These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


154 related items for PubMed ID: 29666554

  • 21. The impact of different sample matrices in delayed measurement of glucose.
    Roccaforte V, Daves M, Platzgummer S, Lippi G.
    Clin Biochem; 2016 Dec; 49(18):1412-1415. PubMed ID: 27567939
    [Abstract] [Full Text] [Related]

  • 22. Which sample tube should be used for routine glucose determination?
    Bonetti G, Cancelli V, Coccoli G, Piccinelli G, Brugnoni D, Caimi L, Carta M.
    Prim Care Diabetes; 2016 Jun; 10(3):227-32. PubMed ID: 26657574
    [Abstract] [Full Text] [Related]

  • 23. Comparison of digoxin concentration in plastic serum tubes with clot activator and heparinized plasma tubes.
    Dukić L, Simundić AM, Malogorski D.
    Biochem Med (Zagreb); 2014 Jun; 24(1):146-50. PubMed ID: 24627723
    [Abstract] [Full Text] [Related]

  • 24. Clinical impact of citrate-containing tubes on the detection of glucose abnormalities by the oral glucose tolerance test.
    Bonetti G, Giavarina D, Carta M.
    Diagnosis (Berl); 2019 Nov 26; 6(4):377-383. PubMed ID: 30875321
    [Abstract] [Full Text] [Related]

  • 25. Contamination of lithium heparin blood by K2-ethylenediaminetetraacetic acid (EDTA): an experimental evaluation.
    Lima-Oliveira G, Salvagno GL, Danese E, Brocco G, Guidi GC, Lippi G.
    Biochem Med (Zagreb); 2014 Nov 26; 24(3):359-67. PubMed ID: 25351354
    [Abstract] [Full Text] [Related]

  • 26. The influence of anticoagulants on the measurement of total protein concentration in equine peritoneal fluid.
    Estepa JC, Lopez I, Mayer-Valor R, Rodriguez M, Aguilera-Tejero E.
    Res Vet Sci; 2006 Feb 26; 80(1):5-10. PubMed ID: 15949830
    [Abstract] [Full Text] [Related]

  • 27. Stability of glucose in plasma with different anticoagulants.
    Fobker M.
    Clin Chem Lab Med; 2014 Jul 26; 52(7):1057-60. PubMed ID: 24633752
    [Abstract] [Full Text] [Related]

  • 28. Technical note: Effect of delayed analysis of cooled lithium-heparinized whole blood on the stability of ionized calcium, ionized magnesium, sodium, potassium, chloride, glucose, and lactate in samples from dairy cows.
    Menta PR, Batchelder TA, Neves RC.
    J Dairy Sci; 2020 Jun 26; 103(6):5509-5513. PubMed ID: 32307153
    [Abstract] [Full Text] [Related]

  • 29. Comparison of BD Vacutainer® Rapid Serum Tube and plasma for haemolysis markers in the emergency department.
    Ryan JB, Stuart LA, Southby SJ, Than MP, Mackay R, Florkowski CM, George PM.
    Ann Clin Biochem; 2015 Mar 26; 52(Pt 2):293-6. PubMed ID: 24714681
    [Abstract] [Full Text] [Related]

  • 30. Evaluation of NGAL TestTM on Cobas 6000.
    Hansen YB, Damgaard A, Poulsen JH.
    Scand J Clin Lab Invest; 2014 Jan 26; 74(1):20-6. PubMed ID: 24228725
    [Abstract] [Full Text] [Related]

  • 31. Recentrifugation of Lithium Heparin Gel Separator Tubes up to 8 h after Blood Collection Has No Relevant Influence on the Stability of 30 Routine Biochemical Analytes.
    van Balveren JA, Gemen EFA, Kusters R.
    J Appl Lab Med; 2019 Mar 26; 3(5):864-869. PubMed ID: 31639761
    [Abstract] [Full Text] [Related]

  • 32. Effect of collection tube type and freeze-thaw cycles on myeloperoxidase concentrations in blood samples of acute coronary syndrome patients.
    Naz S, Ghafoor F, Iqbal IA.
    Ann Clin Biochem; 2017 May 26; 54(3):348-354. PubMed ID: 27422133
    [Abstract] [Full Text] [Related]

  • 33. Glucose Stability Study: NaF/Citrate Plasma Versus Serum.
    Zhang X, Rong C, Li H, Qin X, Li S, Lai Z, Chen X.
    Clin Lab; 2016 May 26; 62(3):389-93. PubMed ID: 27156328
    [Abstract] [Full Text] [Related]

  • 34. Effect of anticoagulants on plasma homocysteine determination.
    Calişkan S, Kuralay F, Onvural B.
    Clin Chim Acta; 2001 Jul 05; 309(1):53-6. PubMed ID: 11408006
    [Abstract] [Full Text] [Related]

  • 35. Sample matrix and high-sensitivity cardiac troponin I assays.
    Kavsak PA, Roy C, Malinowski P, Clark L, Lamers S, Bamford K, Hill S, Worster A, Jaffe AS.
    Clin Chem Lab Med; 2019 Apr 24; 57(5):745-751. PubMed ID: 30838842
    [Abstract] [Full Text] [Related]

  • 36. A Comparison Study: Possible Bias in Troponin I Measurement Obtained with a Point of Care Testing and a Central Laboratory Analyzers Employing Different Biological Matrices and Anticoagulants.
    Sammartano A, Buonocore R, Fiorini R, Dieci E, Di Franco A, Di Stasi B, Tortorella G, Ippolito L.
    Diagnostics (Basel); 2024 Jul 10; 14(14):. PubMed ID: 39061619
    [Abstract] [Full Text] [Related]

  • 37. Determination of endocannabinoids and endocannabinoid-like substances in human K3EDTA plasma - LC-MS/MS method validation and pre-analytical characteristics.
    Gurke R, Thomas D, Schreiber Y, Schäfer SMG, Fleck SC, Geisslinger G, Ferreirós N.
    Talanta; 2019 Nov 01; 204():386-394. PubMed ID: 31357310
    [Abstract] [Full Text] [Related]

  • 38. Impact of under-filled blood collection tubes containing K2EDTA and K3EDTA as anticoagulants on automated complete blood count (CBC) testing.
    Biljak VR, Božičević S, Krhač M, Lovrenčić MV.
    Clin Chem Lab Med; 2016 Nov 01; 54(11):e323-e326. PubMed ID: 27028737
    [No Abstract] [Full Text] [Related]

  • 39. Pneumatic tube-transported blood samples in lithium heparinate gel separator tubes may be more susceptible to haemolysis than blood samples in serum tubes.
    Böckel-Frohnhöfer N, Hübner U, Hummel B, Geisel J.
    Scand J Clin Lab Invest; 2014 Oct 01; 74(7):599-602. PubMed ID: 24909156
    [Abstract] [Full Text] [Related]

  • 40.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]
    of 8.