These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
215 related items for PubMed ID: 27580519
1. Multi-phase passband balanced SSFP fMRI with 50ms sampling rate at 7Tesla enables high precision in resolving 100ms neuronal events. Chen Z, Xue R, Zhang P, Sun K, Zuo Z, An J, Chen J, He S, Chen L, Wang DJJ. Magn Reson Imaging; 2017 Jan; 35():20-28. PubMed ID: 27580519 [Abstract] [Full Text] [Related]
4. Full-brain coverage and high-resolution imaging capabilities of passband b-SSFP fMRI at 3T. Lee JH, Dumoulin SO, Saritas EU, Glover GH, Wandell BA, Nishimura DG, Pauly JM. Magn Reson Med; 2008 May; 59(5):1099-110. PubMed ID: 18421687 [Abstract] [Full Text] [Related]
5. High-resolution mapping of neuronal activation with balanced SSFP at 9.4 tesla. Scheffler K, Ehses P. Magn Reson Med; 2016 Jul; 76(1):163-71. PubMed ID: 26302451 [Abstract] [Full Text] [Related]
6. Multi-echo balanced SSFP with a sequential phase-encoding order for functional MR imaging at 7T. Liang H, Pan Z, Qian C, Liu C, Sun K, Weng D, An J, Zhuo Y, Wang DJJ, Guo H, Xue R. Magn Reson Med; 2022 Sep; 88(3):1303-1313. PubMed ID: 35657055 [Abstract] [Full Text] [Related]
7. Systematic investigation of balanced steady-state free precession for functional MRI in the human visual cortex at 3 Tesla. Zhong K, Leupold J, Hennig J, Speck O. Magn Reson Med; 2007 Jan; 57(1):67-73. PubMed ID: 17191247 [Abstract] [Full Text] [Related]
9. Comparison between multi-shot gradient echo EPI and balanced SSFP in unenhanced 3T MRA of thoracic aorta in healthy volunteers. Iyama Y, Nakaura T, Nagayama Y, Oda S, Utsunomiya D, Kidoh M, Yuki H, Hirata K, Namimoto T, Kitajima M, Morita K, Funama Y, Takemura A, Tokuyasu S, Okuaki T, Yamashita Y. Eur J Radiol; 2017 Nov; 96():85-90. PubMed ID: 29103481 [Abstract] [Full Text] [Related]
10. Signal and noise characteristics of SSFP FMRI: a comparison with GRE at multiple field strengths. Miller KL, Smith SM, Jezzard P, Wiggins GC, Wiggins CJ. Neuroimage; 2007 Oct 01; 37(4):1227-36. PubMed ID: 17706432 [Abstract] [Full Text] [Related]
11. Multi-slice passband bSSFP for human and rodent fMRI at ultra-high field. Reynaud O, da Silva AR, Gruetter R, Jelescu IO. J Magn Reson; 2019 Aug 01; 305():31-40. PubMed ID: 31195214 [Abstract] [Full Text] [Related]
16. Effect of echo spacing and readout bandwidth on basic performances of EPI-fMRI acquisition sequences implemented on two 1.5 T MR scanner systems. Giannelli M, Diciotti S, Tessa C, Mascalchi M. Med Phys; 2010 Jan 01; 37(1):303-10. PubMed ID: 20175493 [Abstract] [Full Text] [Related]
18. Concurrent electrophysiological and hemodynamic measurements of evoked neural oscillations in human visual cortex using sparsely interleaved fast fMRI and EEG. Lee HJ, Huang SY, Kuo WJ, Graham SJ, Chu YH, Stenroos M, Lin FH. Neuroimage; 2020 Aug 15; 217():116910. PubMed ID: 32389729 [Abstract] [Full Text] [Related]
20. Parallel imaging with asymmetric acceleration to reduce Gibbs artifacts and to increase signal-to-noise ratio of the gradient echo echo-planar imaging sequence for functional MRI. Jung KJ, Zhao T. Magn Reson Med; 2012 Feb 15; 67(2):419-27. PubMed ID: 21713976 [Abstract] [Full Text] [Related] Page: [Next] [New Search]