These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


286 related items for PubMed ID: 28274714

  • 1. Quantification of Multiple Mitral Regurgitant Jets: An In Vitro Validation Study Comparing Two- and Three-Dimensional Proximal Isovelocity Surface Area Methods.
    Zürcher F, Brugger N, Jahren SE, de Marchi SF, Seiler C.
    J Am Soc Echocardiogr; 2017 May; 30(5):511-521. PubMed ID: 28274714
    [Abstract] [Full Text] [Related]

  • 2. Quantification of chronic functional mitral regurgitation by automated 3-dimensional peak and integrated proximal isovelocity surface area and stroke volume techniques using real-time 3-dimensional volume color Doppler echocardiography: in vitro and clinical validation.
    Thavendiranathan P, Liu S, Datta S, Rajagopalan S, Ryan T, Igo SR, Jackson MS, Little SH, De Michelis N, Vannan MA.
    Circ Cardiovasc Imaging; 2013 Jan 01; 6(1):125-33. PubMed ID: 23223636
    [Abstract] [Full Text] [Related]

  • 3. Proximal isovelocity surface area by single-beat three-dimensional color Doppler echocardiography applied for tricuspid regurgitation quantification.
    de Agustin JA, Viliani D, Vieira C, Islas F, Marcos-Alberca P, Gomez de Diego JJ, Nuñez-Gil IJ, Almeria C, Rodrigo JL, Luaces M, Garcia-Fernandez MA, Macaya C, Perez de Isla L.
    J Am Soc Echocardiogr; 2013 Sep 01; 26(9):1063-72. PubMed ID: 23860094
    [Abstract] [Full Text] [Related]

  • 4. Direct measurement of proximal isovelocity surface area by single-beat three-dimensional color Doppler echocardiography in mitral regurgitation: a validation study.
    de Agustín JA, Marcos-Alberca P, Fernandez-Golfin C, Gonçalves A, Feltes G, Nuñez-Gil IJ, Almeria C, Rodrigo JL, Perez de Isla L, Macaya C, Zamorano J.
    J Am Soc Echocardiogr; 2012 Aug 01; 25(8):815-23. PubMed ID: 22739217
    [Abstract] [Full Text] [Related]

  • 5. Comparison of three-dimensional proximal isovelocity surface area to cardiac magnetic resonance imaging for quantifying mitral regurgitation.
    Brugger N, Wustmann K, Hürzeler M, Wahl A, de Marchi SF, Steck H, Zürcher F, Seiler C.
    Am J Cardiol; 2015 Apr 15; 115(8):1130-6. PubMed ID: 25747111
    [Abstract] [Full Text] [Related]

  • 6. In vitro validation of real-time three-dimensional color Doppler echocardiography for direct measurement of proximal isovelocity surface area in mitral regurgitation.
    Little SH, Igo SR, Pirat B, McCulloch M, Hartley CJ, Nosé Y, Zoghbi WA.
    Am J Cardiol; 2007 May 15; 99(10):1440-7. PubMed ID: 17493476
    [Abstract] [Full Text] [Related]

  • 7. Validation of Semiautomated Quantification of Mitral Valve Regurgitation by Three-Dimensional Color Doppler Transesophageal Echocardiography.
    Militaru S, Bonnefous O, Hami K, Langet H, Houard L, Allaire S, Pouleur AC, Dianis S, This A, Beauloye C, Vancraeynest D, Pasquet A, Vanoverschelde JL, Gerber BL.
    J Am Soc Echocardiogr; 2020 Mar 15; 33(3):342-354. PubMed ID: 32143780
    [Abstract] [Full Text] [Related]

  • 8. Three-Dimensional Field Optimization Method: Clinical Validation of a Novel Color Doppler Method for Quantifying Mitral Regurgitation.
    Tan TC, Zeng X, Jiao Y, Wang L, Wei Q, Thiele K, Salgo I, Mehta V, Andrawes M, Picard MH, Hung J.
    J Am Soc Echocardiogr; 2016 Oct 15; 29(10):926-934. PubMed ID: 27405591
    [Abstract] [Full Text] [Related]

  • 9. Differential effect of 3-dimensional color Doppler echocardiography for the quantification of mitral regurgitation according to the severity and characteristics.
    Choi J, Heo R, Hong GR, Chang HJ, Sung JM, Shin SH, Cho IJ, Shim CY, Chung N.
    Circ Cardiovasc Imaging; 2014 May 15; 7(3):535-44. PubMed ID: 24700692
    [Abstract] [Full Text] [Related]

  • 10. Three-Dimensional Field Optimization Method: Gold-Standard Validation of a Novel Color Doppler Method for Quantifying Mitral Regurgitation.
    Pierce EL, Rabbah JP, Thiele K, Wei Q, Vidakovic B, Jensen MO, Hung J, Yoganathan AP.
    J Am Soc Echocardiogr; 2016 Oct 15; 29(10):917-925. PubMed ID: 27354250
    [Abstract] [Full Text] [Related]

