These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


303 related items for PubMed ID: 28822314

  • 1. A portable smart-phone device for rapid and sensitive detection of E. coli O157:H7 in Yoghurt and Egg.
    Zeinhom MMA, Wang Y, Song Y, Zhu MJ, Lin Y, Du D.
    Biosens Bioelectron; 2018 Jan 15; 99():479-485. PubMed ID: 28822314
    [Abstract] [Full Text] [Related]

  • 2.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 3. Simple sensitive rapid detection of Escherichia coli O157:H7 in food samples by label-free immunofluorescence strip sensor.
    Song C, Li J, Liu J, Liu Q.
    Talanta; 2016 Aug 15; 156-157():42-47. PubMed ID: 27260433
    [Abstract] [Full Text] [Related]

  • 4. A novel fluorescence immunoassay for the sensitive detection of Escherichia coli O157:H7 in milk based on catalase-mediated fluorescence quenching of CdTe quantum dots.
    Chen R, Huang X, Li J, Shan S, Lai W, Xiong Y.
    Anal Chim Acta; 2016 Dec 01; 947():50-57. PubMed ID: 27846989
    [Abstract] [Full Text] [Related]

  • 5. An integrated magnetic separation enzyme-linked colorimetric sensing platform for field detection of Escherichia coli O157: H7 in food.
    Wang C, Deng R, Li H, Liu Z, Niu X, Li X.
    Mikrochim Acta; 2024 Jul 08; 191(8):454. PubMed ID: 38976069
    [Abstract] [Full Text] [Related]

  • 6. A microfluidic colorimetric biosensor for rapid detection of Escherichia coli O157:H7 using gold nanoparticle aggregation and smart phone imaging.
    Zheng L, Cai G, Wang S, Liao M, Li Y, Lin J.
    Biosens Bioelectron; 2019 Jan 15; 124-125():143-149. PubMed ID: 30366259
    [Abstract] [Full Text] [Related]

  • 7. A novel biosensor for Escherichia coli O157:H7 based on fluorescein-releasable biolabels.
    Hu RR, Yin ZZ, Zeng YB, Zhang J, Liu HQ, Shao Y, Ren SB, Li L.
    Biosens Bioelectron; 2016 Apr 15; 78():31-36. PubMed ID: 26584080
    [Abstract] [Full Text] [Related]

  • 8. Sensitive chemiluminescence immunoassay for E. coli O157:H7 detection with signal dual-amplification using glucose oxidase and laccase.
    Zhang Y, Tan C, Fei R, Liu X, Zhou Y, Chen J, Chen H, Zhou R, Hu Y.
    Anal Chem; 2014 Jan 21; 86(2):1115-22. PubMed ID: 24405233
    [Abstract] [Full Text] [Related]

  • 9. DNA-based hybridization chain reaction and biotin-streptavidin signal amplification for sensitive detection of Escherichia coli O157:H7 through ELISA.
    Guo Q, Han JJ, Shan S, Liu DF, Wu SS, Xiong YH, Lai WH.
    Biosens Bioelectron; 2016 Dec 15; 86():990-995. PubMed ID: 27498326
    [Abstract] [Full Text] [Related]

  • 10. Rapid and selective detection of E. coli O157:H7 combining phagomagnetic separation with enzymatic colorimetry.
    Zhang Y, Yan C, Yang H, Yu J, Wei H.
    Food Chem; 2017 Nov 01; 234():332-338. PubMed ID: 28551244
    [Abstract] [Full Text] [Related]

  • 11.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 12. Fluorescent biosensor based on magnetic separation platform and spore-like breakable organosilica nanocapsules controlled-release carbon dots for the detection of Escherichia coli O157:H7.
    Ling Z, Xu Q, Song Y, Zhang W, Xu H.
    Talanta; 2024 Aug 15; 276():126273. PubMed ID: 38776775
    [Abstract] [Full Text] [Related]

  • 13. A novel smartphone-based colorimetric aptasensor for on-site detection of Escherichia coli O157:H7 in milk.
    Yang T, Wang Z, Song Y, Yang X, Chen S, Fu S, Qin X, Zhang W, Man C, Jiang Y.
    J Dairy Sci; 2021 Aug 15; 104(8):8506-8516. PubMed ID: 34053767
    [Abstract] [Full Text] [Related]

  • 14. Detection of Escherichia coli O157:H7 using chicken immunoglobulin Y.
    Sunwoo HH, Wang WW, Sim JS.
    Immunol Lett; 2006 Aug 15; 106(2):191-3. PubMed ID: 16781781
    [Abstract] [Full Text] [Related]

  • 15. Monitoring of Escherichia coli O157:H7 in food samples using lectin based surface plasmon resonance biosensor.
    Wang Y, Ye Z, Si C, Ying Y.
    Food Chem; 2013 Feb 15; 136(3-4):1303-8. PubMed ID: 23194527
    [Abstract] [Full Text] [Related]

  • 16. Graphene-interfaced electrical biosensor for label-free and sensitive detection of foodborne pathogenic E. coli O157:H7.
    Pandey A, Gurbuz Y, Ozguz V, Niazi JH, Qureshi A.
    Biosens Bioelectron; 2017 May 15; 91():225-231. PubMed ID: 28012318
    [Abstract] [Full Text] [Related]

  • 17. Detection and isolation of low levels of E. coli O157:H7 in cilantro by real-time PCR, immunomagnetic separation, and cultural methods with and without an acid treatment.
    Yoshitomi KJ, Jinneman KC, Zapata R, Weagant SD, Fedio WM.
    J Food Sci; 2012 Aug 15; 77(8):M481-9. PubMed ID: 22860597
    [Abstract] [Full Text] [Related]

  • 18. The Development of a Portable SPR Bioanalyzer for Sensitive Detection of Escherichia coli O157:H7.
    Wang S, Xie J, Jiang M, Chang K, Chen R, Ma L, Zhu J, Guo Q, Sun H, Hu J.
    Sensors (Basel); 2016 Nov 04; 16(11):. PubMed ID: 27827923
    [Abstract] [Full Text] [Related]

  • 19.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 20. Phage-induced "one-to-many" FRET sensor for highly sensitive detection of Escherichia coli O157:H7.
    Meng M, Ma X, Yu L, Zhang X, Chen Y, Li W, Wen Q, Xu D, Chen Q, Xiong Y, Ren J.
    Biosens Bioelectron; 2024 Nov 15; 264():116661. PubMed ID: 39142229
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 16.