These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


370 related items for PubMed ID: 28238587

  • 21. Direct quantification of mitral regurgitant flow volume by real-time three-dimensional echocardiography using dealiasing of color Doppler flow at the vena contracta.
    Plicht B, Kahlert P, Goldwasser R, Janosi RA, Hunold P, Erbel R, Buck T.
    J Am Soc Echocardiogr; 2008 Dec; 21(12):1337-46. PubMed ID: 19041578
    [Abstract] [Full Text] [Related]

  • 22. Three-dimensional versus two-dimensional echocardiographic assessment of functional mitral regurgitation proximal isovelocity surface area.
    Ashikhmina E, Shook D, Cobey F, Bollen B, Fox J, Liu X, Worthington A, Song P, Shernan S.
    Anesth Analg; 2015 Mar; 120(3):534-542. PubMed ID: 25166465
    [Abstract] [Full Text] [Related]

  • 23. Three-dimensional color Doppler echocardiographic quantification of tricuspid regurgitation orifice area: comparison with conventional two-dimensional measures.
    Chen TE, Kwon SH, Enriquez-Sarano M, Wong BF, Mankad SV.
    J Am Soc Echocardiogr; 2013 Oct; 26(10):1143-1152. PubMed ID: 23993694
    [Abstract] [Full Text] [Related]

  • 24. Quantification of mitral regurgitation by real time three-dimensional color Doppler flow echocardiography pre- and post-percutaneous mitral valve repair.
    Gruner C, Herzog B, Bettex D, Felix C, Datta S, Greutmann M, Gaemperli O, Müggler SA, Tanner FC, Gruenenfelder J, Corti R, Biaggi P.
    Echocardiography; 2015 Jul; 32(7):1140-6. PubMed ID: 25327820
    [Abstract] [Full Text] [Related]

  • 25. Quantification of regurgitation in mitral valve prolapse with automated real time echocardiographic 3D proximal isovelocity surface area: multimodality consistency and role of eccentricity index.
    Spampinato RA, Lindemann F, Jahnke C, Paetsch I, Fahr F, Sieg F, von Roeder M, Noack T, Hilbert S, Löbe S, Strotdrees E, Hindricks G, Borger MA.
    Int J Cardiovasc Imaging; 2021 Jun; 37(6):1947-1959. PubMed ID: 33616785
    [Abstract] [Full Text] [Related]

  • 26. Proximal flow convergence method by three-dimensional color Doppler echocardiography for mitral valve area assessment in rheumatic mitral stenosis.
    de Agustin JA, Mejia H, Viliani D, Marcos-Alberca P, Gomez de Diego JJ, Nuñez-Gil IJ, Almeria C, Rodrigo JL, Luaces M, Garcia-Fernandez MA, Macaya C, Perez de Isla L.
    J Am Soc Echocardiogr; 2014 Aug; 27(8):838-45. PubMed ID: 24909790
    [Abstract] [Full Text] [Related]

  • 27. Diagnostic value of vena contracta area in the quantification of mitral regurgitation severity by color Doppler 3D echocardiography.
    Zeng X, Levine RA, Hua L, Morris EL, Kang Y, Flaherty M, Morgan NV, Hung J.
    Circ Cardiovasc Imaging; 2011 Sep; 4(5):506-13. PubMed ID: 21730026
    [Abstract] [Full Text] [Related]

  • 28.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 29.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 30.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 31.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 32.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 33. Quantitation of valve regurgitation severity by three-dimensional vena contracta area is superior to flow convergence method of quantitation on transesophageal echocardiography.
    Abudiab MM, Chao CJ, Liu S, Naqvi TZ.
    Echocardiography; 2017 Jul; 34(7):992-1001. PubMed ID: 28480555
    [Abstract] [Full Text] [Related]

  • 34.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 35.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 36. Comparison of two- and three-dimensional transthoracic echocardiography to cardiac magnetic resonance imaging for assessment of paravalvular regurgitation after transcatheter aortic valve implantation.
    Altiok E, Frick M, Meyer CG, Al Ateah G, Napp A, Kirschfink A, Almalla M, Lotfi S, Becker M, Herich L, Lehmacher W, Hoffmann R.
    Am J Cardiol; 2014 Jun 01; 113(11):1859-66. PubMed ID: 24837265
    [Abstract] [Full Text] [Related]

  • 37. Comparison of orifice area by transthoracic three-dimensional Doppler echocardiography versus proximal isovelocity surface area (PISA) method for assessment of mitral regurgitation.
    Iwakura K, Ito H, Kawano S, Okamura A, Kurotobi T, Date M, Inoue K, Fujii K.
    Am J Cardiol; 2006 Jun 01; 97(11):1630-7. PubMed ID: 16728228
    [Abstract] [Full Text] [Related]

  • 38. Application of three-dimensional proximal isovelocity surface area method in tricuspid regurgitation quantification.
    Wang BY, Li L, Zhou D, Zhang M.
    Echocardiography; 2019 Jul 01; 36(7):1315-1321. PubMed ID: 31246345
    [Abstract] [Full Text] [Related]

  • 39. Quantitative Evaluation of Mitral Regurgitation Secondary to Mitral Valve Prolapse by Magnetic Resonance Imaging and Echocardiography.
    Le Goffic C, Toledano M, Ennezat PV, Binda C, Castel AL, Delelis F, Graux P, Tribouilloy C, Maréchaux S.
    Am J Cardiol; 2015 Nov 01; 116(9):1405-10. PubMed ID: 26372213
    [Abstract] [Full Text] [Related]

  • 40. Three-dimensional characteristics of functional mitral regurgitation in patients with severe left ventricular dysfunction: a real-time three-dimensional colour Doppler echocardiography study.
    Song JM, Kim MJ, Kim YJ, Kang SH, Kim JJ, Kang DH, Song JK.
    Heart; 2008 May 01; 94(5):590-6. PubMed ID: 17646193
    [Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]
    of 19.