21. Comparison of the accuracy of noninvasive hemoglobin sensor (NBM-200) and portable hemoglobinometer (HemoCue) with an automated hematology analyzer (LH500) in blood donor screening. Kim MJ, Park Q, Kim MH, Shin JW, Kim HO. Ann Lab Med; 2013 Jul; 33(4):261-7. PubMed ID: 23826562 [Abstract] [Full Text] [Related]
22. Systematic review and meta-analysis of method comparison studies of Masimo pulse co-oximeters (Radical-7™ or Pronto-7™) and HemoCue® absorption spectrometers (B-Hemoglobin or 201+) with laboratory haemoglobin estimation. Hiscock R, Kumar D, Simmons SW. Anaesth Intensive Care; 2015 May; 43(3):341-50. PubMed ID: 25943608 [Abstract] [Full Text] [Related]
23. Validation of hemoglobin estimation using Hemocue. Bhaskaram P, Balakrishna N, Radhakrishna KV, Krishnaswamy K. Indian J Pediatr; 2003 Jan; 70(1):25-8. PubMed ID: 12619948 [Abstract] [Full Text] [Related]
24. Point-of-Care Testing Using Invasive and Non-Invasive Hemoglobinometers: Reliable and Valid Method for Estimation of Hemoglobin among Children 6-59 Months. Ramaswamy G, Vohra K, Yadav K, Kaur R, Rai T, Jaiswal A, Kant S. J Trop Pediatr; 2021 Jan 29; 67(1):. PubMed ID: 33367788 [Abstract] [Full Text] [Related]
25. Diagnostic accuracy of point-of-care devices for detection of anemia in community settings in India. Neogi SB, Sharma J, Pandey S, Zaidi N, Bhattacharya M, Kar R, Kar SS, Purohit A, Bandyopadhyay S, Saxena R. BMC Health Serv Res; 2020 May 26; 20(1):468. PubMed ID: 32456639 [Abstract] [Full Text] [Related]
26. Comparison of the accuracy of noninvasive hemoglobin monitoring by spectrophotometry (SpHb) and HemoCue® with automated laboratory hemoglobin measurement. Lamhaut L, Apriotesei R, Combes X, Lejay M, Carli P, Vivien B. Anesthesiology; 2011 Sep 26; 115(3):548-54. PubMed ID: 21716091 [Abstract] [Full Text] [Related]
27. Comparison of the accuracy of hemoglobin point of care testing using HemoCue and GEM Premier 3000 with automated hematology analyzer in emergency room. Zatloukal J, Pouska J, Kletecka J, Pradl R, Benes J. J Clin Monit Comput; 2016 Dec 26; 30(6):949-956. PubMed ID: 26507548 [Abstract] [Full Text] [Related]
30. Comparison between the HemoCue and an automated counter for measuring hemoglobin. Paiva Ade A, Rondó PH, Silva SS, Latorre Mdo R. Rev Saude Publica; 2004 Aug 26; 38(4):585-7. PubMed ID: 15311302 [Abstract] [Full Text] [Related]
31. Accuracy of Capillary Hemoglobin Measurements for the Detection of Anemia among U.S. Low-Income Toddlers and Pregnant Women. Boghani S, Mei Z, Perry GS, Brittenham GM, Cogswell ME. Nutrients; 2017 Mar 09; 9(3):. PubMed ID: 28282926 [Abstract] [Full Text] [Related]
32. Hemocue, an accurate bedside method of hemoglobin measurement? Rippmann CE, Nett PC, Popovic D, Seifert B, Pasch T, Spahn DR. J Clin Monit; 1997 Nov 09; 13(6):373-7. PubMed ID: 9495289 [Abstract] [Full Text] [Related]
33. [The new HemoCue system Hb 301 for the haemoglobin measurement in pregnant women]. Tayou Tagny C, Kouam L, Mbanya D. Ann Biol Clin (Paris); 2008 Nov 09; 66(1):90-4. PubMed ID: 18227010 [Abstract] [Full Text] [Related]
34. [Evaluation of a new portable analyzer, HemoCue® Hb801, for hemoglobin point-of-care testing]. Zamorano B, Sakr Y, Galopin-Dubois F. Ann Biol Clin (Paris); 2024 Apr 19; 82(1):103-111. PubMed ID: 38638023 [Abstract] [Full Text] [Related]
35. Comparison of Anemia Screening Methods Using Paired Venous Samples in Women of Reproductive Age in Southern India. Fothergill A, Crider KS, Johnson CB, Raj MP, Guetterman HM, Bose B, Rose CE, Qi YP, Williams JL, Kuriyan R, Bonam W, Finkelstein JL. J Nutr; 2023 Jan 14; 152(12):2978-2992. PubMed ID: 36130238 [Abstract] [Full Text] [Related]
39. Hemoglobin assessment: precision and practicability evaluated in the Netherlands-the HAPPEN study. Baart AM, de Kort WL, van den Hurk K, Pasker-de Jong PC. Transfusion; 2016 Aug 14; 56(8):1984-93. PubMed ID: 26968697 [Abstract] [Full Text] [Related]
40. Comparison of three noninvasive methods for hemoglobin screening of blood donors. Ardin S, Störmer M, Radojska S, Oustianskaia L, Hahn M, Gathof BS. Transfusion; 2015 Feb 14; 55(2):379-87. PubMed ID: 25123051 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]