These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


720 related items for PubMed ID: 29305731

  • 1. Association of Bruch's membrane opening and optic disc morphology to axial length and visual field defects in eyes with primary open-angle glaucoma.
    Nakanishi H, Suda K, Yoshikawa M, Akagi T, Kameda T, Ikeda HO, Yokota S, Kurimoto Y, Tsujikawa A.
    Graefes Arch Clin Exp Ophthalmol; 2018 Mar; 256(3):599-610. PubMed ID: 29305731
    [Abstract] [Full Text] [Related]

  • 2. Novel Bruch's Membrane Opening Minimum Rim Area Equalizes Disc Size Dependency and Offers High Diagnostic Power for Glaucoma.
    Enders P, Adler W, Schaub F, Hermann MM, Dietlein T, Cursiefen C, Heindl LM.
    Invest Ophthalmol Vis Sci; 2016 Dec 01; 57(15):6596-6603. PubMed ID: 27951592
    [Abstract] [Full Text] [Related]

  • 3. The use of Bruch's membrane opening-based optical coherence tomography of the optic nerve head for glaucoma detection in microdiscs.
    Enders P, Schaub F, Adler W, Nikoluk R, Hermann MM, Heindl LM.
    Br J Ophthalmol; 2017 Apr 01; 101(4):530-535. PubMed ID: 27436783
    [Abstract] [Full Text] [Related]

  • 4. Intra- and interobserver reproducibility of Bruch's membrane opening minimum rim width measurements with spectral domain optical coherence tomography.
    Reis ASC, Zangalli CES, Abe RY, Silva AL, Vianna JR, Vasconcellos JPC, Costa VP.
    Acta Ophthalmol; 2017 Nov 01; 95(7):e548-e555. PubMed ID: 28650590
    [Abstract] [Full Text] [Related]

  • 5. Diagnostic Accuracy of Optical Coherence Tomography and Scanning Laser Tomography for Identifying Glaucoma in Myopic Eyes.
    Malik R, Belliveau AC, Sharpe GP, Shuba LM, Chauhan BC, Nicolela MT.
    Ophthalmology; 2016 Jun 01; 123(6):1181-9. PubMed ID: 26992843
    [Abstract] [Full Text] [Related]

  • 6. Comparison of Bruch's Membrane Opening Minimum Rim Width and Peripapillary Retinal Nerve Fiber Layer Thickness in Early Glaucoma Assessment.
    Gmeiner JM, Schrems WA, Mardin CY, Laemmer R, Kruse FE, Schrems-Hoesl LM.
    Invest Ophthalmol Vis Sci; 2016 Jul 01; 57(9):OCT575-84. PubMed ID: 27547890
    [Abstract] [Full Text] [Related]

  • 7. Bruch's membrane opening-based optical coherence tomography of the optic nerve head: a useful diagnostic tool to detect glaucoma in macrodiscs.
    Enders P, Schaub F, Adler W, Hermann MM, Dietlein TS, Cursiefen C, Heindl LM, Medscape.
    Eye (Lond); 2018 Feb 01; 32(2):314-323. PubMed ID: 29386616
    [Abstract] [Full Text] [Related]

  • 8. OCT Segmentation Errors with Bruch's Membrane Opening-Minimum Rim Width as Compared with Retinal Nerve Fiber Layer Thickness.
    Yang H, Rees JP, Sanchez FG, Gardiner SK, Mansberger SL.
    Ophthalmol Glaucoma; 2024 Feb 01; 7(3):308-315. PubMed ID: 38104770
    [Abstract] [Full Text] [Related]

  • 9. Dynamics of structural reversal in Bruch's membrane opening-based morphometrics after glaucoma drainage device surgery.
    Gietzelt C, von Goscinski C, Lemke J, Schaub F, Hermann MM, Dietlein TS, Cursiefen C, Heindl LM, Enders P.
    Graefes Arch Clin Exp Ophthalmol; 2020 Jun 01; 258(6):1227-1236. PubMed ID: 32140925
    [Abstract] [Full Text] [Related]

  • 10. Accuracy of Bruch's membrane opening minimum rim width and retinal nerve fiber layer thickness in glaucoma diagnosis depending on optic disc size.
    Englmaier VA, Storp JJ, Leclaire MD, Lahme L, Brücher VC, Biermann J, Diener R, Eter N.
    Graefes Arch Clin Exp Ophthalmol; 2024 Jun 01; 262(6):1899-1910. PubMed ID: 38240777
    [Abstract] [Full Text] [Related]