  • 11. Direct measurement of proximal isovelocity surface area by real-time three-dimensional color Doppler for quantitation of aortic regurgitant volume: an in vitro validation.
    Pirat B, Little SH, Igo SR, McCulloch M, Nosé Y, Hartley CJ, Zoghbi WA.
    J Am Soc Echocardiogr; 2009 Mar 15; 22(3):306-13. PubMed ID: 19168322
    [Abstract] [Full Text] [Related]

  • 12. Clinical Implications of Three-Dimensional Real-Time Color Doppler Transthoracic Echocardiography in Quantifying Mitral Regurgitation: A Comparison with Conventional Two-Dimensional Methods.
    Heo R, Son JW, Ó Hartaigh B, Chang HJ, Kim YJ, Datta S, Cho IJ, Shim CY, Hong GR, Ha JW, Chung N.
    J Am Soc Echocardiogr; 2017 Apr 15; 30(4):393-403.e7. PubMed ID: 28238587
    [Abstract] [Full Text] [Related]

  • 13. Three-dimensional versus two-dimensional echocardiographic assessment of functional mitral regurgitation proximal isovelocity surface area.
    Ashikhmina E, Shook D, Cobey F, Bollen B, Fox J, Liu X, Worthington A, Song P, Shernan S.
    Anesth Analg; 2015 Mar 15; 120(3):534-542. PubMed ID: 25166465
    [Abstract] [Full Text] [Related]

  • 14. Direct quantification of mitral regurgitant flow volume by real-time three-dimensional echocardiography using dealiasing of color Doppler flow at the vena contracta.
    Plicht B, Kahlert P, Goldwasser R, Janosi RA, Hunold P, Erbel R, Buck T.
    J Am Soc Echocardiogr; 2008 Dec 15; 21(12):1337-46. PubMed ID: 19041578
    [Abstract] [Full Text] [Related]

  • 15. In Vitro Quantification of Mitral Regurgitation of Complex Geometry by the Modified Proximal Isovelocity Surface Area Method.
    Papolla C, Adda J, Rique A, Habib G, Rieu R.
    J Am Soc Echocardiogr; 2020 Jul 15; 33(7):838-847.e1. PubMed ID: 32418654
    [Abstract] [Full Text] [Related]

  • 16. Quantitation of valve regurgitation severity by three-dimensional vena contracta area is superior to flow convergence method of quantitation on transesophageal echocardiography.
    Abudiab MM, Chao CJ, Liu S, Naqvi TZ.
    Echocardiography; 2017 Jul 15; 34(7):992-1001. PubMed ID: 28480555
    [Abstract] [Full Text] [Related]

  • 17. Quantitative assessment of primary mitral regurgitation using left ventricular volumes obtained with new automated three-dimensional transthoracic echocardiographic software: A comparison with 3-Tesla cardiac magnetic resonance.
    Levy F, Marechaux S, Iacuzio L, Schouver ED, Castel AL, Toledano M, Rusek S, Dor V, Tribouilloy C, Dreyfus G.
    Arch Cardiovasc Dis; 2018 Jul 15; 111(8-9):507-517. PubMed ID: 29610031
    [Abstract] [Full Text] [Related]

  • 18. A Novel Approach for Semiautomated Three-Dimensional Quantification of Mitral Regurgitant Volume Reflects a More Physiologic Approach to Mitral Regurgitation.
    Singh A, Su J, This A, Allaire S, Rouet JM, Laghi A, Kebed K, Addetia K, Schreckenberg M, Lang RM, Bonnefous O.
    J Am Soc Echocardiogr; 2022 Sep 15; 35(9):940-946. PubMed ID: 35605896
    [Abstract] [Full Text] [Related]

  • 19. Geometry of the proximal isovelocity surface area in mitral regurgitation by 3-dimensional color Doppler echocardiography: difference between functional mitral regurgitation and prolapse regurgitation.
    Matsumura Y, Fukuda S, Tran H, Greenberg NL, Agler DA, Wada N, Toyono M, Thomas JD, Shiota T.
    Am Heart J; 2008 Feb 15; 155(2):231-8. PubMed ID: 18215591
    [Abstract] [Full Text] [Related]

  • 20. Assessment of mitral regurgitation by 3-dimensional proximal flow convergence using magnetic resonance imaging: comparison with echo-Doppler.
    Gorodisky L, Agmon Y, Porat M, Abadi S, Lessick J.
    Int J Cardiovasc Imaging; 2018 May 15; 34(5):793-802. PubMed ID: 29260346
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 15.