615 related items for PubMed ID: 28105711
1. A gate evaluation of the sources of error in quantitative90 Y PET. Strydhorst J, Carlier T, Dieudonné A, Conti M, Buvat I. Med Phys; 2016 Oct; 43(10):5320-5329. PubMed ID: 28105711 [Abstract] [Full Text] [Related]
3. (90)Y -PET imaging: Exploring limitations and accuracy under conditions of low counts and high random fraction. Carlier T, Willowson KP, Fourkal E, Bailey DL, Doss M, Conti M. Med Phys; 2015 Jul; 42(7):4295-309. PubMed ID: 26133627 [Abstract] [Full Text] [Related]
4. Monte Carlo simulation of PET and SPECT imaging of 90Y. Takahashi A, Himuro K, Yamashita Y, Komiya I, Baba S, Sasaki M. Med Phys; 2015 Apr; 42(4):1926-35. PubMed ID: 25832083 [Abstract] [Full Text] [Related]
9. Quantitative and Qualitative Improvement of Low-Count [68Ga]Citrate and [90Y]Microspheres PET Image Reconstructions Using Block Sequential Regularized Expectation Maximization Algorithm. Seo Y, Khalighi MM, Wangerin KA, Deller TW, Wang YH, Jivan S, Kohi MP, Aggarwal R, Flavell RR, Behr SC, Evans MJ. Mol Imaging Biol; 2020 Feb; 22(1):208-216. PubMed ID: 30993558 [Abstract] [Full Text] [Related]
10. Influence of photon energy cuts on PET Monte Carlo simulation results. Mitev K, Gerganov G, Kirov AS, Schmidtlein CR, Madzhunkov Y, Kawrakow I. Med Phys; 2012 Jul; 39(7):4175-86. PubMed ID: 22830751 [Abstract] [Full Text] [Related]
11. PET optimization for improved assessment and accurate quantification of 90Y-microsphere biodistribution after radioembolization. Martí-Climent JM, Prieto E, Elosúa C, Rodríguez-Fraile M, Domínguez-Prado I, Vigil C, García-Velloso MJ, Arbizu J, Peñuelas I, Richter JA. Med Phys; 2014 Sep; 41(9):092503. PubMed ID: 25186412 [Abstract] [Full Text] [Related]
12. Validation of GATE Monte Carlo simulations of the GE Advance/Discovery LS PET scanners. Schmidtlein CR, Kirov AS, Nehmeh SA, Erdi YE, Humm JL, Amols HI, Bidaut LM, Ganin A, Stearns CW, McDaniel DL, Hamacher KA. Med Phys; 2006 Jan; 33(1):198-208. PubMed ID: 16485426 [Abstract] [Full Text] [Related]
15. Investigating the limits of PET/CT imaging at very low true count rates and high random fractions in ion-beam therapy monitoring. Kurz C, Bauer J, Conti M, Guérin L, Eriksson L, Parodi K. Med Phys; 2015 Jul; 42(7):3979-91. PubMed ID: 26133598 [Abstract] [Full Text] [Related]
19. Impact of reconstruction parameters on quantitative I-131 SPECT. van Gils CA, Beijst C, van Rooij R, de Jong HW. Phys Med Biol; 2016 Jul 21; 61(14):5166-82. PubMed ID: 27352225 [Abstract] [Full Text] [Related]