989 Jul 01; 118(1):18, 21-2. PubMed ID: 2711532
    [Abstract] [Full Text] [Related]

  • 12. Accuracy of pulse oximetry in children with cyanotic congenital heart disease.
    Schmitt HJ, Schuetz WH, Proeschel PA, Jaklin C.
    J Cardiothorac Vasc Anesth; 1993 Feb 01; 7(1):61-5. PubMed ID: 8431577
    [Abstract] [Full Text] [Related]

  • 13. Measurement of carboxyhemoglobin and methemoglobin by pulse oximetry: a human volunteer study.
    Barker SJ, Curry J, Redford D, Morgan S.
    Anesthesiology; 2006 Nov 01; 105(5):892-7. PubMed ID: 17065881
    [Abstract] [Full Text] [Related]

  • 14. A new instrument for the simultaneous measurement of total hemoglobin, % oxyhemoglobin, % carboxyhemoglobin, % methemoglobin, and oxygen content in whole blood.
    Brown LJ.
    IEEE Trans Biomed Eng; 1980 Mar 01; 27(3):132-8. PubMed ID: 7358415
    [No Abstract] [Full Text] [Related]

  • 15. Validation of oxygen saturation monitoring in neonates.
    Shiao SY, Ou CN.
    Am J Crit Care; 2007 Mar 01; 16(2):168-78. PubMed ID: 17322018
    [Abstract] [Full Text] [Related]

  • 16. Relationship of pulse oximetry to arterial oxygen tension in infants.
    Walsh MC, Noble LM, Carlo WA, Martin RJ.
    Crit Care Med; 1987 Dec 01; 15(12):1102-5. PubMed ID: 2445529
    [Abstract] [Full Text] [Related]

  • 17. Transcutaneous monitoring of hemoglobin derivatives during methemoglobinemia in rats using spectral diffuse reflectance.
    Khatun F, Aizu Y, Nishidate I.
    J Biomed Opt; 2021 Feb 01; 26(3):. PubMed ID: 33583153
    [Abstract] [Full Text] [Related]

  • 18. Determination of hemoglobin saturation in patients with acute sickle chest syndrome: a comparison of arterial blood gases and pulse oximetry.
    Kress JP, Pohlman AS, Hall JB.
    Chest; 1999 May 01; 115(5):1316-20. PubMed ID: 10334146
    [Abstract] [Full Text] [Related]

  • 19. Dyshemoglobinemias and pulse oximetry: a therapeutic challenge.
    Hladik A, Lynshue K.
    J Pediatr Hematol Oncol; 2008 Nov 01; 30(11):850-2. PubMed ID: 18989162
    [Abstract] [Full Text] [Related]

  • 20. A novel hemoglobin, Bonn, causes falsely decreased oxygen saturation measurements in pulse oximetry.
    Zur B, Hornung A, Breuer J, Doll U, Bernhardt C, Ludwig M, Stoffel-Wagner B.
    Clin Chem; 2008 Mar 01; 54(3):594-6. PubMed ID: 18310146
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]