These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
238 related items for PubMed ID: 29630873
1. The Incidence and Consequence of Prosthesis-Patient Mismatch After Surgical Aortic Valve Replacement. Fallon JM, DeSimone JP, Brennan JM, O'Brien S, Thibault DP, DiScipio AW, Pibarot P, Jacobs JP, Malenka DJ. Ann Thorac Surg; 2018 Jul; 106(1):14-22. PubMed ID: 29630873 [Abstract] [Full Text] [Related]
2. Severe prosthesis-patient mismatch after aortic valve replacement for aortic stenosis: Analysis of risk factors for early and long-term mortality. Mannacio V, Mannacio L, Mango E, Antignano A, Mottola M, Caparrotti S, Musumeci F, Vosa C. J Cardiol; 2017 Jan; 69(1):333-339. PubMed ID: 27492659 [Abstract] [Full Text] [Related]
5. Patient-Prosthesis Mismatch Worsens Long-Term Survival: Insights From the FinnValve Registry. Dahlbacka S, Laakso T, Kinnunen EM, Moriyama N, Laine M, Virtanen M, Maaranen P, Ahvenvaara T, Tauriainen T, Husso A, Jalava M, Jaakkola J, Airaksinen J, Valtola A, Niemelä M, Mäkikallio T, Eskola M, Vento A, Juvonen T, Biancari F, Raivio P. Ann Thorac Surg; 2021 Apr; 111(4):1284-1290. PubMed ID: 32805269 [Abstract] [Full Text] [Related]
6. Moderate patient-prosthesis mismatch predicts cardiac events and advanced functional class in young and middle-aged patients undergoing surgery due to severe aortic stenosis. Hernandez-Vaquero D, Garcia JM, Diaz R, Calvo D, Khalpey Z, Hernández E, Rodriguez V, Morís C, Llosa JC. J Card Surg; 2014 Mar; 29(2):127-33. PubMed ID: 24330010 [Abstract] [Full Text] [Related]
10. Impact of Pre-Existing Prosthesis-Patient Mismatch on Survival Following Aortic Valve-in-Valve Procedures. Pibarot P, Simonato M, Barbanti M, Linke A, Kornowski R, Rudolph T, Spence M, Moat N, Aldea G, Mennuni M, Iadanza A, Amrane H, Gaia D, Kim WK, Napodano M, Baumbach H, Finkelstein A, Kobayashi J, Brecker S, Don C, Cerillo A, Unbehaun A, Attias D, Nejjari M, Jones N, Fiorina C, Tchetche D, Philippart R, Spargias K, Hernandez JM, Latib A, Dvir D. JACC Cardiovasc Interv; 2018 Jan 22; 11(2):133-141. PubMed ID: 29348008 [Abstract] [Full Text] [Related]
12. Indexed effective orifice area is a significant predictor of higher mid- and long-term mortality rates following aortic valve replacement in patients with prosthesis-patient mismatch. Chen J, Lin Y, Kang B, Wang Z. Eur J Cardiothorac Surg; 2014 Feb 22; 45(2):234-40. PubMed ID: 23682010 [Abstract] [Full Text] [Related]
13. Long-term outcomes after valve replacement for low-gradient aortic stenosis: impact of prosthesis-patient mismatch. Kulik A, Burwash IG, Kapila V, Mesana TG, Ruel M. Circulation; 2006 Jul 04; 114(1 Suppl):I553-8. PubMed ID: 16820636 [Abstract] [Full Text] [Related]
20. Twenty-year durability of the aortic Hancock II bioprosthesis in young patients: is it durable enough? Une D, Ruel M, David TE. Eur J Cardiothorac Surg; 2014 Nov 04; 46(5):825-30. PubMed ID: 24510909 [Abstract] [Full Text] [Related] Page: [Next] [New Search]