These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


353 related items for PubMed ID: 28292729

  • 1. Pre-analytical effects of pneumatic tube system transport on routine haematology and coagulation tests, global coagulation assays and platelet function assays.
    Le Quellec S, Paris M, Nougier C, Sobas F, Rugeri L, Girard S, Bordet JC, Négrier C, Dargaud Y.
    Thromb Res; 2017 May; 153():7-13. PubMed ID: 28292729
    [Abstract] [Full Text] [Related]

  • 2. Pneumatic tube transport of blood samples affects global hemostasis and platelet function assays.
    Lorenzen H, Frøstrup AB, Larsen AS, Fenger MS, Dahdouh S, Zoel-Ghina R, Nielsen LK.
    Int J Lab Hematol; 2021 Oct; 43(5):1207-1215. PubMed ID: 33538112
    [Abstract] [Full Text] [Related]

  • 3. Pneumatic tube system transport does not alter platelet function in optical and whole blood aggregometry, prothrombin time, activated partial thromboplastin time, platelet count and fibrinogen in patients on anti-platelet drug therapy.
    Enko D, Mangge H, Münch A, Niedrist T, Mahla E, Metzler H, Prüller F.
    Biochem Med (Zagreb); 2017 Feb 15; 27(1):217-224. PubMed ID: 28392742
    [Abstract] [Full Text] [Related]

  • 4.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 5.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 6.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 7. Effect of acceleration forces during transport through a pneumatic tube system on ROTEM® analysis.
    Amann G, Zehntner C, Marti F, Colucci G.
    Clin Chem Lab Med; 2012 Mar 09; 50(8):1335-42. PubMed ID: 22868797
    [Abstract] [Full Text] [Related]

  • 8. Impact of a pneumatic tube system transport on hemostasis parameters measurement: the experiment of Cochin universitary hospital (AP-HP, Paris, France).
    Calmette L, Ibrahim F, Gouin I, Horellou MH, Mazoyer É, Fontenay M, Flaujac C.
    Ann Biol Clin (Paris); 2017 Feb 01; 75(1):93-100. PubMed ID: 28132949
    [Abstract] [Full Text] [Related]

  • 9. The Modern Pneumatic Tube System Transports with Reduced Speed Does Not Affect Special Coagulation Tests.
    Slavík L, Úlehlová J, Bradáčová P, Chasáková K, Hluší A, Palová M, Entrová A.
    J Med Syst; 2020 Jul 21; 44(9):142. PubMed ID: 32696269
    [Abstract] [Full Text] [Related]

  • 10. Perioperative monitoring of primary and secondary hemostasis in coronary artery bypass grafting.
    Hertfelder HJ, Bös M, Weber D, Winkler K, Hanfland P, Preusse CJ.
    Semin Thromb Hemost; 2005 Jul 21; 31(4):426-40. PubMed ID: 16149021
    [Abstract] [Full Text] [Related]

  • 11. Pre-analytical effects of pneumatic tube transport on impedance platelet aggregometry.
    Bolliger D, Seeberger MD, Tanaka KA, Dell-Kuster S, Gregor M, Zenklusen U, Grapow M, Tsakiris DA, Filipovic M.
    Platelets; 2009 Nov 21; 20(7):458-65. PubMed ID: 19852683
    [Abstract] [Full Text] [Related]

  • 12. Preanalytical influence of pneumatic tube delivery system on results of routine biochemistry and haematology analysis.
    Petit M, Mine L, Pascreau T, Brouzes C, Majoux S, Borgel D, Beaudeux JL, Lasne D, Hennequin C.
    Ann Biol Clin (Paris); 2017 Dec 01; 75(6):703-712. PubMed ID: 29043982
    [Abstract] [Full Text] [Related]

  • 13. Falsely decreased FVIII activity following pneumatic tube transport.
    Wang H, Wang L, Liang H, Wei J, Wu Y, Wang X, Xu J.
    Int J Lab Hematol; 2021 Apr 01; 43(2):305-310. PubMed ID: 33058454
    [Abstract] [Full Text] [Related]

  • 14. Alterations in rotation thromboelastometry (ROTEM®) parameters: point-of-care testing vs analysis after pneumatic tube system transport.
    Martin J, Schuster T, Moessmer G, Kochs EF, Wagner KJ.
    Br J Anaesth; 2012 Oct 01; 109(4):540-5. PubMed ID: 22767647
    [Abstract] [Full Text] [Related]

  • 15. Laboratory-based ROTEM(®) analysis: implementing pneumatic tube transport and real-time graphic transmission.
    Colucci G, Giabbani E, Barizzi G, Urwyler N, Alberio L.
    Int J Lab Hematol; 2011 Aug 01; 33(4):441-6. PubMed ID: 21382181
    [Abstract] [Full Text] [Related]

  • 16. Pneumatic tube transport affects platelet function measured by multiplate electrode aggregometry.
    Thalén S, Forsling I, Eintrei J, Söderblom L, Antovic JP.
    Thromb Res; 2013 Jul 01; 132(1):77-80. PubMed ID: 23706534
    [Abstract] [Full Text] [Related]

  • 17. Sample transport by pneumatic tube system alters results of multiple electrode aggregometry but not rotational thromboelastometry.
    Glas M, Mauer D, Kassas H, Volk T, Kreuer S.
    Platelets; 2013 Jul 01; 24(6):454-61. PubMed ID: 22931353
    [Abstract] [Full Text] [Related]

  • 18. Comparison of pneumatic tube system with manual transport for routine chemistry, hematology, coagulation and blood gas tests.
    Pupek A, Matthewson B, Whitman E, Fullarton R, Chen Y.
    Clin Chem Lab Med; 2017 Aug 28; 55(10):1537-1544. PubMed ID: 28432841
    [Abstract] [Full Text] [Related]

  • 19. Investigation of the effects of pneumatic tube transport system on routine biochemistry, hematology, and coagulation tests in Ankara City Hospital.
    Yurt EF, Akbiyik F, Bicer C.
    Clin Chem Lab Med; 2022 Apr 26; 60(5):707-713. PubMed ID: 35167733
    [Abstract] [Full Text] [Related]

  • 20. The Effects of Sample Transport by Pneumatic Tube System on Routine Hematology and Coagulation Tests.
    Subbarayan D, Choccalingam C, Lakshmi CKA.
    Adv Hematol; 2018 Apr 26; 2018():6940152. PubMed ID: 30079089
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 18.