These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


109 related items for PubMed ID: 2942156

  • 1. Biocompatibility of a new polycarbonate dialysis membrane.
    Knudsen F, Nielsen AH, Pedersen JO, Grunnet N, Jersild C.
    Blood Purif; 1986; 4(1-3):142-6. PubMed ID: 2942156
    [Abstract] [Full Text] [Related]

  • 2. Performance and biocompatibility of a new hemodialysis membrane.
    von Herrath D, Dati F, Pelzer H, Hartenstein K, Kutschera D, Schaefer K.
    Blood Purif; 1986; 4(1-3):151-8. PubMed ID: 3637111
    [Abstract] [Full Text] [Related]

  • 3. Anaphylatoxin C5a generation and dialysis-induced leukopenia with different hemodialyzer membranes.
    Aljama P, Martín-Malo A, Castillo D, Velasco F, Torres A, Pérez R, Castro M.
    Blood Purif; 1986; 4(1-3):88-92. PubMed ID: 3730166
    [Abstract] [Full Text] [Related]

  • 4. Biocompatibility and hemodynamic studies during polycarbonate versus cuprophane membrane dialysis.
    Schohn DC, Jahn HA, Eber M, Hauptmann G.
    Blood Purif; 1986; 4(1-3):102-11. PubMed ID: 3730154
    [Abstract] [Full Text] [Related]

  • 5. Assessment of complement activation during extracorporeal circulation by measurement of complement split C3d.
    Knudsen F.
    Blood Purif; 1987; 5(2-3):162-7. PubMed ID: 3497646
    [Abstract] [Full Text] [Related]

  • 6. The polycarbonate hemodialysis membrane: neutrophil, platelet, complement and chemiluminescence kinetics during first and second use.
    Heierli C, Markert M, Frei J, Lambert PH, Wauters JP.
    Blood Purif; 1986; 4(1-3):82-7. PubMed ID: 3730165
    [Abstract] [Full Text] [Related]

  • 7. On the kinetics of complement activation, leucopenia and granulocyte-elastase release induced by haemodialysis.
    Knudsen F, Nielsen AH, Pedersen JO, Jersild C.
    Scand J Clin Lab Invest; 1985 Dec; 45(8):759-66. PubMed ID: 3878572
    [Abstract] [Full Text] [Related]

  • 8. Granulocyte elastase, beta-thromboglobulin, and C3d during acetate or bicarbonate hemodialysis with Hemophan compared to a cellulose acetate membrane.
    Stegmayr BG, Esbensen K, Gutierrez A, Lundberg L, Nielsen B, Stroemsaeter CE, Wehle B.
    Int J Artif Organs; 1992 Jan; 15(1):10-8. PubMed ID: 1532382
    [Abstract] [Full Text] [Related]

  • 9. Adult respiratory distress-like syndrome during hemodialysis: relationship between activation of complement, leukopenia, and release of granulocyte elastase.
    Knudsen F, Nielsen AH, Pedersen JO, Grunnet N, Jersild C.
    Int J Artif Organs; 1985 Jul; 8(4):187-94. PubMed ID: 3850856
    [Abstract] [Full Text] [Related]

  • 10. Evaluation and tolerance of a new polycarbonate membrane in elderly patients. Preliminary results.
    Forêt M, Hachache T, Alibeu C, Kuentz F, Meftahi H.
    Blood Purif; 1986 Jul; 4(1-3):159-67. PubMed ID: 3488067
    [Abstract] [Full Text] [Related]

  • 11. Plasma levels of main granulocyte components in patients dialyzed with polycarbonate and cuprophan membranes.
    Hörl WH, Riegel W, Schollmeyer P.
    Nephron; 1987 Jul; 45(4):272-6. PubMed ID: 3035392
    [Abstract] [Full Text] [Related]

  • 12. Dialysis membranes and coagulation system.
    Notohamiprodjo M, Andrassy K, Bommer J, Ritz E.
    Blood Purif; 1986 Jul; 4(1-3):130-41. PubMed ID: 2942155
    [Abstract] [Full Text] [Related]

  • 13. Patient reactions and granulocyte degranulation during hemodialysis with cuprophane and polycarbonate membranes. A double-blind study.
    Danielson BG, Hällgren R, Venge P.
    Blood Purif; 1986 Jul; 4(1-3):147-50. PubMed ID: 3524607
    [Abstract] [Full Text] [Related]

  • 14. Good biocompatibility of the polyamide hemofilter.
    von Herrath D, Hüfler M, Hartenstein-Koch K, Kutschera D, Schaefer K, Dati F.
    Blood Purif; 1988 Jul; 6(2):106-10. PubMed ID: 3395472
    [Abstract] [Full Text] [Related]

  • 15. Preliminary report on complement activating potential of polycarbonate membrane.
    Henderson LW, Chenoweth DE, Shinaberger JH, Miller J, Konstantin P.
    Blood Purif; 1986 Jul; 4(1-3):74-81. PubMed ID: 3730164
    [Abstract] [Full Text] [Related]

  • 16. Biocompatibility of a polycarbonate membrane. A preliminary report.
    De Broe ME, van Waeleghem JP, Heyrman R, De Backer W.
    Blood Purif; 1986 Jul; 4(1-3):168-71. PubMed ID: 3015165
    [Abstract] [Full Text] [Related]

  • 17. [Criteria of the biocompatibility of the membranes used in dialysis].
    Stratta P, Canavese C, Segoloni GP, Dogliani M, Racca M, Coppo R, Vercellone A.
    Minerva Nefrol; 1981 Jul; 28(2):109-11. PubMed ID: 6457263
    [No Abstract] [Full Text] [Related]

  • 18. Cellulose membranes--time for a change?
    Henderson LW, Chenoweth DE.
    Contrib Nephrol; 1985 Jul; 44():112-26. PubMed ID: 3872769
    [No Abstract] [Full Text] [Related]

  • 19. Biocompatibility of different hemodialysis and plasmapheresis membranes.
    Jørstad S.
    Blood Purif; 1987 Jul; 5(2-3):123-37. PubMed ID: 3497645
    [Abstract] [Full Text] [Related]

  • 20. Complement C3 and C5 degradation products during hemodialysis treatment: study of an index of membrane bioincompatibility.
    Freyria AM, Leitienne P, Veysseyre CN, Bringuier JP, Traeger J.
    Int J Artif Organs; 1988 Mar; 11(2):111-8. PubMed ID: 3259552
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 6.