These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
55 related items for PubMed ID: 2806797
21. [Value and limitations of transthoracic Doppler echocardiography in the diagnosis of thromboses of mechanical valve prosthesis. Report of 19 cases]. Roudaut R, Gosse P, Basto L, Reynaud P, Leherissier A, Dallocchio M. Arch Mal Coeur Vaiss; 1990 Aug; 83(9):1417-22. PubMed ID: 2122860 [Abstract] [Full Text] [Related]
23. Echocardiographic features of the normofunctional Labcor-Santiago pericardial bioprosthesis. Gonzalez-Juanatey JR, Garcia-Bengoechea JB, Vega M, Rubio J, Sierra J, Duran D, Amaro A, Gil M. J Heart Valve Dis; 1994 Sep; 3(5):548-55. PubMed ID: 8000591 [Abstract] [Full Text] [Related]
24. [The echocardiographic assessment of wall regurgitant jets in prosthetic mitral valves: the superiority of multiplanar transesophageal sections over standard sections]. Bobadilla JF, García-Fernández MA, Moreno M, Garrido P, Torrecilla EG, San Román DJ, Sousa RC, Bermejo J, Delcán JL. Rev Esp Cardiol; 1995 Mar; 48(3):176-82. PubMed ID: 7701098 [Abstract] [Full Text] [Related]
25. [Evaluation of new pericardial bioprostheses by pulsed and continuous Doppler ultrasound ]. Lesbre JP, Chassat C, Lespérance J, Petitclerc R, Bonan R, Dyrda I, Pasternac A, Bourassa M. Arch Mal Coeur Vaiss; 1986 Sep; 79(10):1439-48. PubMed ID: 3099678 [Abstract] [Full Text] [Related]
26. Regurgitant jet size by transesophageal compared with transthoracic Doppler color flow imaging. Smith MD, Harrison MR, Pinton R, Kandil H, Kwan OL, DeMaria AN. Circulation; 1991 Jan; 83(1):79-86. PubMed ID: 1984901 [Abstract] [Full Text] [Related]
27. [Clinical and hemodynamic sequelae of mitral prostheses evaluated by Doppler echocardiography]. Iwahashi K, Ota T, Sato H, Kanda H, Sugimoto T, Okada M, Nakamura K. J Cardiol; 1992 Jan; 22(4):651-9. PubMed ID: 1343631 [Abstract] [Full Text] [Related]
28. Detection of prosthetic mitral valve leak: a comparative study using transesophageal echocardiography, transthoracic echocardiography, and auscultation. Chen YT, Kan MN, Chen JS, Lin WW, Chang MK, Hu WS, Hwang DS, Lee DY, Hwang SL, Chiang BN. J Clin Ultrasound; 1990 Sep; 18(7):557-61. PubMed ID: 2170454 [Abstract] [Full Text] [Related]
29. Regurgitant flow in cardiac valve prostheses: diagnostic value of gradient echo nuclear magnetic resonance imaging in reference to transesophageal two-dimensional color Doppler echocardiography. Deutsch HJ, Bachmann R, Sechtem U, Curtius JM, Jungehülsing M, Schicha H, Hilger HH. J Am Coll Cardiol; 1992 Jun; 19(7):1500-7. PubMed ID: 1593045 [Abstract] [Full Text] [Related]
30. [Effect of prosthesis type and size on the hemodynamic response of mitral valve prostheses to exertion]. Alonso AM, Belló MC. Rev Med Univ Navarra; 1996 Jun; 40(3):19-26. PubMed ID: 9499822 [Abstract] [Full Text] [Related]
31. [Evaluation by Doppler echocardiography of hemodynamic profil of mitral bileaflet prothesis. Report on 90 cases]. Drissa H, Ben Salah F, Zaouali RM. Tunis Med; 2004 Jul; 82(7):648-55. PubMed ID: 15552022 [Abstract] [Full Text] [Related]
32. Characterization of normal leakage flow of monostrut tilting disk prosthetic mitral valves by multiplane transesophageal echocardiography. Temesvari A, Mohl W, Kupilik N. J Am Soc Echocardiogr; 1997 Mar; 10(2):155-8. PubMed ID: 9083971 [Abstract] [Full Text] [Related]
33. [Evaluation with Doppler echocardiography of the Bjork-Shiley Monostrut prosthesis in the mitral position]. Mori F, Zuppiroli A, Favilli S, Ciaccheri M, Minneci C, Alajmo G. G Ital Cardiol; 1990 Oct; 20(10):955-61. PubMed ID: 2090535 [Abstract] [Full Text] [Related]
34. [The usefulness of transesophageal echocardiography in assessing mechanical mitral prostheses. A comparison with transthoracic echocardiography]. González Alujas MT, García del Castillo H, Evangelista Masip A, Candell Riera J, Soler Soler J. Rev Esp Cardiol; 1993 Jul; 46(7):407-12. PubMed ID: 8341826 [Abstract] [Full Text] [Related]
35. Doppler echocardiographic evaluation of prosthetic valves in tricuspid position. Aoyagi S, Tomoeda H, Kawano H, Yokose S, Fukunaga S. Asian Cardiovasc Thorac Ann; 2003 Sep; 11(3):193-7. PubMed ID: 14514546 [Abstract] [Full Text] [Related]
36. [Effects of depth on the display of color Doppler flow imaging with transesophageal and transthoracic transducers: an experimental study]. Harada M, Imamura Y, Hasegawa N, Yano K, Suzuki M, Nishizawa S, Hirai H, Machii K. J Cardiol Suppl; 1991 Sep; 26():3-11, discussion 12-3. PubMed ID: 1930889 [Abstract] [Full Text] [Related]
37. Noninvasive diagnostic evaluation of the normal Beall mitral prosthesis. Smith RA, Kerber RE, Snyder JW. Cathet Cardiovasc Diagn; 1976 Sep; 2(3):289-95. PubMed ID: 991265 [Abstract] [Full Text] [Related]
38. Pitfalls in the display of color Doppler jet areas: combined variability due to Doppler angle, frame rate, and scanning direction. Utsunomiya T, Ogawa T, King SW, Sunada E, Lobodzinski SM, Henry WL, Gardin JM. Echocardiography; 1990 Nov; 7(6):739-45. PubMed ID: 10149216 [Abstract] [Full Text] [Related]
39. Transesophageal echocardiography in valvular heart disease. Karalis DG, Ross JJ, Brown BM, Chandrasekaran K. Cardiovasc Clin; 1993 Nov; 23():105-23. PubMed ID: 8416119 [No Abstract] [Full Text] [Related]
40. [The Duromedics mitral valve mechanical prosthesis: evaluation by means of transesophageal echocardiography]. Desideri A, Dreysse S, Schartl M. G Ital Cardiol; 1989 Aug; 19(8):680-5. PubMed ID: 2806797 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]