These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
1144 related items for PubMed ID: 28836973
21. A newly designed locked intramedullary nail for trochanteric hip fractures fixation: results of the first 100 Trochanteric implantations. Loubignac F, Chabas JF. Orthop Traumatol Surg Res; 2009 Apr; 95(2):139-44. PubMed ID: 19345659 [Abstract] [Full Text] [Related]
22. The trochanteric nail versus the sliding hip screw for intertrochanteric hip fractures: a review of 93 cases. Crawford CH, Malkani AL, Cordray S, Roberts CS, Sligar W. J Trauma; 2006 Feb; 60(2):325-8; discussion 328-9. PubMed ID: 16508490 [Abstract] [Full Text] [Related]
23. Proximal femoral fractures: a biomechanical study to compare intramedullary and extramedullary fixation. Curtis MJ, Jinnah RH, Wilson V, Cunningham BW. Injury; 1994 Mar; 25(2):99-104. PubMed ID: 8138307 [Abstract] [Full Text] [Related]
24. Extramedullary fixation implants and external fixators for extracapsular hip fractures in adults. Parker MJ, Das A. Cochrane Database Syst Rev; 2013 Feb 28; 2013(2):CD000339. PubMed ID: 23450528 [Abstract] [Full Text] [Related]
25. Sliding hip screw versus IM nail in reverse oblique trochanteric and subtrochanteric fractures. A study of 2716 patients in the Norwegian Hip Fracture Register. Matre K, Havelin LI, Gjertsen JE, Vinje T, Espehaug B, Fevang JM. Injury; 2013 Jun 28; 44(6):735-42. PubMed ID: 23305689 [Abstract] [Full Text] [Related]
26. Causes and treatments of lag screw's cut out after intramedullary nailing osteosinthesis for trochanteric fractures. Gazzotti G, Matino G, Tsatsis C, Sacchetti G, Baudi P, Catani F. Acta Biomed; 2014 Aug 20; 85(2):135-43. PubMed ID: 25245649 [Abstract] [Full Text] [Related]
30. [Therapeutic possibilities in trochanteric fractures. Safe--fast--stable]. Dávid A, von der Heyde D, Pommer A. Orthopade; 2000 Apr 25; 29(4):294-301. PubMed ID: 10851690 [Abstract] [Full Text] [Related]
31. Biaxial dynamization in unstable intertrochanteric fractures. Good experience with a simplified Medoff sliding plate in 94 patients. Olsson O, Ceder L, Lunsjö K, Hauggaard A. Acta Orthop Scand; 1997 Aug 25; 68(4):327-31. PubMed ID: 9310034 [Abstract] [Full Text] [Related]
32. Extramedullary fixation of 569 unstable intertrochanteric fractures: a randomized multicenter trial of the Medoff sliding plate versus three other screw-plate systems. Lunsjö K, Ceder L, Thorngren KG, Skytting B, Tidermark J, Berntson PO, Allvin I, Norberg S, Hjalmars K, Larsson S, Knebel R, Hauggaard A, Stigsson L. Acta Orthop Scand; 2001 Apr 25; 72(2):133-40. PubMed ID: 11372943 [Abstract] [Full Text] [Related]
37. Gamma 3 U-Blade lag screws in patients with trochanteric femur fractures: are rotation control lag screws better than others? Yoo J, Kim S, Choi J, Hwang J. J Orthop Surg Res; 2019 Dec 16; 14(1):440. PubMed ID: 31842911 [Abstract] [Full Text] [Related]
38. Use of an intramedullary hip-screw compared with a compression hip-screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundred patients. Hardy DC, Descamps PY, Krallis P, Fabeck L, Smets P, Bertens CL, Delince PE. J Bone Joint Surg Am; 1998 May 16; 80(5):618-30. PubMed ID: 9611022 [Abstract] [Full Text] [Related]