These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


177 related items for PubMed ID: 2950039

  • 1. Doppler ultrasound examination of prosthetic function and ventricular blood flow after mitral valve replacement.
    Omoto R, Matsumura M, Asano H, Kyo S, Takamoto S, Yokote Y, Wong M.
    Herz; 1986 Dec; 11(6):346-50. PubMed ID: 2950039
    [Abstract] [Full Text] [Related]

  • 2. [Continuous wave Doppler assessment of prosthetic valves in the mitral position: comparison of the St. Jude medical mechanical valve and the porcine xenograft valve].
    Kisanuki A, Tei C, Arikawa K, Natsugoe K, Otsuji Y, Kawazoe Y, Tanaka H, Morishita Y, Maruko M, Taira A.
    J Cardiogr; 1985 Dec; 15(4):1119-27. PubMed ID: 3841894
    [Abstract] [Full Text] [Related]

  • 3. [Intracardiac flow dynamic alterations with a prosthetic mitral valve studied by pulsed Doppler technique].
    Kitabatake A, Tanouchi J, Asao M, Mishima M, Ishihara K, Masuyama T, Inoue M, Abe H, Matsuo H, Morita H.
    J Cardiogr; 1985 Jun; 15(2):469-82. PubMed ID: 4093627
    [Abstract] [Full Text] [Related]

  • 4. [Doppler evaluation of porcine mitral valve dysfunction].
    Nakamura K, Matsumura K, Satomi G, Sakai K, Ishizuka N, Mori K, Shiina T, Kikuchi N, Hirosawa K, Takao A.
    J Cardiogr; 1986 Dec; 16(4):929-39. PubMed ID: 3429909
    [Abstract] [Full Text] [Related]

  • 5. [Doppler echocardiography in assessing mechanical and biological heart valve prostheses].
    Minardi G, Di Segni M, Boccardi L, Ferrari O, Giovannini E.
    G Ital Cardiol; 1988 Feb; 18(2):121-34. PubMed ID: 3410201
    [Abstract] [Full Text] [Related]

  • 6. [Non-invasive estimation of transmitral pressure gradient and mitral valve area in mitral stenosis by an ultrasonic pulsed Doppler technique].
    Asao M, Kitabatake A, Inoue M, Tanouchi J, Morita T, Masuyama T, Mishima M, Shimazu T, Ishihara K, Fujii K.
    J Cardiogr; 1984 Jun; 14(1):149-61. PubMed ID: 6240509
    [Abstract] [Full Text] [Related]

  • 7. [Continuous wave Doppler echocardiographic assessment of prosthetic aortic valves].
    Kisanuki A, Tei C, Arikawa K, Otsuji Y, Kawazoe Y, Natsugoe K, Tanaka H, Morishita Y, Taira A.
    J Cardiogr; 1986 Mar; 16(1):121-32. PubMed ID: 3782875
    [Abstract] [Full Text] [Related]

  • 8. [Usefulness of magnetic resonance imaging for managing patients with prosthetic carbon valve in the mitral position].
    Koito H, Imai Y, Suzuki J, Ohkubo N, Nakamura C, Takahashi H, Iwasaka T, Inada M.
    J Cardiol; 1997 Nov; 30(5):251-63. PubMed ID: 9395956
    [Abstract] [Full Text] [Related]

  • 9. In vitro assessment of prosthetic valve function in mitral valve replacement with chordal preservation techniques.
    Fontaine AA, He S, Stadter R, Ellis JT, Levine RA, Yoganathan AP.
    J Heart Valve Dis; 1996 Mar; 5(2):186-98. PubMed ID: 8665014
    [Abstract] [Full Text] [Related]

  • 10. [Pulsed Doppler echocardiography in prosthetic aortic and mitral valve replacement].
    Mattern H, Fricke G.
    Klin Wochenschr; 1986 Jan 15; 64(2):76-85. PubMed ID: 3951167
    [Abstract] [Full Text] [Related]

