These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


291 related items for PubMed ID: 28965299

  • 1. Value of bioimpedance analysis estimated "dry weight" in maintenance dialysis patients: a systematic review and meta-analysis.
    Covic A, Ciumanghel AI, Siriopol D, Kanbay M, Dumea R, Gavrilovici C, Nistor I.
    Int Urol Nephrol; 2017 Dec; 49(12):2231-2245. PubMed ID: 28965299
    [Abstract] [Full Text] [Related]

  • 2. Bioimpedance-guided fluid management in maintenance hemodialysis: a pilot randomized controlled trial.
    Onofriescu M, Hogas S, Voroneanu L, Apetrii M, Nistor I, Kanbay M, Covic AC.
    Am J Kidney Dis; 2014 Jul; 64(1):111-8. PubMed ID: 24583055
    [Abstract] [Full Text] [Related]

  • 3. Randomized trial of bioelectrical impedance analysis versus clinical criteria for guiding ultrafiltration in hemodialysis patients: effects on blood pressure, hydration status, and arterial stiffness.
    Onofriescu M, Mardare NG, Segall L, Voroneanu L, Cuşai C, Hogaş S, Ardeleanu S, Nistor I, Prisadă OV, Sascău R, Covic A.
    Int Urol Nephrol; 2012 Apr; 44(2):583-91. PubMed ID: 21688195
    [Abstract] [Full Text] [Related]

  • 4. Clinical usefulness of bioimpedance analysis for assessing volume status in patients receiving maintenance dialysis.
    Park JH, Jo YI, Lee JH.
    Korean J Intern Med; 2018 Jul; 33(4):660-669. PubMed ID: 29961308
    [Abstract] [Full Text] [Related]

  • 5. Bioimpedance Guided Fluid Management in Peritoneal Dialysis: A Randomized Controlled Trial.
    Tian N, Yang X, Guo Q, Zhou Q, Yi C, Lin J, Cao P, Ye H, Chen M, Yu X.
    Clin J Am Soc Nephrol; 2020 May 07; 15(5):685-694. PubMed ID: 32349977
    [Abstract] [Full Text] [Related]

  • 6. Practical aspects of volume control in chronic kidney disease using whole body bioimpedance.
    Oei EL, Fan SL.
    Blood Purif; 2015 May 07; 39(1-3):32-6. PubMed ID: 25660496
    [Abstract] [Full Text] [Related]

  • 7. Relations between malnutrition-inflammation-atherosclerosis and volume status. The usefulness of bioimpedance analysis in peritoneal dialysis patients.
    Demirci MS, Demirci C, Ozdogan O, Kircelli F, Akcicek F, Basci A, Ok E, Ozkahya M.
    Nephrol Dial Transplant; 2011 May 07; 26(5):1708-16. PubMed ID: 20921295
    [Abstract] [Full Text] [Related]

  • 8. The Relationship of Fluid Overload as Assessed by Bioelectrical Impedance Analysis with Pulmonary Arterial Hypertension in Hemodialysis Patients.
    Yılmaz S, Yildirim Y, Taylan M, Demir M, Yilmaz Z, Kara AV, Aydin F, Sen HS, Karabulut A, Topcu F.
    Med Sci Monit; 2016 Feb 14; 22():488-94. PubMed ID: 26874785
    [Abstract] [Full Text] [Related]

  • 9. The effect of hemodialysis on the body composition and cardiovascular disease markers in recently diagnosed end stage renal disease patients.
    Cakiroglu U, Akdam H, Eryilmaz U, Akgullu C, Ozbek O, Büyüköztürk AK, Akar H, Yenicerioglu Y.
    Rev Assoc Med Bras (1992); 2018 Apr 14; 64(4):354-360. PubMed ID: 30133615
    [Abstract] [Full Text] [Related]

  • 10. Reliability of blood pressure parameters for dry weight estimation in hemodialysis patients.
    Susantitaphong P, Laowaloet S, Tiranathanagul K, Chulakadabba A, Katavetin P, Praditpornsilpa K, Tungsanga K, Eiam-Ong S.
    Ther Apher Dial; 2013 Feb 14; 17(1):9-15. PubMed ID: 23379487
    [Abstract] [Full Text] [Related]

