These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


3752 related items for PubMed ID: 28003607

  • 1. [Examination for Effectiveness of Scatter Correction in Portable Chest Radiography].
    Ichikawa H, Ono T, Sawane Y, Terabe M, Yamaguchi M, Shimada H.
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2016; 72(12):1207-1215. PubMed ID: 28003607
    [Abstract] [Full Text] [Related]

  • 2. [Usefulness of Post-processing Scatter Correction in Portable Abdominal Radiography Using a Low Ratio Anti-scatter Grid].
    Ichikawa H, Yamada Y, Sawane Y, Terabe M, Ono T, Nishikawa M, Yamaguchi M, Shimada H.
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2019; 75(9):885-891. PubMed ID: 31548465
    [Abstract] [Full Text] [Related]

  • 3. ITERATIVE SCATTER CORRECTION FOR GRID-LESS BEDSIDE CHEST RADIOGRAPHY: PERFORMANCE FOR A CHEST PHANTOM.
    Mentrup D, Jockel S, Menser B, Neitzel U.
    Radiat Prot Dosimetry; 2016 Jun; 169(1-4):308-12. PubMed ID: 26487750
    [Abstract] [Full Text] [Related]

  • 4. Comparison of scatter rejection and low-contrast performance of scan equalization digital radiography (SEDR), slot-scan digital radiography, and full-field digital radiography systems for chest phantom imaging.
    Liu X, Shaw CC, Lai CJ, Wang T.
    Med Phys; 2011 Jan; 38(1):23-33. PubMed ID: 21361171
    [Abstract] [Full Text] [Related]

  • 5. Evaluation of dose reduction potential in scatter-corrected bedside chest radiography using U-net.
    Onodera S, Lee Y, Tanaka Y.
    Radiol Phys Technol; 2020 Dec; 13(4):336-347. PubMed ID: 32986183
    [Abstract] [Full Text] [Related]

  • 6. Digital selenium radiography: anti-scatter grid for chest radiography in a clinical study.
    Bernhardt TM, Rapp-Bernhardt U, Hausmann T, Reichel G, Krause UW, Doehring W.
    Br J Radiol; 2000 Sep; 73(873):963-8. PubMed ID: 11064649
    [Abstract] [Full Text] [Related]

  • 7. Investigation of optimum anti-scatter grid selection for digital radiography: physical imaging properties and detectability of low-contrast signals.
    Tanaka N, Naka K, Saito A, Morishita J, Toyofuku F, Ohki M, Higashida Y.
    Radiol Phys Technol; 2013 Jan; 6(1):54-60. PubMed ID: 22872419
    [Abstract] [Full Text] [Related]

  • 8. [Usefulness of Combining Post-processing Scatter Correction and an Anti-scatter Grid in Chest Standing Radiography].
    Fujikawa K, Osaki T, Nakagawa H, Kikuchi K, Kiriki M, Wada Y, Miki R, Kotoura N.
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2021 Jan; 77(6):555-563. PubMed ID: 34148897
    [Abstract] [Full Text] [Related]

  • 9. Scatter-reduction characteristics of an infinity-focused gridded radiographic cassette.
    Floyd CE, Chotas HG, Ravin CE.
    Invest Radiol; 1994 Sep; 29(9):852-5. PubMed ID: 7995706
    [Abstract] [Full Text] [Related]

  • 10. Effectiveness of antiscatter grids in digital radiography. A phantom study.
    Shaw CC, Wang T, Gur D.
    Invest Radiol; 1994 Jun; 29(6):636-42. PubMed ID: 8088973
    [Abstract] [Full Text] [Related]

  • 11.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 12. Rejection and redistribution of scattered radiation in scan equalization digital radiography (SEDR): simulation with spot images.
    Liu X, Shaw CC.
    Med Phys; 2007 Jul; 34(7):2718-29. PubMed ID: 17821980
    [Abstract] [Full Text] [Related]

  • 13.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 14. Improved image quality of cone beam CT scans for radiotherapy image guidance using fiber-interspaced antiscatter grid.
    Stankovic U, van Herk M, Ploeger LS, Sonke JJ.
    Med Phys; 2014 Jun; 41(6):061910. PubMed ID: 24877821
    [Abstract] [Full Text] [Related]

  • 15. Guidelines for anti-scatter grid use in pediatric digital radiography.
    Fritz S, Jones AK.
    Pediatr Radiol; 2014 Mar; 44(3):313-21. PubMed ID: 24281685
    [Abstract] [Full Text] [Related]

  • 16. [Invention of Optical Sight in Mobile Radiography with Anti-scatter Grid].
    Nakano T.
    Nihon Hoshasen Gijutsu Gakkai Zasshi; 2019 Mar; 75(12):1420-1425. PubMed ID: 31866640
    [Abstract] [Full Text] [Related]

  • 17. Impact of Software Parameter Settings on Image Quality of Virtual Grid Processed Radiography Images: A Contrast-Detail Phantom Study.
    Gossye T, Smeets PV, Achten E, Bacher K.
    Invest Radiol; 2020 Jun; 55(6):374-380. PubMed ID: 31985603
    [Abstract] [Full Text] [Related]

  • 18.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 19. Scatter rejection and low-contrast performance of a slot-scan digital chest radiography system with electronic aft-collimation: a chest phantom study.
    Liu X, Shaw CC, Lai CJ, Altunbas MC, Chen L, Han T, Wang T.
    Med Phys; 2008 Jun; 35(6):2391-402. PubMed ID: 18649472
    [Abstract] [Full Text] [Related]

  • 20.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 188.