1. Probing and Tapping: Are We Inserting Pedicle Screws Correctly? Prasad V, Mesfin A, Lee R, Reigrut J, Schmidt J. Spine Deform; 2016 Nov; 4(6):395-399. PubMed ID: 27927567 [Abstract] [Full Text] [Related]
4. Finding the right fit: studying the biomechanics of under-tapping with varying thread depths and pitches. Jazini E, Petraglia C, Moldavsky M, Tannous O, Weir T, Saifi C, Elkassabany O, Cai Y, Bucklen B, O'Brien J, Ludwig SC. Spine J; 2017 Apr; 17(4):574-578. PubMed ID: 27916685 [Abstract] [Full Text] [Related]
5. Pullout strength of different pedicle screws after primary and revision insertion: an in vitro study on polyurethane foam. Wu LC, Hsieh YY, Tsuang FY, Kuo YJ, Chen CH, Chiang CJ. BMC Musculoskelet Disord; 2023 Nov 07; 24(1):863. PubMed ID: 37932751 [Abstract] [Full Text] [Related]
7. Pullout strength for cannulated pedicle screws with bone cement augmentation in severely osteoporotic bone: influences of radial hole and pilot hole tapping. Chen LH, Tai CL, Lai PL, Lee DM, Tsai TT, Fu TS, Niu CC, Chen WJ. Clin Biomech (Bristol); 2009 Oct 07; 24(8):613-8. PubMed ID: 19481845 [Abstract] [Full Text] [Related]
11. Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method. Renner SM, Lim TH, Kim WJ, Katolik L, An HS, Andersson GB. Spine (Phila Pa 1976); 2004 Jun 01; 29(11):E212-6. PubMed ID: 15167670 [Abstract] [Full Text] [Related]
13. Characteristics of immediate and fatigue strength of a dual-threaded pedicle screw in cadaveric spines. Brasiliense LB, Lazaro BC, Reyes PM, Newcomb AG, Turner JL, Crandall DG, Crawford NR. Spine J; 2013 Aug 01; 13(8):947-56. PubMed ID: 23602373 [Abstract] [Full Text] [Related]
14. The effect of pilot hole size on the insertion torque and pullout strength of self-tapping cortical bone screws in osteoporotic bone. Battula S, Schoenfeld AJ, Sahai V, Vrabec GA, Tank J, Njus GO. J Trauma; 2008 Apr 01; 64(4):990-5. PubMed ID: 18404066 [Abstract] [Full Text] [Related]
17. Biomechanical properties of pedicle screw fixation augmented with allograft bone particles in osteoporotic vertebrae: different sizes and amounts. Jia C, Zhang R, Xing T, Gao H, Li H, Dong F, Zhang J, Ge P, Song P, Xu P, Zhang H, Shen C. Spine J; 2019 Aug 01; 19(8):1443-1452. PubMed ID: 31009768 [Abstract] [Full Text] [Related]
18. A novel bone cement injector augments Chinese osteoporotic lumbar pedicle screw channel: a biomechanical investigation. Fu S, Zhang Y, Ai F, Wang J, Wu Z, Ma X, Wu Z, Wang Z, Lei W, Xia H. BMC Musculoskelet Disord; 2022 Apr 12; 23(1):353. PubMed ID: 35413830 [Abstract] [Full Text] [Related]