These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
154 related items for PubMed ID: 27827492
1. Label/quencher-free detection of single-nucleotide changes in DNA using isothermal amplification and G-quadruplexes. Lee IJ, Goo NI, Kim DE. Analyst; 2016 Nov 28; 141(24):6503-6506. PubMed ID: 27827492 [Abstract] [Full Text] [Related]
2. Fluorometric Detection of Low-Abundance EGFR Exon 19 Deletion Mutation Using Tandem Gene Amplification. Kim DM, Zhang S, Kim M, Kim DE. J Microbiol Biotechnol; 2020 May 28; 30(5):662-667. PubMed ID: 32482931 [Abstract] [Full Text] [Related]
3. Label-free and highly sensitive APE1 detection based on rolling circle amplification combined with G-quadruplex. Liu B, Yang Z, Huang T, Li MM, Duan W, Xie B, Chen JX, Dai Z, Chen J. Talanta; 2022 Jul 01; 244():123404. PubMed ID: 35349840 [Abstract] [Full Text] [Related]
4. Ultrasensitive fluorescent detection of nucleic acids based on label-free enzymatic-assisted cascade signal amplification. Qin Y, Liao S, Huang Y, Zhao J, Zhao S. Anal Chim Acta; 2018 Dec 18; 1039():91-97. PubMed ID: 30322557 [Abstract] [Full Text] [Related]
5. Label-free fluorometric detection of microRNA using isothermal rolling circle amplification generating tandem G-quadruplex. Kim M, Kim DM, Kim DE. Analyst; 2020 Sep 14; 145(18):6130-6137. PubMed ID: 32869779 [Abstract] [Full Text] [Related]
6. A label-free fluorescent turn-on enzymatic amplification assay for DNA detection using ligand-responsive G-quadruplex formation. Zhao C, Wu L, Ren J, Qu X. Chem Commun (Camb); 2011 May 21; 47(19):5461-3. PubMed ID: 21483972 [Abstract] [Full Text] [Related]
7. Label-free fluorescent biosensor based on the target recycling and Thioflavin T-induced quadruplex formation for short DNA species of c-erbB-2 detection. Chen J, Lin J, Zhang X, Cai S, Wu D, Li C, Yang S, Zhang J. Anal Chim Acta; 2014 Mar 19; 817():42-7. PubMed ID: 24594816 [Abstract] [Full Text] [Related]
8. A highly sensitive label-free sensor for Mercury ion (Hg²⁺) by inhibiting thioflavin T as DNA G-quadruplexes fluorescent inducer. Ge J, Li XP, Jiang JH, Yu RQ. Talanta; 2014 May 19; 122():85-90. PubMed ID: 24720966 [Abstract] [Full Text] [Related]
9. Engineering of a DNAzyme-Based dimeric G-quadruplex rolling circle amplification for robust analysis of lead ion. Peng Y, Xue P, Chen W, Xu J. Talanta; 2024 Jul 01; 274():126029. PubMed ID: 38599120 [Abstract] [Full Text] [Related]
10. Sensitive fluorescent detection of DNA methyltransferase using nicking endonuclease-mediated multiple primers-like rolling circle amplification. Huang J, Li XY, Du YC, Zhang LN, Liu KK, Zhu LN, Kong DM. Biosens Bioelectron; 2017 May 15; 91():417-423. PubMed ID: 28063390 [Abstract] [Full Text] [Related]
11. Label-free thioflavin T/G-quadruplex-based real-time strand displacement amplification for biosensing applications. Du YC, Zhu LN, Kong DM. Biosens Bioelectron; 2016 Dec 15; 86():811-817. PubMed ID: 27479048 [Abstract] [Full Text] [Related]
12. Ultrasensitive fluorescence detection of nucleic acids using exonuclease III-induced cascade two-stage isothermal amplification-mediated zinc (II)-protoporphyrin IX/G-quadruplex supramolecular fluorescent nanotags. Xue Q, Lv Y, Zhang Y, Xu S, Li R, Yue Q, Li H, Wang L, Gu X, Zhang S, Liu J. Biosens Bioelectron; 2014 Nov 15; 61():351-6. PubMed ID: 24912035 [Abstract] [Full Text] [Related]
13. Amplified and multiplexed detection of DNA using the dendritic rolling circle amplified synthesis of DNAzyme reporter units. Wang F, Lu CH, Liu X, Freage L, Willner I. Anal Chem; 2014 Feb 04; 86(3):1614-21. PubMed ID: 24377284 [Abstract] [Full Text] [Related]
14. Label-Free Telomerase Detection in Single Cell Using a Five-Base Telomerase Product-Triggered Exponential Rolling Circle Amplification Strategy. Li X, Cui Y, Du Y, Tang A, Kong D. ACS Sens; 2019 Apr 26; 4(4):1090-1096. PubMed ID: 30945529 [Abstract] [Full Text] [Related]
15. G-quadruplex based two-stage isothermal exponential amplification reaction for label-free DNA colorimetric detection. Nie J, Zhang DW, Tie C, Zhou YL, Zhang XX. Biosens Bioelectron; 2014 Jun 15; 56():237-42. PubMed ID: 24508547 [Abstract] [Full Text] [Related]
16. Toehold-mediated strand displacement reaction triggered isothermal DNA amplification for highly sensitive and selective fluorescent detection of single-base mutation. Zhu J, Ding Y, Liu X, Wang L, Jiang W. Biosens Bioelectron; 2014 Sep 15; 59():276-81. PubMed ID: 24742973 [Abstract] [Full Text] [Related]
17. A Thioflavin T-induced G-Quadruplex Fluorescent Biosensor for Target DNA Detection. Zhang XF, Xu HM, Han L, Li NB, Luo HQ. Anal Sci; 2018 Sep 15; 34(2):149-153. PubMed ID: 29434099 [Abstract] [Full Text] [Related]
18. Entropy-Driven Catalytic G-Quadruple Cycle Amplification Integrated with Ligases for Label-Free Detection of Single Nucleotide Polymorphisms. Zhang Y, Yang F, Huang T, Xu S, Ye J, Weng L, Hu Y, Huang H, Li S, Zhang D. Anal Chem; 2024 Sep 17; 96(37):14971-14979. PubMed ID: 39213531 [Abstract] [Full Text] [Related]
19. Label-free and highly sensitive electrochemical detection of E. coli based on rolling circle amplifications coupled peroxidase-mimicking DNAzyme amplification. Guo Y, Wang Y, Liu S, Yu J, Wang H, Wang Y, Huang J. Biosens Bioelectron; 2016 Jan 15; 75():315-9. PubMed ID: 26334590 [Abstract] [Full Text] [Related]