  • 11. Effect of optic disc size on correlation between Bruch's membrane opening-minimum rim width and peripapillary retinal nerve fibre layer thickness.
    Cho HK, Park JM, Kee C.
    Eye (Lond); 2019 Dec 01; 33(12):1930-1938. PubMed ID: 31285571
    [Abstract] [Full Text] [Related]

  • 12. Structure-function relationship between Bruch's membrane opening-minimum rim width and perimetry in open-angle glaucoma subtypes.
    Li R, Wang X, Wei Y, Fang Y, Tian T, Li M, Cai Y, Pan Y.
    Graefes Arch Clin Exp Ophthalmol; 2020 Mar 01; 258(3):595-605. PubMed ID: 31823058
    [Abstract] [Full Text] [Related]

  • 13. Comparing optical coherence tomography radial and cube scan patterns for measuring Bruch's membrane opening minimum rim width (BMO-MRW) in glaucoma and healthy eyes: cross-sectional and longitudinal analysis.
    Kabbara SW, Zangwill LM, Mundae R, Hammel N, Bowd C, Medeiros FA, Weinreb RN, Belghith A.
    Br J Ophthalmol; 2018 Mar 01; 102(3):344-351. PubMed ID: 28774935
    [Abstract] [Full Text] [Related]

  • 14. Evaluation of two-dimensional Bruch's membrane opening minimum rim area for glaucoma diagnostics in a large patient cohort.
    Enders P, Adler W, Kiessling D, Weber V, Schaub F, Hermann MM, Dietlein T, Cursiefen C, Heindl LM.
    Acta Ophthalmol; 2019 Feb 01; 97(1):60-67. PubMed ID: 29575745
    [Abstract] [Full Text] [Related]

  • 15. Bruch's Membrane Opening-Minimum Rim Width Assessment With Spectral-Domain Optical Coherence Tomography Performs Better Than Confocal Scanning Laser Ophthalmoscopy in Discriminating Early Glaucoma Patients From Control Subjects.
    Toshev AP, Lamparter J, Pfeiffer N, Hoffmann EM.
    J Glaucoma; 2017 Jan 01; 26(1):27-33. PubMed ID: 27636592
    [Abstract] [Full Text] [Related]

  • 16. Differences in Retinal Nerve Fiber Layer Thickness as Assessed on the Disc Center and Bruch's Membrane Opening Center in Myopic Eyes.
    Sawada Y, Araie M, Shibata H, Ishikawa M, Iwata T, Yoshitomi T.
    Ophthalmol Glaucoma; 2019 Jan 01; 2(3):145-155. PubMed ID: 32672582
    [Abstract] [Full Text] [Related]

  • 17. Glaucoma Diagnostic Ability of the New Circumpapillary Retinal Nerve Fiber Layer Thickness Analysis Based on Bruch's Membrane Opening.
    Lee EJ, Lee KM, Kim H, Kim TW.
    Invest Ophthalmol Vis Sci; 2016 Aug 01; 57(10):4194-204. PubMed ID: 27548890
    [Abstract] [Full Text] [Related]

  • 18. Structural Reversal of Disc Cupping After Trabeculectomy Alters Bruch Membrane Opening-Based Parameters to Assess Neuroretinal Rim.
    Gietzelt C, Lemke J, Schaub F, Hermann MM, Dietlein TS, Cursiefen C, Enders P, Heindl LM.
    Am J Ophthalmol; 2018 Oct 01; 194():143-152. PubMed ID: 30053469
    [Abstract] [Full Text] [Related]

  • 19. Size and Shape of Bruch's Membrane Opening in Relationship to Axial Length, Gamma Zone, and Macular Bruch's Membrane Defects.
    Zhang Q, Xu L, Wei WB, Wang YX, Jonas JB.
    Invest Ophthalmol Vis Sci; 2019 Jun 03; 60(7):2591-2598. PubMed ID: 31219533
    [Abstract] [Full Text] [Related]

  • 20. Effects of Deep Optic Nerve Head Structures on Bruch's Membrane Opening- Minimum Rim Width and Peripapillary Retinal Nerve Fiber Layer.
    Kambayashi M, Saito H, Araie M, Enomoto N, Murata H, Kikawa T, Sugiyama K, Higashide T, Miki A, Iwase A, Tomita G, Nakazawa T, Aihara M, Ohno-Matsui K, Kim TW, Leung CKS, Zangwill LM, Weinreb RN.
    Am J Ophthalmol; 2024 Jul 03; 263():99-108. PubMed ID: 38403100
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 36.