These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


207 related items for PubMed ID: 28645085

  • 1. Extending the functionality of the slurry ferrihydrite-DGT method: Performance evaluation for the measurement of vanadate, arsenate, antimonate and molybdate in water.
    Zhang S, Williams PN, Zhou CY, Ma LQ, Luo J.
    Chemosphere; 2017 Oct; 184():812-819. PubMed ID: 28645085
    [Abstract] [Full Text] [Related]

  • 2. An evaluation of ferrihydrite- and Metsorb™-DGT techniques for measuring oxyanion species (As, Se, V, P): effective capacity, competition and diffusion coefficients.
    Price HL, Teasdale PR, Jolley DF.
    Anal Chim Acta; 2013 Nov 25; 803():56-65. PubMed ID: 24216197
    [Abstract] [Full Text] [Related]

  • 3. Performance characteristics of diffusive gradients in thin films equipped with a binding gel layer containing precipitated ferrihydrite for measuring arsenic(V), selenium(VI), vanadium(V), and antimony(V).
    Luo J, Zhang H, Santner J, Davison W.
    Anal Chem; 2010 Nov 01; 82(21):8903-9. PubMed ID: 20936784
    [Abstract] [Full Text] [Related]

  • 4. Simultaneous measurements of As, Mo, Sb, V and W using a ferrihydrite diffusive gradients in thin films (DGT) device.
    Osterlund H, Chlot S, Faarinen M, Widerlund A, Rodushkin I, Ingri J, Baxter DC.
    Anal Chim Acta; 2010 Dec 03; 682(1-2):59-65. PubMed ID: 21056715
    [Abstract] [Full Text] [Related]

  • 5. Simultaneous measurement of trace metal and oxyanion concentrations in water using diffusive gradients in thin films with a Chelex-Metsorb mixed binding layer.
    Panther JG, Bennett WW, Welsh DT, Teasdale PR.
    Anal Chem; 2014 Jan 07; 86(1):427-34. PubMed ID: 24251902
    [Abstract] [Full Text] [Related]

  • 6.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 7.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 8. Selective sampling and measurement of Cr (VI) in water with polyquaternary ammonium salt as a binding agent in diffusive gradients in thin-films technique.
    Chen H, Zhang YY, Zhong KL, Guo LW, Gu JL, Bo L, Zhang MH, Li JR.
    J Hazard Mater; 2014 Apr 30; 271():160-5. PubMed ID: 24632368
    [Abstract] [Full Text] [Related]

  • 9. DGT measurement of dissolved aluminum species in waters: comparing Chelex-100 and titanium dioxide-based adsorbents.
    Panther JG, Bennett WW, Teasdale PR, Welsh DT, Zhao H.
    Environ Sci Technol; 2012 Feb 21; 46(4):2267-75. PubMed ID: 22268706
    [Abstract] [Full Text] [Related]

  • 10. Titanium dioxide-based DGT for measuring dissolved As(V), V(V), Sb(V), Mo(VI) and W(VI) in water.
    Panther JG, Stewart RR, Teasdale PR, Bennett WW, Welsh DT, Zhao H.
    Talanta; 2013 Feb 15; 105():80-6. PubMed ID: 23597992
    [Abstract] [Full Text] [Related]

  • 11. Speciation analysis of inorganic arsenic in river water by Amberlite IRA 910 resin immobilized in a polyacrylamide gel as a selective binding agent for As(V) in diffusive gradient thin film technique.
    Rolisola AM, Suárez CA, Menegário AA, Gastmans D, Kiang CH, Colaço CD, Garcez DL, Santelli RE.
    Analyst; 2014 Sep 07; 139(17):4373-80. PubMed ID: 25010156
    [Abstract] [Full Text] [Related]

  • 12. A novel passive water sampler for in situ sampling of antibiotics.
    Chen CE, Zhang H, Jones KC.
    J Environ Monit; 2012 May 07; 14(6):1523-30. PubMed ID: 22538362
    [Abstract] [Full Text] [Related]

  • 13.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 14. Determination of mercury in river water by diffusive gradients in thin films using P81 membrane as binding layer.
    Colaço CD, Yabuki LN, Rolisola AM, Menegário AA, de Almeida E, Suárez CA, Gao Y, Corns WT, do Nascimento Filho VF.
    Talanta; 2014 Nov 07; 129():417-21. PubMed ID: 25127614
    [Abstract] [Full Text] [Related]

  • 15. Evaluation of the DGT technique for selective measurement of aluminium and trace metal concentrations in an acid drainage-impacted coastal waterway.
    Shiva AH, Teasdale PR, Welsh DT, Bennett WW.
    Environ Sci Process Impacts; 2017 May 24; 19(5):742-751. PubMed ID: 28426038
    [Abstract] [Full Text] [Related]

  • 16.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 17. Novel in situ method based on diffusive gradients in thin-films with lanthanum oxide nanoparticles for measuring As, Sb, and V and in waters.
    Li K, Liu Z, Shi X, Wei TJ, Ma LQ, Luo J.
    J Hazard Mater; 2020 Feb 05; 383():121196. PubMed ID: 31539663
    [Abstract] [Full Text] [Related]

  • 18. Evaluation of the diffusive gradients in thin films technique using a mixed binding gel for measuring iron, phosphorus and arsenic in the environment.
    Sun Q, Zhang L, Ding S, Li C, Yang J, Chen J, Wang P.
    Environ Sci Process Impacts; 2015 Mar 05; 17(3):570-7. PubMed ID: 25599812
    [Abstract] [Full Text] [Related]

  • 19. Trace metal measurements in low ionic strength synthetic solutions by diffusive gradients in thin films.
    Warnken KW, Zhang H, Davison W.
    Anal Chem; 2005 Sep 01; 77(17):5440-6. PubMed ID: 16131050
    [Abstract] [Full Text] [Related]

  • 20. Key role of the sorption process in alteration of metal and metalloid quantification by fouling development on DGT passive samplers.
    Devillers D, Buzier R, Grybos M, Charriau A, Guibaud G.
    Environ Pollut; 2017 Nov 01; 230():523-529. PubMed ID: 28704749
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 11.