These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
133 related items for PubMed ID: 27910528
1. Compact and multi-view solid state neutral particle analyzer arrays on National Spherical Torus Experiment-Upgrade. Liu D, Heidbrink WW, Tritz K, Fredrickson ED, Hao GZ, Zhu YB. Rev Sci Instrum; 2016 Nov; 87(11):11D803. PubMed ID: 27910528 [Abstract] [Full Text] [Related]
2. Design of solid state neutral particle analyzer array for National Spherical Torus Experiment-Upgrade. Liu D, Heidbrink WW, Tritz K, Zhu YB, Roquemore AL, Medley SS. Rev Sci Instrum; 2014 Nov; 85(11):11E105. PubMed ID: 25430284 [Abstract] [Full Text] [Related]
3. Installation of a solid state neutral particle analyzer array on mega ampere spherical tokamak upgrade. Prechel G, Fil N, Liu D, Heidbrink WW, Michael C, Jackson AR, MAST-U TeamUniversity of California Irvine, Irvine, California 92697, USAUKAEA Fusion Association, Culham Science Centre, Abingdon, Oxfordshire OX14 3DB, United KingdomGeneral Atomics, San Diego, California 92186, USAUniversity of California, Los Angeles, California 90095, USAUniversity of Durham, South Road, Durham DH1 3LE, United Kingdom.. Rev Sci Instrum; 2022 Nov 01; 93(11):113517. PubMed ID: 36461446 [Abstract] [Full Text] [Related]
4. Compact solid-state neutral particle analyzer in current mode. Zhu YB, Bortolon A, Heidbrink WW, Celle SL, Roquemore AL. Rev Sci Instrum; 2012 Oct 01; 83(10):10D304. PubMed ID: 23126831 [Abstract] [Full Text] [Related]
5. First results from solid state neutral particle analyzer on experimental advanced superconducting tokamak. Zhang JZ, Zhu YB, Zhao JL, Wan BN, Li JG, Heidbrink WW. Rev Sci Instrum; 2016 Nov 01; 87(11):11D834. PubMed ID: 27910466 [Abstract] [Full Text] [Related]
6. Studying fast-ion populations using oscillations in solid-state neutral-particle analyzer signal and neutral-beam injection power. Parr E, McClements KG, Heidbrink WW, Michael CA, Prechel G, Rivero-Rodriguez JF, MAST-U Team. Rev Sci Instrum; 2024 Jan 01; 95(1):. PubMed ID: 38230994 [Abstract] [Full Text] [Related]
7. Development of an integrated energetic neutral particle measurement system on experimental advanced full superconducting tokamak. Zhu YB, Zhang JZ, Qi MZ, Xia SB, Liu D, Heidbrink WW, Wan BN, Li JG. Rev Sci Instrum; 2014 Nov 01; 85(11):11E107. PubMed ID: 25430286 [Abstract] [Full Text] [Related]
9. A new compact solid-state neutral particle analyser at ASDEX Upgrade: Setup and physics modeling. Schneider PA, Blank H, Geiger B, Mank K, Martinov S, Ryter F, Weiland M, Weller A, ASDEX Upgrade Team. Rev Sci Instrum; 2015 Jul 01; 86(7):073508. PubMed ID: 26233384 [Abstract] [Full Text] [Related]
10. Active fast ion charge exchange measurements using a neutral particle analyzer and multiple beam species in C-2W. Kamio S, Granstedt EM, Clary R, Player G, Korepanov S, TAE TeamTAE Technologies, Foothill Ranch, California 92697, USA.. Rev Sci Instrum; 2022 Oct 01; 93(10):103516. PubMed ID: 36319394 [Abstract] [Full Text] [Related]
11. Overview of the beam emission spectroscopy diagnostic system on the National Spherical Torus Experiment. Smith DR, Feder H, Feder R, Fonck RJ, Labik G, McKee GR, Schoenbeck N, Stratton BC, Uzun-Kaymak I, Winz G. Rev Sci Instrum; 2010 Oct 01; 81(10):10D717. PubMed ID: 21033910 [Abstract] [Full Text] [Related]
