These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
946 related items for PubMed ID: 29446668
1. Improved Opacification of a Suboptimally Enhanced Pulmonary Artery in Chest CT: Experience Using a Dual-Layer Detector Spectral CT. Bae K, Jeon KN, Cho SB, Park SE, Moon JI, Baek HJ, Choi BH. AJR Am J Roentgenol; 2018 Apr; 210(4):734-741. PubMed ID: 29446668 [Abstract] [Full Text] [Related]
2. Evaluation of Virtual Monoenergetic Images on Pulmonary Vasculature Using the Dual-Layer Detector-Based Spectral Computed Tomography. Ghandour A, Sher A, Rassouli N, Dhanantwari A, Rajiah P. J Comput Assist Tomogr; 2018 Apr; 42(6):858-865. PubMed ID: 29659426 [Abstract] [Full Text] [Related]
3. Assessment of 70-keV virtual monoenergetic spectral images in abdominal CT imaging: A comparison study to conventional polychromatic 120-kVp images. Rassouli N, Chalian H, Rajiah P, Dhanantwari A, Landeras L. Abdom Radiol (NY); 2017 Oct; 42(10):2579-2586. PubMed ID: 28421243 [Abstract] [Full Text] [Related]
4. Image Quality on Dual-energy CTPA Virtual Monoenergetic Images: Quantitative and Qualitative Assessment. Dane B, Patel H, O'Donnell T, Girvin F, Brusca-Augello G, Alpert JB, Niu B, Attia M, Babb J, Ko JP. Acad Radiol; 2018 Aug; 25(8):1075-1086. PubMed ID: 29398436 [Abstract] [Full Text] [Related]
5. Value of monoenergetic low-kV dual energy CT datasets for improved image quality of CT pulmonary angiography. Apfaltrer P, Sudarski S, Schneider D, Nance JW, Haubenreisser H, Fink C, Schoenberg SO, Henzler T. Eur J Radiol; 2014 Feb; 83(2):322-8. PubMed ID: 24361061 [Abstract] [Full Text] [Related]
9. Noise-optimized advanced image-based virtual monoenergetic imaging for improved visualization of lung cancer: Comparison with traditional virtual monoenergetic imaging. Frellesen C, Kaup M, Wichmann JL, Hüsers K, Scholtz JE, Albrecht MH, Metzger SC, Bauer RW, Kerl JM, Lehnert T, Vogl TJ, Bodelle B. Eur J Radiol; 2016 Mar; 85(3):665-72. PubMed ID: 26860682 [Abstract] [Full Text] [Related]
10. Improved coronary artery contrast enhancement using noise-optimised virtual monoenergetic imaging from dual-source dual-energy computed tomography. Arendt CT, Czwikla R, Lenga L, Wichmann JL, Albrecht MH, Booz C, Martin SS, Leithner D, Tischendorf P, Blandino A, Vogl TJ, D'Angelo T. Eur J Radiol; 2020 Jan; 122():108666. PubMed ID: 31786506 [Abstract] [Full Text] [Related]
11. Utility of virtual monoenergetic images derived from a dual-layer detector-based spectral CT in the assessment of aortic anatomy and pathology: A retrospective case control study. Chalian H, Kalisz K, Rassouli N, Dhanantwari A, Rajiah P. Clin Imaging; 2018 Jan; 52():292-301. PubMed ID: 30212800 [Abstract] [Full Text] [Related]
15. Optimization of kiloelectron volt settings in cerebral and cervical dual-energy CT angiography determined with virtual monoenergetic imaging. Schneider D, Apfaltrer P, Sudarski S, Nance JW, Haubenreisser H, Fink C, Schoenberg SO, Henzler T. Acad Radiol; 2014 Apr; 21(4):431-6. PubMed ID: 24594412 [Abstract] [Full Text] [Related]
16. Virtual Monoenergetic Imaging and Iodine Perfusion Maps Improve Diagnostic Accuracy of Dual-Energy Computed Tomography Pulmonary Angiography With Suboptimal Contrast Attenuation. Leithner D, Wichmann JL, Vogl TJ, Trommer J, Martin SS, Scholtz JE, Bodelle B, De Cecco CN, Duguay T, Nance JW, Schoepf UJ, Albrecht MH. Invest Radiol; 2017 Nov; 52(11):659-665. PubMed ID: 28542094 [Abstract] [Full Text] [Related]
17. Initial Clinical Experience of Virtual Monoenergetic Imaging Improves Stent Visualization in Lower Extremity Run-Off CT Angiography by Dual-Layer Spectral Detector CT. Zhang D, Xie Y, Wang Y, Guo N, Wang Y, Jin Z, Xue H. Acad Radiol; 2020 Jun; 27(6):825-832. PubMed ID: 31623997 [Abstract] [Full Text] [Related]
18. Dual-Layer Spectral CTA for TAVI Planning Using a Split-Phase Protocol and Low-keV Virtual Monoenergetic Images: Improved Image Quality in Comparison with Single-Phase Conventional CTA. Mangold D, Salatzki J, Riffel J, Kauczor HU, Weber TF. Rofo; 2022 Jun; 194(6):652-659. PubMed ID: 34963190 [Abstract] [Full Text] [Related]
19. Noise-optimized virtual monoenergetic dual-energy computed tomography: optimization of kiloelectron volt settings in patients with gastrointestinal stromal tumors. Martin SS, Pfeifer S, Wichmann JL, Albrecht MH, Leithner D, Lenga L, Scholtz JE, Vogl TJ, Bodelle B. Abdom Radiol (NY); 2017 Mar; 42(3):718-726. PubMed ID: 27999889 [Abstract] [Full Text] [Related]
20. Assessment of an advanced image-based technique to calculate virtual monoenergetic computed tomographic images from a dual-energy examination to improve contrast-to-noise ratio in examinations using iodinated contrast media. Grant KL, Flohr TG, Krauss B, Sedlmair M, Thomas C, Schmidt B. Invest Radiol; 2014 Sep; 49(9):586-92. PubMed ID: 24710203 [Abstract] [Full Text] [Related] Page: [Next] [New Search]