These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
23. The effect of uncemented acetabular liner geometry and lip size on the risk of revision for instability or loosening : a study on 202,511 primary hip arthroplasties from the National Joint Registry. Divecha HM, O'Neill TW, Lunt M, Board TN. Bone Joint J; 2021 Dec; 103-B(12):1774-1782. PubMed ID: 34847718 [Abstract] [Full Text] [Related]
25. A biomechanical analysis of polyethylene liner cementation into a fixed metal acetabular shell. Haft GF, Heiner AD, Dorr LD, Brown TD, Callaghan JJ. J Bone Joint Surg Am; 2003 Jun; 85(6):1100-10. PubMed ID: 12784010 [Abstract] [Full Text] [Related]
26. Cementation of polyethylene liners into well-fixed metal shells at the time of revision total hip arthroplasty. Mauerhan DR, Peindl RD, Coley ER, Marshall A. J Arthroplasty; 2008 Sep; 23(6):873-8. PubMed ID: 18534544 [Abstract] [Full Text] [Related]
27. Cementation of a metal-inlay polyethylene liner into a stable metal shell in revision total hip arthroplasty. Yoon TR, Seon JK, Song EK, Chung JY, Seo HY, Park YB. J Arthroplasty; 2005 Aug; 20(5):652-7. PubMed ID: 16310003 [Abstract] [Full Text] [Related]
34. Cementing Multihole, Metal, Modular Acetabular Shells Into Cages in Revision Total Hip Arthroplasty. Bolanos A, Ries M. Am J Orthop (Belle Mead NJ); 2015 Sep; 44(9):425-8. PubMed ID: 26372753 [Abstract] [Full Text] [Related]
35. Deformation and Recovery of Thin Metal-Backed, Two-Piece Polyethylene Acetabular Resurfacing Components. Pritchett J. J Long Term Eff Med Implants; 2019 Sep; 29(1):59-69. PubMed ID: 31679203 [Abstract] [Full Text] [Related]
36. Radiostereometric analysis study of tantalum compared with titanium acetabular cups and highly cross-linked compared with conventional liners in young patients undergoing total hip replacement. Ayers DC, Greene M, Snyder B, Aubin M, Drew J, Bragdon C. J Bone Joint Surg Am; 2015 Apr 15; 97(8):627-34. PubMed ID: 25878306 [Abstract] [Full Text] [Related]
38. Early catastrophic failure of a PINNACLE MARATHON® polyethylene acetabular liner: a report of a malpositioned PINNACLE DUOFIX HA® acetabular shell resulting in point loading and accelerated wear. Hill DS, Patel K, Herlekar D. Hip Int; 2016 Nov 10; 26(6):e52-e55. PubMed ID: 27739572 [Abstract] [Full Text] [Related]
39. Does a titanium-coated polyethylene press-fit cup give reliable midterm results? Hooper N, Sargeant H, Frampton C, Hooper G. Clin Orthop Relat Res; 2015 Dec 10; 473(12):3806-10. PubMed ID: 26373851 [Abstract] [Full Text] [Related]