These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


202 related items for PubMed ID: 27927567

  • 1. Probing and Tapping: Are We Inserting Pedicle Screws Correctly?
    Prasad V, Mesfin A, Lee R, Reigrut J, Schmidt J.
    Spine Deform; 2016 Nov; 4(6):395-399. PubMed ID: 27927567
    [Abstract] [Full Text] [Related]

  • 2.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 3.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 4. Finding the right fit: studying the biomechanics of under-tapping with varying thread depths and pitches.
    Jazini E, Petraglia C, Moldavsky M, Tannous O, Weir T, Saifi C, Elkassabany O, Cai Y, Bucklen B, O'Brien J, Ludwig SC.
    Spine J; 2017 Apr; 17(4):574-578. PubMed ID: 27916685
    [Abstract] [Full Text] [Related]

  • 5. Pullout strength of different pedicle screws after primary and revision insertion: an in vitro study on polyurethane foam.
    Wu LC, Hsieh YY, Tsuang FY, Kuo YJ, Chen CH, Chiang CJ.
    BMC Musculoskelet Disord; 2023 Nov 07; 24(1):863. PubMed ID: 37932751
    [Abstract] [Full Text] [Related]

  • 6.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 7. Pullout strength for cannulated pedicle screws with bone cement augmentation in severely osteoporotic bone: influences of radial hole and pilot hole tapping.
    Chen LH, Tai CL, Lai PL, Lee DM, Tsai TT, Fu TS, Niu CC, Chen WJ.
    Clin Biomech (Bristol); 2009 Oct 07; 24(8):613-8. PubMed ID: 19481845
    [Abstract] [Full Text] [Related]

  • 8.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 9.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 10.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 11. Augmentation of pedicle screw fixation strength using an injectable calcium phosphate cement as a function of injection timing and method.
    Renner SM, Lim TH, Kim WJ, Katolik L, An HS, Andersson GB.
    Spine (Phila Pa 1976); 2004 Jun 01; 29(11):E212-6. PubMed ID: 15167670
    [Abstract] [Full Text] [Related]

  • 12.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 13. Characteristics of immediate and fatigue strength of a dual-threaded pedicle screw in cadaveric spines.
    Brasiliense LB, Lazaro BC, Reyes PM, Newcomb AG, Turner JL, Crandall DG, Crawford NR.
    Spine J; 2013 Aug 01; 13(8):947-56. PubMed ID: 23602373
    [Abstract] [Full Text] [Related]

  • 14. The effect of pilot hole size on the insertion torque and pullout strength of self-tapping cortical bone screws in osteoporotic bone.
    Battula S, Schoenfeld AJ, Sahai V, Vrabec GA, Tank J, Njus GO.
    J Trauma; 2008 Apr 01; 64(4):990-5. PubMed ID: 18404066
    [Abstract] [Full Text] [Related]

  • 15.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 16.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 17. Biomechanical properties of pedicle screw fixation augmented with allograft bone particles in osteoporotic vertebrae: different sizes and amounts.
    Jia C, Zhang R, Xing T, Gao H, Li H, Dong F, Zhang J, Ge P, Song P, Xu P, Zhang H, Shen C.
    Spine J; 2019 Aug 01; 19(8):1443-1452. PubMed ID: 31009768
    [Abstract] [Full Text] [Related]

  • 18. A novel bone cement injector augments Chinese osteoporotic lumbar pedicle screw channel: a biomechanical investigation.
    Fu S, Zhang Y, Ai F, Wang J, Wu Z, Ma X, Wu Z, Wang Z, Lei W, Xia H.
    BMC Musculoskelet Disord; 2022 Apr 12; 23(1):353. PubMed ID: 35413830
    [Abstract] [Full Text] [Related]

  • 19.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 20.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 11.