These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


654 related items for PubMed ID: 27761750

  • 1. Comparison of vascular responses after different types of second-generation drug-eluting stents implantation detected by optical coherence tomography.
    Ohtani H, Kimura S, Sugiyama T, Hishikari K, Misawa T, Mizusawa M, Hayasaka K, Yamakami Y, Kojima K, Sagawa Y, Hikita H, Ashikaga T, Takahashi A, Isobe M.
    Int J Cardiovasc Imaging; 2017 Feb; 33(2):177-186. PubMed ID: 27761750
    [Abstract] [Full Text] [Related]

  • 2. Randomized comparison of acute stent malapposition between platinum-chromium versus cobalt-chromium everolimus-eluting stents.
    Kim BK, Shin DH, Kim JS, Ko YG, Choi D, Jang Y, Hong MK.
    Int J Cardiovasc Imaging; 2015 Feb; 31(2):269-77. PubMed ID: 25345751
    [Abstract] [Full Text] [Related]

  • 3.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 4. The REMEDEE-OCT Study: An Evaluation of the Bioengineered COMBO Dual-Therapy CD34 Antibody-Covered Sirolimus-Eluting Coronary Stent Compared With a Cobalt-Chromium Everolimus-Eluting Stent in Patients With Acute Coronary Syndromes: Insights From Optical Coherence Tomography Imaging Analysis.
    Jaguszewski M, Aloysius R, Wang W, Bezerra HG, Hill J, De Winter RJ, Karjalainen PP, Verheye S, Wijns W, Lüscher TF, Joner M, Costa M, Landmesser U.
    JACC Cardiovasc Interv; 2017 Mar 13; 10(5):489-499. PubMed ID: 28279316
    [Abstract] [Full Text] [Related]

  • 5.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 6. Impact of different stent alloys on human vascular response to everolimus-eluting stent: an optical coherence tomography study: the OCTEVEREST.
    Guagliumi G, Capodanno D, Ikejima H, Bezerra HG, Sirbu V, Musumeci G, Fiocca L, Lortkipanidze N, Vassileva A, Tahara S, Valsecchi O, Costa MA.
    Catheter Cardiovasc Interv; 2013 Feb 13; 81(3):510-8. PubMed ID: 22431208
    [Abstract] [Full Text] [Related]

  • 7. Very early neointimal coverage of new biodegradable polymer drug-eluting stent compared with durable polymer everolimus-eluting stent evaluated by optical frequency domain imaging.
    Kobayashi N, Ito Y, Yamawaki M, Araki M, Sakai T, Sakamoto Y, Mori S, Tsutsumi M, Nauchi M, Honda Y, Tokuda T, Makino K, Shirai S, Hirano K.
    Int J Cardiovasc Imaging; 2018 Apr 13; 34(4):515-522. PubMed ID: 29159531
    [Abstract] [Full Text] [Related]

  • 8. Very early tissue coverage after drug-eluting stent implantation: an optical coherence tomography study.
    Takahara M, Kitahara H, Nishi T, Miura K, Miyayama T, Sugimoto K, Nakayama T, Fujimoto Y, Kobayashi Y.
    Int J Cardiovasc Imaging; 2017 Jan 13; 33(1):25-30. PubMed ID: 27601229
    [Abstract] [Full Text] [Related]

  • 9.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 10. Comparison of early strut coverage between zotarolimus- and everolimus-eluting stents using optical coherence tomography.
    Kim S, Kim JS, Shin DH, Kim BK, Ko YG, Choi D, Cho YK, Nam CW, Hur SH, Jang Y, Hong MK.
    Am J Cardiol; 2013 Jan 01; 111(1):1-5. PubMed ID: 23040589
    [Abstract] [Full Text] [Related]

  • 11.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 12.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 13.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 14. Stent coverage and neointimal proliferation in bare metal stents postdilated with a Paclitaxel-eluting balloon versus everolimus-eluting stents: prospective randomized study using optical coherence tomography at 6-month follow-up.
    Poerner TC, Otto S, Gassdorf J, Nitsche K, Janiak F, Scheller B, Goebel B, Jung C, Figulla HR.
    Circ Cardiovasc Interv; 2014 Dec 01; 7(6):760-7. PubMed ID: 25371536
    [Abstract] [Full Text] [Related]

  • 15. Neointimal coverage of zotarolimus-eluting stent at 1, 2, and 3 months' follow-up: an optical coherence tomography study.
    Hashikata T, Tojo T, Namba S, Kitasato L, Hashimoto T, Kameda R, Shimohama T, Yamaoka-Tojo M, Ako J.
    Heart Vessels; 2016 Feb 01; 31(2):206-11. PubMed ID: 25362579
    [Abstract] [Full Text] [Related]

  • 16.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 17. Serial assessment of vessel interactions after drug-eluting stent implantation in unprotected distal left main coronary artery disease using frequency-domain optical coherence tomography.
    Fujino Y, Attizzani GF, Bezerra HG, Wang W, Tahara S, Yamamoto H, Chamie D, Kanaya T, Mehanna E, Takagi K, Nakamura S, Costa MA.
    JACC Cardiovasc Interv; 2013 Oct 01; 6(10):1035-45. PubMed ID: 24156964
    [Abstract] [Full Text] [Related]

  • 18. ComparisOn of neointimal coVerage betwEen zotaRolimus-eluting stent and everolimus-eluting stent using Optical Coherence Tomography (COVER OCT).
    Kim JS, Kim BK, Jang IK, Shin DH, Ko YG, Choi D, Hong MK, Cho YK, Nam CW, Hur SH, Choi JH, Song YB, Hahn JY, Choi SH, Gwon HC, Jang Y.
    Am Heart J; 2012 Apr 01; 163(4):601-7. PubMed ID: 22520526
    [Abstract] [Full Text] [Related]

  • 19. Favorable neointimal coverage in everolimus-eluting stent at 9 months after stent implantation: comparison with sirolimus-eluting stent using optical coherence tomography.
    Choi HH, Kim JS, Yoon DH, Hong KS, Kim TH, Kim BK, Ko YG, Choi D, Jang Y, Hong MK.
    Int J Cardiovasc Imaging; 2012 Mar 01; 28(3):491-7. PubMed ID: 21442265
    [Abstract] [Full Text] [Related]

  • 20. Comparison of in-stent neoatherosclerosis and tissue characteristics between early and late in-stent restenosis in second-generation drug-eluting stents: an optical coherence tomography study.
    Sabbah M, Kadota K, El-Eraky A, Kamal HM, Abdellah AT, El Hawary A.
    Int J Cardiovasc Imaging; 2017 Oct 01; 33(10):1463-1472. PubMed ID: 28444549
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 33.