These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
156 related items for PubMed ID: 29666561
61. Underfilling of vacuum blood collection tubes leads to increased lactate dehydrogenase activity in serum and heparin plasma samples. Neuwinger N, Meyer Zum Büschenfelde D, Tauber R, Kappert K. Clin Chem Lab Med; 2020 Jan 28; 58(2):213-221. PubMed ID: 31665108 [Abstract] [Full Text] [Related]
62. A practical and novel method to extract genomic DNA from blood collection kits for plasma protein preservation. Waters J, Dhere V, Benjamin A, Sekar A, Kumar A, Prahalad S, Okou DT, Kugathasan S. J Vis Exp; 2013 May 18; (75):e4241. PubMed ID: 23711730 [Abstract] [Full Text] [Related]
63. Transport and temperature effects on measurement of serum and plasma potassium. Seamark D, Backhouse S, Barber P, Hichens J, Salzmann M, Powell R. J R Soc Med; 1999 Jul 18; 92(7):339-41. PubMed ID: 10615270 [Abstract] [Full Text] [Related]
64. Pre-analytical effects of different lithium heparin plasma separation tubes in the routine clinical chemistry laboratory. Brandhorst G, Engelmayer J, Götze S, Oellerich M, von Ahsen N. Clin Chem Lab Med; 2011 Sep 18; 49(9):1473-7. PubMed ID: 21605014 [Abstract] [Full Text] [Related]
65. Evaluation of a novel heparin-iloprost-based antithrombotic formulation blood collection tube for clinical usage. Radziwon-Balicka A, Wiwe EF, Jensen TØ, Nielsen SG, Copois M, Sunde N, Peytz NC, Al-Mousawi DAA, Hansen MC, Petersen JF, Nørskov AS, Lendorf ME, Hansen YBL, Hansen TS, Burkhardt MA, Hansen KM, Jensen CAJ. Clin Chim Acta; 2022 Dec 01; 537():87-95. PubMed ID: 36279940 [Abstract] [Full Text] [Related]
66. Measurement of Type B natriuretic peptide in heparin and K(2) EDTA plasma. Daves M, Pusceddu I, Cemin R. Clin Biochem; 2010 Mar 01; 43(4-5):483-4. PubMed ID: 19944086 [Abstract] [Full Text] [Related]
72. Post-analytical stability of 23 common chemistry and immunochemistry analytes in incurred samples. Nielsen BK, Frederiksen T, Friis-Hansen L, Larsen PB. Clin Biochem; 2017 Dec 26; 50(18):1175-1182. PubMed ID: 28803962 [Abstract] [Full Text] [Related]
73. Comparison of glucose determinations on blood samples collected in three types of tubes. Li G, Cabanero M, Wang Z, Wang H, Huang T, Alexis H, Eid I, Muth G, Pincus MR. Ann Clin Lab Sci; 2013 Dec 26; 43(3):278-84. PubMed ID: 23884222 [Abstract] [Full Text] [Related]
74. Agreement between troponin T levels from plain and heparinized tubes. Jones PG, McClelland A, McNeil A, Gamble G. Emerg Med (Fremantle); 2001 Dec 26; 13(4):451-5. PubMed ID: 11903430 [Abstract] [Full Text] [Related]
75. Stabilities of quantitative plasma culture for human immunodeficiency virus, RNA, and p24 antigen from samples collected in VACUTAINER CPT and standard VACUTAINER tubes. Mole L, Margolis D, Carroll R, Todd J, Holodniy M. J Clin Microbiol; 1994 Sep 26; 32(9):2212-5. PubMed ID: 7814549 [Abstract] [Full Text] [Related]
76. Glucose is stable during prolonged storage in un-centrifuged Greiner tubes with liquid citrate buffer, but not in serum and NaF/KOx tubes. Juricic G, Bakliza A, Saracevic A, Kopcinovic LM, Dobrijevic S, Drmic S, Simundic AM. Clin Chem Lab Med; 2016 Mar 26; 54(3):411-8. PubMed ID: 26695197 [Abstract] [Full Text] [Related]
77. Impact of recentrifugation of blood collection tubes on chemistry and immunochemistry analytes after 24 and 72 hours of refrigerated storage on the Roche Cobas 8000 platform. Bowen RAR, Esguerra V, Walker M, Cheng P, Nguyen T. Clin Chim Acta; 2022 Jun 01; 531():342-351. PubMed ID: 35513039 [Abstract] [Full Text] [Related]
79. Studies on the use of BD Vacutainer® SST II™ and RST™ in general practice: investigation of artefactual hyperkalaemia. Huyghe T, Buntinx F, Bruyninckx R, Besard V, Vunckx J, Church S, Byron K, Rosa R, Blanckaert N. Ann Clin Biochem; 2014 Jan 01; 51(Pt 1):30-7. PubMed ID: 23897107 [Abstract] [Full Text] [Related]
80. Use of the BD vacutainer rapid serum tube reduces false-positive results for selected beckman coulter Unicel DxI immunoassays. Strathmann FG, Ka MM, Rainey PM, Baird GS. Am J Clin Pathol; 2011 Aug 01; 136(2):325-9. PubMed ID: 21757607 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]