These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
924 related items for PubMed ID: 27697744
1. Ternary nanohybrid of reduced graphene oxide-nafion@silver nanoparticles for boosting the sensor performance in non-enzymatic amperometric detection of hydrogen peroxide. Yusoff N, Rameshkumar P, Mehmood MS, Pandikumar A, Lee HW, Huang NM. Biosens Bioelectron; 2017 Jan 15; 87():1020-1028. PubMed ID: 27697744 [Abstract] [Full Text] [Related]
2. A non-enzymatic amperometric hydrogen peroxide sensor based on iron nanoparticles decorated reduced graphene oxide nanocomposite. Amanulla B, Palanisamy S, Chen SM, Velusamy V, Chiu TW, Chen TW, Ramaraj SK. J Colloid Interface Sci; 2017 Feb 01; 487():370-377. PubMed ID: 27810505 [Abstract] [Full Text] [Related]
4. A novel and facile synthesis of carbon quantum dots via salep hydrothermal treatment as the silver nanoparticles support: Application to electroanalytical determination of H2O2 in fetal bovine serum. Jahanbakhshi M, Habibi B. Biosens Bioelectron; 2016 Jul 15; 81():143-150. PubMed ID: 26943787 [Abstract] [Full Text] [Related]
5. Preparation of gold nanoparticles supported on graphene oxide with flagella as the template for nonenzymatic hydrogen peroxide sensing. Tian C, Zhang S, Zhuang X, Wang H, Chen D, Luan F, He T, He W, Qiu Y. Anal Bioanal Chem; 2018 Sep 15; 410(23):5915-5921. PubMed ID: 29987346 [Abstract] [Full Text] [Related]
8. A novel enzyme-free amperometric sensor for hydrogen peroxide based on Nafion/exfoliated graphene oxide-Co3O4 nanocomposite. Ensafi AA, Jafari-Asl M, Rezaei B. Talanta; 2013 Jan 15; 103():322-9. PubMed ID: 23200394 [Abstract] [Full Text] [Related]
9. A nanocomposite-based electrochemical sensor for non-enzymatic detection of hydrogen peroxide. Du X, Chen Y, Dong W, Han B, Liu M, Chen Q, Zhou J. Oncotarget; 2017 Feb 21; 8(8):13039-13047. PubMed ID: 28035076 [Abstract] [Full Text] [Related]
15. Direct electrochemistry and electrocatalysis of lobetyolin via magnetic functionalized reduced graphene oxide film fabricated electrochemical sensor. Sun B, Gou X, Bai R, Abdelmoaty AAA, Ma Y, Zheng X, Hu F. Mater Sci Eng C Mater Biol Appl; 2017 May 01; 74():515-524. PubMed ID: 28254326 [Abstract] [Full Text] [Related]
17. Non-enzymatic electrochemical hydrogen peroxide biosensor based on reduction graphene oxide-persimmon tannin‑platinum nanocomposite. Huang Y, Xue Y, Zeng J, Li S, Wang Z, Dong C, Li G, Liang J, Zhou Z. Mater Sci Eng C Mater Biol Appl; 2018 Nov 01; 92():590-598. PubMed ID: 30184785 [Abstract] [Full Text] [Related]
18. Electrochemiluminescence of luminol enhanced by the synergetic catalysis of hemin and silver nanoparticles for sensitive protein detection. Jiang X, Chai Y, Wang H, Yuan R. Biosens Bioelectron; 2014 Apr 15; 54():20-6. PubMed ID: 24240164 [Abstract] [Full Text] [Related]
19. Aniline as a dispersing and stabilizing agent for reduced graphene oxide and its subsequent decoration with Ag nanoparticles for enzymeless hydrogen peroxide detection. Liu S, Wang L, Tian J, Luo Y, Zhang X, Sun X. J Colloid Interface Sci; 2011 Nov 15; 363(2):615-9. PubMed ID: 21855890 [Abstract] [Full Text] [Related]
20. 3D Network and 2D Paper of Reduced Graphene Oxide/Cu2O Composite for Electrochemical Sensing of Hydrogen Peroxide. Cheng C, Zhang C, Gao X, Zhuang Z, Du C, Chen W. Anal Chem; 2018 Feb 06; 90(3):1983-1991. PubMed ID: 29286638 [Abstract] [Full Text] [Related] Page: [Next] [New Search]