  • 11. [Normally functioning mitral prosthesis: visualization and characterization of the trans-valvular flow using color-coded Doppler].
    Moro E, Pignoni P, Nicolosi GL, Dall'Aglio V, Sparacino L, Pavan D, Lestuzzi C, Zanuttini D.
    G Ital Cardiol; 1988 Mar 15; 18(3):198-205. PubMed ID: 3169468
    [Abstract] [Full Text] [Related]

  • 12. [Noninvasive assessment of an aortic bioprosthesis malfunction with Doppler echocardiography].
    Fischer JL, Henselmann L.
    Z Kardiol; 1987 May 15; 76(5):309-14. PubMed ID: 3617871
    [Abstract] [Full Text] [Related]

  • 13. [Two-dimensional echo-cardiographic study on left atrial thrombi in patients with a mitral prosthetic valve].
    Tsuyuguchi N, Shigeta H, Hashimoto M, Tamagawa M, Yokode M, Tanaka M, Suwo M, Yokota Y.
    J Cardiogr; 1983 Dec 15; 13(4):923-33. PubMed ID: 6678957
    [Abstract] [Full Text] [Related]

  • 14. [Pulsed Doppler echocardiographic observation of right and left ventricular inflow velocity patterns in various types of arrhythmia, with special reference to the mechanism of atrioventricular regurgitation].
    Oki T, Asai M, Takemura H, Fukuda N, Sakai H, Ohshima C, Tominaga T, Taoka M, Niki T, Mori H.
    J Cardiogr; 1983 Sep 15; 13(3):617-31. PubMed ID: 6205099
    [Abstract] [Full Text] [Related]

  • 15. [Doppler sonographic determination of the degree of severity of mitral valve stenoses].
    Niehues B, Schwarzenbart E, Neufeind A, Hilger HH.
    Z Kardiol; 1985 Jan 15; 74(1):23-31. PubMed ID: 3976260
    [Abstract] [Full Text] [Related]

  • 16. Influence of a tilting prosthetic mitral valve orientation on the left ventricular flow - an experimental in vivo magnetic resonance imaging study.
    Mächler H, Reiter G, Perthel M, Reiter U, Bergmann P, Zink M, Rienmüller R, Laas J.
    Eur J Cardiothorac Surg; 2007 Jul 15; 32(1):102-7. PubMed ID: 17419068
    [Abstract] [Full Text] [Related]

  • 17. Imaging of the orifice of the left ventricular outflow tract: technique and initial results.
    Komoda T, Hetzer R, Oellinger J, Siniawski H, Hofmeister J, Hübler M, Felix R, Uyama C, Maeta H.
    Technol Health Care; 1997 Jul 15; 5(3):207-17. PubMed ID: 9263370
    [Abstract] [Full Text] [Related]

  • 18. Left ventricular outflow obstruction after mitral valve repair (Carpentier's technique). Proposed mechanisms of disease.
    Mihaileanu S, Marino JP, Chauvaud S, Perier P, Forman J, Vissoat J, Julien J, Dreyfus G, Abastado P, Carpentier A.
    Circulation; 1988 Sep 15; 78(3 Pt 2):I78-84. PubMed ID: 3409521
    [Abstract] [Full Text] [Related]

  • 19. The orientation of the bi-leaflet CarboMedics valve in the mitral position determines left ventricular spatial flow patterns.
    Van Rijk-Zwikker GL, Delemarre BJ, Huysmans HA.
    Eur J Cardiothorac Surg; 1996 Sep 15; 10(7):513-20. PubMed ID: 8855422
    [Abstract] [Full Text] [Related]

  • 20. [Blood flow patterns in the left ventricle in patients with myocardial infarction and ventricular aneurysm: evaluation using real-time two-dimensional Doppler echocardiography].
    Konishiike A, Mihata S, Matsumori Y, Nishian K, Ikeoka K, Yasutomi N, Tanimoto M, Makihata S, Yamamoto T, Iwasaki T.
    J Cardiol; 1987 Dec 15; 17(4):671-82. PubMed ID: 3506597
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 9.