These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


83 related items for PubMed ID: 2922723

  • 1. [Correct handling of serum separating gel tubes is of significance].
    Daae LN, Juell A, Lund PK.
    Tidsskr Nor Laegeforen; 1989 Feb 20; 109(5):599-601. PubMed ID: 2922723
    [Abstract] [Full Text] [Related]

  • 2. Reliability of serum separator blood drawing tubes under routine conditions.
    Eichhorn U, Helwig-Rolig A, Kirchner G, Kropf J, Gressner AM.
    Eur J Clin Chem Clin Biochem; 1997 Jun 20; 35(6):483-4. PubMed ID: 9228333
    [No Abstract] [Full Text] [Related]

  • 3. [Use of heparinized tubes for collection of blood intended for chemical analysis, especially for potassium determination].
    Michod J, Platsoukas C, Frei J.
    Z Klin Chem Klin Biochem; 1970 Sep 08; 7(5):455-7. PubMed ID: 5505954
    [No Abstract] [Full Text] [Related]

  • 4. Solution densities and estimated total protein contents associated with inappropriate flotation of separator gel in different blood collection tubes.
    Faught RC, Marshall J, Bornhorst J.
    Arch Pathol Lab Med; 2011 Sep 08; 135(9):1081-4. PubMed ID: 21877989
    [Abstract] [Full Text] [Related]

  • 5. Measurement of organochlorine levels in postprandial serum or in blood collected in serum separator tubes.
    Longnecker MP, Bernstein L, Bird CL, Yancey AK, Peterson JC.
    Cancer Epidemiol Biomarkers Prev; 1996 Sep 08; 5(9):753-5. PubMed ID: 8877068
    [Abstract] [Full Text] [Related]

  • 6. [Errors in the serum potassium titer due to the sampling technic].
    Papadimitriou GC, Lappas CA.
    Gynecol Obstet (Paris); 1967 Sep 08; 66(2):223-8. PubMed ID: 6059816
    [No Abstract] [Full Text] [Related]

  • 7. Absorption of therapeutic drugs by barrier gels in serum separator blood collection tubes. Volume- and time-dependent reduction in total and free drug concentrations.
    Dasgupta A, Dean R, Saldana S, Kinnaman G, McLawhon RW.
    Am J Clin Pathol; 1994 Apr 08; 101(4):456-61. PubMed ID: 8160636
    [Abstract] [Full Text] [Related]

  • 8. Elevated results in a vitamin B12 assay when using serum separator blood collection tubes.
    Lowrey I, Smith G.
    Ann Clin Biochem; 2003 Sep 08; 40(Pt 5):560-2. PubMed ID: 14503995
    [Abstract] [Full Text] [Related]

  • 9. The effect of recentrifugation of serum separator tubes on concentration of serum analytes.
    Shafi H, Sadrzadeh H.
    Ann Clin Lab Sci; 2012 Sep 08; 42(3):318-9. PubMed ID: 22964622
    [Abstract] [Full Text] [Related]

  • 10. Influence of separator gel in Sarstedt S-Monovette® serum tubes on various therapeutic drugs, hormones, and proteins.
    Schouwers S, Brandt I, Willemse J, Van Regenmortel N, Uyttenbroeck W, Wauters A, Neels H.
    Clin Chim Acta; 2012 Jan 18; 413(1-2):100-4. PubMed ID: 21945632
    [Abstract] [Full Text] [Related]

  • 11. Use of gel-based separator tubes to stabilise phosphate in mailed blood samples.
    Herrington W, Clark S, Staplin N, Kumar A, Illingworth N, Sutherland S, Baigent C, Landray M, Haynes R, Hill M.
    Clin Chim Acta; 2015 Jan 15; 439():112-4. PubMed ID: 25280640
    [No Abstract] [Full Text] [Related]

  • 12. Increase in Serum Potassium Levels After Refrigerated Storage: A Component of Blood Clot Contaminates the Serum Layer Over the Separator Gel.
    Yoshida K, Tani H, Nobuhara S, Yamamoto S.
    Biopreserv Biobank; 2024 Jun 15; 22(3):235-241. PubMed ID: 37943629
    [Abstract] [Full Text] [Related]

  • 13. Differences between values for plasma and serum in tests performed in the Ektachem 700 XR Analyzer, and evaluation of "plasma separator tubes (PST)".
    Doumas BT, Hause LL, Simuncak DM, Breitenfeld D.
    Clin Chem; 1989 Jan 15; 35(1):151-3. PubMed ID: 2910557
    [Abstract] [Full Text] [Related]

  • 14. Evaluation of BD Vacutainer SST™ II Plus tubes for common tumor marker tests by Roche Diagnostics Modular E 170 analyzer.
    Li Z, Feng Z, Yan C, Yan R.
    J Clin Lab Anal; 2010 Jan 15; 24(6):418-21. PubMed ID: 21089174
    [Abstract] [Full Text] [Related]

  • 15. Reduced serum tricyclic levels due to gel separators.
    Levy AB, Walters M, Stern SL.
    J Clin Psychopharmacol; 1987 Dec 15; 7(6):423-4. PubMed ID: 3429705
    [Abstract] [Full Text] [Related]

  • 16. Blood collection by evacuated tubes: the effects of the order of filling tubes on the serum values of potassium and lactate dehydrogenase.
    Alegre B, Miralles A, Martinez C, Otte A, Calero G.
    Ann Biol Clin (Paris); 1989 Dec 15; 47(8):507. PubMed ID: 2604062
    [No Abstract] [Full Text] [Related]

  • 17. Where clinical chemistry meets medicinal chemistry. Systematic analysis of physico-chemical properties predicts stability of common used drugs in gel separator serum tubes.
    Steuer C, Huber AR, Bernasconi L.
    Clin Chim Acta; 2016 Nov 01; 462():23-27. PubMed ID: 27567701
    [Abstract] [Full Text] [Related]

  • 18. Comparison of plastic vs. glass evacuated serum-separator (SST) blood-drawing tubes for common clinical chemistry determinations.
    Hill BM, Laessig RH, Koch DD, Hassemer DJ.
    Clin Chem; 1992 Aug 01; 38(8 Pt 1):1474-8. PubMed ID: 1643717
    [Abstract] [Full Text] [Related]

  • 19. Evaluation of serum separator tubes as a mail transport device in primary health care.
    Sandberg S, Christensen NG, Horgen E, Jacobsen H, Johansen K.
    Scand J Prim Health Care; 1988 Nov 01; 6(4):251-4. PubMed ID: 3231943
    [Abstract] [Full Text] [Related]

  • 20. Effects of sample handling on total carbon dioxide concentrations in canine and feline serum and blood.
    James KM, Polzin DJ, Osborne CA, Olson JK.
    Am J Vet Res; 1997 Apr 01; 58(4):343-7. PubMed ID: 9099375
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 5.