12. An initial measurement of a fast neutral spectrum for ion cyclotron range of frequency heated plasma using two-channel compact neutral particle analyzers in KSTAR. Kim SH, Wang SJ, Park M, Kim SK. Rev Sci Instrum; 2013 Nov 01; 84(11):113504. PubMed ID: 24289396 [Abstract] [Full Text] [Related]
13. Measurements with magnetic field in the National Spherical Torus Experiment using the motional Stark effect with laser induced fluorescence diagnostic. Foley EL, Levinton FM. Rev Sci Instrum; 2013 Apr 01; 84(4):043110. PubMed ID: 23635184 [Abstract] [Full Text] [Related]
14. Core-ion temperature measurement of the ADITYA tokamak using passive charge exchange neutral particle energy analyzer. Pandya SP, Ajay K, Mishra P, Dhingra RD, Govindarajan J. Rev Sci Instrum; 2013 Feb 01; 84(2):023503. PubMed ID: 23464207 [Abstract] [Full Text] [Related]
15. Design of a retarding potential grid system for a neutral particle analyzer. Titus JB, Anderson JK, Reusch JA, Mezonlin ED. Rev Sci Instrum; 2014 Nov 01; 85(11):11D402. PubMed ID: 25430165 [Abstract] [Full Text] [Related]
16. Development and signals simulation of a diamond detector neutral particle analyzer on Huanliu-2A (HL-2A) tokamak. Qu YF, Zang LG, Chen W, Hou YM, Lu J, Luo Y. Rev Sci Instrum; 2022 Nov 01; 93(11):113507. PubMed ID: 36461440 [Abstract] [Full Text] [Related]
17. Diagnostic performance of the beam emission spectroscopy system on the National Spherical Torus Experiment. Smith DR, Fonck RJ, McKee GR, Thompson DS. Rev Sci Instrum; 2012 Oct 01; 83(10):10D502. PubMed ID: 23126846 [Abstract] [Full Text] [Related]
18. Design and simulation of an imaging neutral particle analyzer for the ASDEX Upgrade tokamak. Rueda-Rueda J, García-Muñoz M, Viezzer E, Schneider PA, García-Domínguez J, Ayllon-Guerola J, Galdón-Quiroga J, Herrmann A, Du XD, Van Zeeland MA, Oyola P, Rodriguez-Ramos M, ASDEX Upgrade TeamDepartment of Atomic, Molecular and Nuclear Physics, Av. Reina Mercedes s/n, 41012Seville, SpainCentro Nacional de Aceleradores (CNA) CSIC, 41092 Seville, SpainMax Planck Institute for Plasma Physics, Boltzmannstr. 2, 85748 Garching, GermanyGeneral Atomics, P.O. Box 85608, San Diego, California 92186-5608, USALaboratory for Ion Beam Interactions, Ruđer Bošković Institute, 10000 Zagreb, Croatia.. Rev Sci Instrum; 2021 Apr 01; 92(4):043554. PubMed ID: 34243403 [Abstract] [Full Text] [Related]
19. Time-resolved ion energy distribution measurements using an advanced neutral particle analyzer on the MST reversed-field pinch. Eilerman S, Anderson JK, Reusch JA, Liu D, Fiksel G, Polosatkin S, Belykh V. Rev Sci Instrum; 2012 Oct 01; 83(10):10D302. PubMed ID: 23126829 [Abstract] [Full Text] [Related]
20. New millimeter-wave diagnostics to locally probe internal density and magnetic field fluctuations in National Spherical Torus Experiment-Upgrade (invited). Macwan T, Barada K, Kubota S, Lantsov R, Bradley L, Pratt Q, Hong R, Michael CA, Hall-Chen V, Wisniewski J, Dong J, Stratton B, Crocker NA, Peebles WA, Rhodes TL. Rev Sci Instrum; 2024 Aug 01; 95(8):. PubMed ID: 39136651 [Abstract] [Full Text] [Related] Page: [Next] [New Search]