These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
261 related items for PubMed ID: 29124384
21. Usefulness of 64-detector row computed tomography for evaluation of intracoronary stents in symptomatic patients with suspected in-stent restenosis. Manghat N, Van Lingen R, Hewson P, Syed F, Kakani N, Cox I, Roobottom C, Morgan-Hughes G. Am J Cardiol; 2008 Jun 01; 101(11):1567-73. PubMed ID: 18489934 [Abstract] [Full Text] [Related]
22. Multislice spiral computed tomography for the evaluation of stent patency after left main coronary artery stenting: a comparison with conventional coronary angiography and intravascular ultrasound. Van Mieghem CA, Cademartiri F, Mollet NR, Malagutti P, Valgimigli M, Meijboom WB, Pugliese F, McFadden EP, Ligthart J, Runza G, Bruining N, Smits PC, Regar E, van der Giessen WJ, Sianos G, van Domburg R, de Jaegere P, Krestin GP, Serruys PW, de Feyter PJ. Circulation; 2006 Aug 15; 114(7):645-53. PubMed ID: 16894038 [Abstract] [Full Text] [Related]
23. Multidetector computed tomography angiography for assessment of in-stent restenosis: meta-analysis of diagnostic performance. Vanhoenacker PK, Decramer I, Bladt O, Sarno G, Van Hul E, Wijns W, Dwamena BA. BMC Med Imaging; 2008 Jul 31; 8():14. PubMed ID: 18671850 [Abstract] [Full Text] [Related]
24. Rationale and design of advantage (additional diagnostic value of CT perfusion over coronary CT angiography in stented patients with suspected in-stent restenosis or coronary artery disease progression) prospective study. Andreini D, Mushtaq S, Pontone G, Conte E, Sonck J, Collet C, Guglielmo M, Baggiano A, Trabattoni D, Galli S, Montorsi P, Ferrari C, Fabbiocchi F, De Martini S, Annoni A, Mancini ME, Formenti A, Magatelli M, Resta M, Consiglio E, Muscogiuri G, Fiorentini C, Bartorelli AL, Pepi M. J Cardiovasc Comput Tomogr; 2018 Jul 31; 12(5):411-417. PubMed ID: 29933938 [Abstract] [Full Text] [Related]
25. Prediction value of pericoronary fat attenuation index for coronary in-stent restenosis. Lu ZF, Yin WH, Schoepf UJ, Abrol S, Ma JW, Zhao L, Su XM, An YQ, Xiao ZC, Lu B. Eur Radiol; 2024 Aug 31; 34(8):4950-4959. PubMed ID: 38224375 [Abstract] [Full Text] [Related]
26. Predictors for functionally significant in-stent restenosis: an integrated analysis using coronary angiography, IVUS, and myocardial perfusion imaging. Kang SJ, Cho YR, Park GM, Ahn JM, Han SB, Lee JY, Kim WJ, Park DW, Lee SW, Kim YH, Lee CW, Park SW, Mintz GS, Park SJ. JACC Cardiovasc Imaging; 2013 Nov 31; 6(11):1183-90. PubMed ID: 24229771 [Abstract] [Full Text] [Related]
27. Non-invasive evaluation of coronary artery stent patency with retrospectively ECG-gated 64-slice CT angiography. Carbone I, Francone M, Algeri E, Granatelli A, Napoli A, Kirchin MA, Catalano C, Passariello R. Eur Radiol; 2008 Feb 31; 18(2):234-43. PubMed ID: 17929024 [Abstract] [Full Text] [Related]
28. Diagnostic accuracy of coronary CT angiography performed in 100 consecutive patients with coronary stents using a whole-organ high-definition CT scanner. Andreini D, Pontone G, Mushtaq S, Conte E, Guglielmo M, Mancini ME, Annoni A, Baggiano A, Formenti A, Montorsi P, Magatelli M, Di Odoardo L, Melotti E, Resta M, Muscogiuri G, Fiorentini C, Bartorelli AL, Pepi M. Int J Cardiol; 2019 Jan 01; 274():382-387. PubMed ID: 30219253 [Abstract] [Full Text] [Related]
29. Incidence and classification of neointimal proliferation and in-stent restenosis in post-stenting patients at 1-year interval: findings from non-invasive coronary computed tomography angiography. Xu N, Zhang J, Li M, Pan J, Lu Z. Eur J Radiol; 2014 Oct 01; 83(10):1816-21. PubMed ID: 25112673 [Abstract] [Full Text] [Related]
30. CT Angiography for the Detection of Coronary Artery Stenoses in Patients Referred for Cardiac Valve Surgery: Systematic Review and Meta-Analysis. Opolski MP, Staruch AD, Jakubczyk M, Min JK, Gransar H, Staruch M, Witkowski A, Kepka C, Kim WK, Hamm CW, Möllmann H, Achenbach S. JACC Cardiovasc Imaging; 2016 Sep 01; 9(9):1059-1070. PubMed ID: 27344418 [Abstract] [Full Text] [Related]
31. Diagnostic accuracy of in-stent restenosis using model-based iterative reconstruction at coronary CT angiography: initial experience. Tatsugami F, Higaki T, Sakane H, Nakamura Y, Iida M, Baba Y, Fujioka C, Senoo A, Kitagawa T, Yamamoto H, Kihara Y, Awai K. Br J Radiol; 2018 Feb 01; 91(1082):20170598. PubMed ID: 29022741 [Abstract] [Full Text] [Related]
32. Contrast-enhanced 64-section coronary multidetector CT angiography versus conventional coronary angiography for stent assessment. Das KM, El-Menyar AA, Salam AM, Singh R, Dabdoob WA, Albinali HA, Al Suwaidi J. Radiology; 2007 Nov 01; 245(2):424-32. PubMed ID: 17890354 [Abstract] [Full Text] [Related]
34. Diagnostic Accuracy of Coronary CT Angiography for the Evaluation of Bioresorbable Vascular Scaffolds. Collet C, Chevalier B, Cequier A, Fajadet J, Dominici M, Helqvist S, Van Boven AJ, Dudek D, McClean D, Almeida M, Piek JJ, Tenekecioglu E, Bartorelli A, Windecker S, Serruys PW, Onuma Y. JACC Cardiovasc Imaging; 2018 May 01; 11(5):722-732. PubMed ID: 28734923 [Abstract] [Full Text] [Related]
35. Cost-effectiveness of stress CTP versus CTA in detecting obstructive CAD or in-stent restenosis in stented patients. Kim SH, Rübenthaler J, Nörenberg D, Huber T, Kunz WG, Sommer WH, Schoenberg SO, Janssen S, Overhoff D, Froelich MF. Eur Radiol; 2021 Mar 01; 31(3):1443-1450. PubMed ID: 32885295 [Abstract] [Full Text] [Related]
36. Spectral Photon-Counting Computed Tomography for Coronary Stent Imaging: Evaluation of the Potential Clinical Impact for the Delineation of In-Stent Restenosis. Bratke G, Hickethier T, Bar-Ness D, Bunck AC, Maintz D, Pahn G, Coulon P, Si-Mohamed S, Douek P, Sigovan M. Invest Radiol; 2020 Feb 01; 55(2):61-67. PubMed ID: 31524765 [Abstract] [Full Text] [Related]
37. The usefulness of subtraction coronary computed tomography angiography for in-stent restenosis assessment of patients with CoCr stent using 320-row area detector CT. Li J, Guo MT, Yang X, Gao F, Li N, Huang MG. Medicine (Baltimore); 2021 Dec 23; 100(51):e28345. PubMed ID: 34941141 [Abstract] [Full Text] [Related]