21. In vitro fluid dynamic characteristics of the Medtronic-Hall pivoting disc heart valve prosthesis. Yoganathan AP, Stevenson DM, Williams FP, Woo YR, Franch RH, Harrison EC. Scand J Thorac Cardiovasc Surg; 1982; 16(3):235-43. PubMed ID: 6221405 [Abstract] [Full Text] [Related]
25. Pressure drop and velocity fields at four mechanical heart valve prostheses: Björk-Shiley Standard, Björk-Shiley Concave-Convex, Hall-Kaster and St. Jude Medical. Bruss KH, Reul H, van Gilse J, Knott E. Life Support Syst; 1983; 1(1):3-22. PubMed ID: 6678369 [No Abstract] [Full Text] [Related]
26. A database obtained from in vitro function testing of mechanical heart valves. Walker DK, Scotten LN. J Heart Valve Dis; 1994 Sep; 3(5):561-70. PubMed ID: 8000593 [Abstract] [Full Text] [Related]
27. An in-vitro technique for assessment of thrombogenicity in mechanical prosthetic cardiac valves: evaluation with a range of valve types. Martin AJ, Christy JR. J Heart Valve Dis; 2004 May; 13(3):509-20. PubMed ID: 15222300 [Abstract] [Full Text] [Related]
28. [Instantaneous blood flow velocity profiles before and after aortic valve replacement (author's transl)]. Meisner H, Hagl S, Heimisch W, Gams E, Erben R, Struck E, Schmidt-Habelmann P, Sebening F. Thoraxchir Vask Chir; 1975 Jun; 23(3):282-90. PubMed ID: 1080605 [Abstract] [Full Text] [Related]
29. Experimental evaluation of mechanical haemolysis with Starr-Edwards, Kay-Shiley and Björk-Shiley valves. Sallam IA, Shaw A, Bain WH. Scand J Thorac Cardiovasc Surg; 1976 Jun; 10(2):117-22. PubMed ID: 951582 [Abstract] [Full Text] [Related]
30. In vitro pulsatile flow measurements in the vicinity of mechanical heart valves in the mitral flow chamber. Woo YR, Yoganathan AP. Life Support Syst; 1986 Jun; 4(2):115-39. PubMed ID: 2943945 [Abstract] [Full Text] [Related]
37. Doppler hemodynamic evaluation of prosthetic (Starr-Edwards and Björk-Shiley) and bioprosthetic (Hancock and Carpentier-Edwards) cardiac valves. Williams GA, Labovitz AJ. Am J Cardiol; 1985 Aug 01; 56(4):325-32. PubMed ID: 4025173 [Abstract] [Full Text] [Related]
38. In vitro fluid dynamic characteristics of Ionescu-Shiley and Carpentier-Edwards tissue bioprostheses. Yoganathan AP, Woo YR, Williams FP, Stevenson DM, Franch RH, Harrison EC. Artif Organs; 1983 Nov 01; 7(4):459-69. PubMed ID: 6651586 [Abstract] [Full Text] [Related]
39. [Doppler echocardiography in assessing mechanical and biological heart valve prostheses]. Minardi G, Di Segni M, Boccardi L, Ferrari O, Giovannini E. G Ital Cardiol; 1988 Feb 01; 18(2):121-34. PubMed ID: 3410201 [Abstract] [Full Text] [Related]