These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


165 related items for PubMed ID: 30213111

  • 1. Display in the Wild (DIW): An Adaptive Projection-Imaging System to Screen Geometry in Real Time.
    Ryu B, Bae SH.
    Sensors (Basel); 2018 Sep 12; 18(9):. PubMed ID: 30213111
    [Abstract] [Full Text] [Related]

  • 2. Real-Time Seamless Multi-Projector Displays on Deformable Surfaces.
    Ibrahim MT, Gopi M, Majumder A.
    IEEE Trans Vis Comput Graph; 2024 May 12; 30(5):2527-2537. PubMed ID: 38437087
    [Abstract] [Full Text] [Related]

  • 3. Registration techniques for using imperfect and partially calibrated devices in planar multi-projector displays.
    Bhasker E, Juang R, Majumder A.
    IEEE Trans Vis Comput Graph; 2007 May 12; 13(6):1368-75. PubMed ID: 17968086
    [Abstract] [Full Text] [Related]

  • 4. Homography based identification for automatic and robust calibration of projection integral imaging displays.
    Jorissen L, Jackin BJ, Oi R, Wakunami K, Okui M, Ichihashi Y, Lafruit G, Yamamoto K, Bekaert P.
    Appl Opt; 2019 Feb 01; 58(4):1200-1209. PubMed ID: 30874172
    [Abstract] [Full Text] [Related]

  • 5. Autocalibrating Tiled Projectors on Piecewise Smooth Vertically Extruded Surfaces.
    Sajadi B, Majumder A.
    IEEE Trans Vis Comput Graph; 2011 Sep 01; 17(9):1209-22. PubMed ID: 21301026
    [Abstract] [Full Text] [Related]

  • 6. Projected image correction technology research on autonomous-perception anisotropic surfaces.
    Yang F, Han C, Bai BX, Zhang C.
    Appl Opt; 2018 Jan 10; 57(2):283-294. PubMed ID: 29328177
    [Abstract] [Full Text] [Related]

  • 7. Calibration method of multi-projector display system with extra-large FOV and quantitative registration accuracy analysis.
    Hou Y, Su X, Chen W, Zhao W.
    Opt Express; 2021 Oct 25; 29(22):36704-36719. PubMed ID: 34809075
    [Abstract] [Full Text] [Related]

  • 8. Automated Geometric Registration for Multi-Projector Displays on Arbitrary 3D Shapes Using Uncalibrated Devices.
    Tehrani MA, Gopi M, Majumder A.
    IEEE Trans Vis Comput Graph; 2021 Apr 25; 27(4):2265-2279. PubMed ID: 31689195
    [Abstract] [Full Text] [Related]

  • 9. Autocalibration of a projector-camera system.
    Okatani T, Deguchi K.
    IEEE Trans Pattern Anal Mach Intell; 2005 Dec 25; 27(12):1845-55. PubMed ID: 16355654
    [Abstract] [Full Text] [Related]

  • 10. Out-of-Focus Projector Calibration Method with Distortion Correction on the Projection Plane in the Structured Light Three-Dimensional Measurement System.
    Zhang J, Zhang Y, Chen B.
    Sensors (Basel); 2017 Dec 20; 17(12):. PubMed ID: 29261172
    [Abstract] [Full Text] [Related]

  • 11. Autocalibration of multiprojector CAVE-like immersive environments.
    Sajadi B, Majumder A.
    IEEE Trans Vis Comput Graph; 2012 Mar 20; 18(3):381-93. PubMed ID: 22025748
    [Abstract] [Full Text] [Related]

  • 12. Iterative calibration method for measurement system having lens distortions in fringe projection profilometry.
    Xing S, Guo H.
    Opt Express; 2020 Jan 20; 28(2):1177-1196. PubMed ID: 32121833
    [Abstract] [Full Text] [Related]

  • 13. Defocus and geometric distortion correction for projected images on a curved surface.
    Park J, Lee BU.
    Appl Opt; 2016 Feb 01; 55(4):896-902. PubMed ID: 26836098
    [Abstract] [Full Text] [Related]

  • 14. Markerless view-independent registration of multiple distorted projectors on extruded surfaces using an uncalibrated camera.
    Sajadi B, Majumder A.
    IEEE Trans Vis Comput Graph; 2009 Feb 01; 15(6):1307-16. PubMed ID: 19834203
    [Abstract] [Full Text] [Related]

  • 15. Correcting projector lens distortion in real time with a scale-offset model for structured light illumination.
    Zhang G, Xu B, Lau DL, Zhu C, Liu K.
    Opt Express; 2022 Jul 04; 30(14):24507-24522. PubMed ID: 36237004
    [Abstract] [Full Text] [Related]

  • 16. Suppression of projector distortion in phase-measuring profilometry by projecting adaptive fringe patterns.
    Peng J, Liu X, Deng D, Guo H, Cai Z, Peng X.
    Opt Express; 2016 Sep 19; 24(19):21846-60. PubMed ID: 27661920
    [Abstract] [Full Text] [Related]

  • 17. Animated Stickies: Fast Video Projection Mapping onto a Markerless Plane through a Direct Closed-Loop Alignment.
    Kagami S, Hashimoto K.
    IEEE Trans Vis Comput Graph; 2019 Nov 19; 25(11):3094-3104. PubMed ID: 31484122
    [Abstract] [Full Text] [Related]

  • 18. Directionally Decomposing Structured Light for Projector Calibration.
    Sugimoto M, Iwai D, Ishida K, Punpongsanon P, Sato K.
    IEEE Trans Vis Comput Graph; 2021 Nov 19; 27(11):4161-4170. PubMed ID: 34449387
    [Abstract] [Full Text] [Related]

  • 19. Automatic Camera Calibration Using Active Displays of a Virtual Pattern.
    Tan L, Wang Y, Yu H, Zhu J.
    Sensors (Basel); 2017 Mar 27; 17(4):. PubMed ID: 28346366
    [Abstract] [Full Text] [Related]

  • 20. Projector placement planning for high quality visualizations on real-world colored objects.
    Law AJ, Aliaga DG, Majumder A.
    IEEE Trans Vis Comput Graph; 2010 Mar 27; 16(6):1633-41. PubMed ID: 20975206
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 9.