3. Production of compound A and carbon monoxide in circle systems: an in vitro comparison of two carbon dioxide absorbents. Struys MM, Bouche MP, Rolly G, Vandevivere YD, Dyzers D, Goeteyn W, Versichelen LF, Van Bocxlaer JF, Mortier EP. Anaesthesia; 2004 Jun; 59(6):584-9. PubMed ID: 15144299 [Abstract] [Full Text] [Related]
4. Amsorb: a new carbon dioxide absorbent for use in anesthetic breathing systems. Murray JM, Renfrew CW, Bedi A, McCrystal CB, Jones DS, Fee JP. Anesthesiology; 1999 Nov; 91(5):1342-8. PubMed ID: 10551585 [Abstract] [Full Text] [Related]
5. High carboxyhemoglobin concentrations occur in swine during desflurane anesthesia in the presence of partially dried carbon dioxide absorbents. Frink EJ, Nogami WM, Morgan SE, Salmon RC. Anesthesiology; 1997 Aug; 87(2):308-16. PubMed ID: 9286895 [Abstract] [Full Text] [Related]
9. Small carbon monoxide formation in absorbents does not correlate with small carbon dioxide absorption. Knolle E, Heinze G, Gilly H. Anesth Analg; 2002 Sep; 95(3):650-5, table of contents. PubMed ID: 12198054 [Abstract] [Full Text] [Related]
10. Physical factors affecting the production of carbon monoxide from anesthetic breakdown. Woehlck HJ, Dunning M, Raza T, Ruiz F, Bolla B, Zink W. Anesthesiology; 2001 Mar; 94(3):453-6. PubMed ID: 11374605 [Abstract] [Full Text] [Related]
11. Carbon monoxide production from desflurane and six types of carbon dioxide absorbents in a patient model. Keijzer C, Perez RS, de Lange JJ. Acta Anaesthesiol Scand; 2005 Jul; 49(6):815-8. PubMed ID: 15954965 [Abstract] [Full Text] [Related]
12. An evaluation of the contributions by fresh gas flow rate, carbon dioxide concentration and desflurane partial pressure to carbon monoxide concentration during low fresh gas flows to a circle anaesthetic breathing system. Fan SZ, Lin YW, Chang WS, Tang CS. Eur J Anaesthesiol; 2008 Aug; 25(8):620-6. PubMed ID: 18339215 [Abstract] [Full Text] [Related]
13. Interaction of inhalational anaesthetics with CO2 absorbents. Baum JA, Woehlck HJ. Best Pract Res Clin Anaesthesiol; 2003 Mar; 17(1):63-76. PubMed ID: 12751549 [Abstract] [Full Text] [Related]
14. Lack of degradation of sevoflurane by a new carbon dioxide absorbent in humans. Mchaourab A, Arain SR, Ebert TJ. Anesthesiology; 2001 Jun; 94(6):1007-9. PubMed ID: 11465591 [Abstract] [Full Text] [Related]