  • 11. Association Between Home Blood Pressure and Body Composition by Bioimpedance Monitoring in Patients Undergoing Peritoneal Dialysis.
    Kurasawa N, Mori T, Naganuma E, Sato E, Koizumi K, Sato S, Oba I, Tsuchikawa M, Ito S.
    Adv Perit Dial; 2015 Feb 14; 31():38-44. PubMed ID: 26714387
    [Abstract] [Full Text] [Related]

  • 12. Effect of bioelectrical impedance analysis-guided dry weight adjustment, in comparison to standard clinical-guided, on the sleep quality of chronic haemodialysis patients (BEDTIME study): a randomised controlled trial.
    Sethakarun S, Bijaphala S, Kitiyakara C, Boongird S, Phanachet P, Reutrakul S, Pirojsakul K, Nongnuch A.
    BMC Nephrol; 2019 Sep 02; 20(1):211. PubMed ID: 31474223
    [Abstract] [Full Text] [Related]

  • 13. Assessment of Hydration Status in Peritoneal Dialysis Patients: Validity, Prognostic Value, Strengths, and Limitations of Available Techniques.
    Alexandrou ME, Balafa O, Sarafidis P.
    Am J Nephrol; 2020 Sep 02; 51(8):589-612. PubMed ID: 32721969
    [Abstract] [Full Text] [Related]

  • 14. Independent Association of Overhydration with All-Cause and Cardiovascular Mortality Adjusted for Global Left Ventricular Longitudinal Systolic Strain and E/E' Ratio in Maintenance Hemodialysis Patients.
    Huang JC, Tsai YC, Wu PY, Lee JJ, Chen SC, Chiu YW, Hsu YL, Chang JM, Chen HC.
    Kidney Blood Press Res; 2018 Sep 02; 43(4):1322-1332. PubMed ID: 30099445
    [Abstract] [Full Text] [Related]

  • 15. Bioimpedance, dry weight and blood pressure control: new methods and consequences.
    Kuhlmann MK, Zhu F, Seibert E, Levin NW.
    Curr Opin Nephrol Hypertens; 2005 Nov 02; 14(6):543-9. PubMed ID: 16205473
    [Abstract] [Full Text] [Related]

  • 16. Pulmonary Hypertension, Mortality, and Cardiovascular Disease in CKD and ESRD Patients: A Systematic Review and Meta-analysis.
    Tang M, Batty JA, Lin C, Fan X, Chan KE, Kalim S.
    Am J Kidney Dis; 2018 Jul 02; 72(1):75-83. PubMed ID: 29429751
    [Abstract] [Full Text] [Related]

  • 17. Evaluation of fluid status related parameters in hemodialysis and peritoneal dialysis patients: Clinical usefulness of bioimpedance analysis.
    Yılmaz Z, Yıldırım Y, Aydın FY, Aydın E, Kadiroğlu AK, Yılmaz ME, Acet H.
    Medicina (Kaunas); 2014 Jul 02; 50(5):269-74. PubMed ID: 25488162
    [Abstract] [Full Text] [Related]

  • 18. The promise of bioimpedance for volume management in American dialysis patients: An unfulfilled opportunity.
    Kotanko P.
    Semin Dial; 2019 May 02; 32(3):223-224. PubMed ID: 30927285
    [Abstract] [Full Text] [Related]

  • 19. Effect of fluid management guided by bioimpedance spectroscopy on cardiovascular parameters in hemodialysis patients: a randomized controlled trial.
    Hur E, Usta M, Toz H, Asci G, Wabel P, Kahvecioglu S, Kayikcioglu M, Demirci MS, Ozkahya M, Duman S, Ok E.
    Am J Kidney Dis; 2013 Jun 02; 61(6):957-65. PubMed ID: 23415416
    [Abstract] [Full Text] [Related]

  • 20. Bioelectric impedance predicts total body water, blood pressure, and heart rate during hemodialysis in children and adolescents.
    Brooks ER, Fatallah-Shaykh SA, Langman CB, Wolf KM, Price HE.
    J Ren Nutr; 2008 May 02; 18(3):304-11. PubMed ID: 18410888
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 15.