These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
163 related items for PubMed ID: 30439354
21. Comparison of Improvacuter™ tubes with BD Vacutainer™ tubes for various hormones in the aspects of stability and influence of gel separators. Zungun C, Yılmaz FM, Boru EG, Topcuoglu C. Clin Chem Lab Med; 2015 Feb; 53(2):231-8. PubMed ID: 25153600 [Abstract] [Full Text] [Related]
22. Evaluation of BD Vacutainer SST™ II Plus tubes for common tumor marker tests by Roche Diagnostics Modular E 170 analyzer. Li Z, Feng Z, Yan C, Yan R. J Clin Lab Anal; 2010 Feb; 24(6):418-21. PubMed ID: 21089174 [Abstract] [Full Text] [Related]
23. Determination of Drugs in Plasma Samples by High-Performance Liquid Chromatography-Tandem Mass Spectrometry for Therapeutic Drug Monitoring of Schizophrenic Patients. Domingues DS, Pinto MA, de Souza ID, Hallak JE, Crippa JA, Queiroz ME. J Anal Toxicol; 2016 Feb; 40(1):28-36. PubMed ID: 26333987 [Abstract] [Full Text] [Related]
24. Suitability of collection tubes with separator gels for collecting and storing blood samples for therapeutic drug monitoring (TDM). Karppi J, Akerman KK, Parviainen M. Clin Chem Lab Med; 2000 Apr; 38(4):313-20. PubMed ID: 10928651 [Abstract] [Full Text] [Related]
25. Switching from serum to plasma: Implementation of BD Vacutainer® Barricor™ Plasma Blood Collection Tubes improves sample quality and laboratory turnaround time. Ramakers C, Meyer B, Yang W, Plokhoy E, Xiong Y, Church S, Kaushik N. Pract Lab Med; 2020 Jan; 18():e00149. PubMed ID: 31909146 [Abstract] [Full Text] [Related]
26. Evaluation of serum and rapid serum separator collection tubes for therapeutic drug assays. Garza KY, Carter J, Mercer A, Jarrar P, Martin J, Daughtry S, Mahomes A, Knezevic CE. Clin Biochem; 2023 May; 115():81-85. PubMed ID: 36027943 [Abstract] [Full Text] [Related]
27. Analysis of drugs in plasma samples from schizophrenic patients by column-switching liquid chromatography-tandem mass spectrometry with organic-inorganic hybrid cyanopropyl monolithic column. Domingues DS, Souza ID, Queiroz ME. J Chromatogr B Analyt Technol Biomed Life Sci; 2015 Jul 01; 993-994():26-35. PubMed ID: 25984963 [Abstract] [Full Text] [Related]
28. Evaluation of BD Vacutainer SST™ II plus tubes for special proteins testing. Li Z, Yan C, Yan R, Zheng X, Feng Z. J Clin Lab Anal; 2011 Jul 01; 25(3):203-6. PubMed ID: 21567469 [Abstract] [Full Text] [Related]
29. Plasma glucose measurement in diabetes: impact and implications of variations in sample collection procedures with a focus on the first hour after sample collection. Chan H, Lunt H, Thompson H, Heenan HF, Frampton CM, Florkowski CM. Clin Chem Lab Med; 2014 Jul 01; 52(7):1061-8. PubMed ID: 24706432 [Abstract] [Full Text] [Related]
30. UPLC-MS/MS determination in blood of a mixed-drug fatal intoxication: a case report. Proença P, Franco JM, Mustra C, Monteiro C, Costa J, Corte-Real F, Vieira DN. Forensic Sci Int; 2013 Apr 10; 227(1-3):85-9. PubMed ID: 23159339 [Abstract] [Full Text] [Related]
31. Comparison of conventional liquid chromatography-tandem mass spectrometry versus microflow liquid chromatography-tandem mass spectrometry within the framework of full method validation for simultaneous quantification of 40 antidepressants and neuroleptics in whole blood. Steuer AE, Poetzsch M, Koenig M, Tingelhoff E, Staeheli SN, Roemmelt AT, Kraemer T. J Chromatogr A; 2015 Feb 13; 1381():87-100. PubMed ID: 25596763 [Abstract] [Full Text] [Related]
32. Stability of Direct Oral Anticoagulants and Antiarrhythmic Drugs in Serum Collected in Standard (Nongel) Serum Tubes Versus Tubes Containing Gel Separators. Hegstad S, Fuskevåg OM, Amundsen S, Gule M, Spigset O, Helland A. Ther Drug Monit; 2022 Apr 01; 44(2):328-334. PubMed ID: 34310545 [Abstract] [Full Text] [Related]
33. Time-dependent absorption of therapeutic drugs by the gel of the Greiner Vacuette blood collection tube. Dasgupta A, Yared MA, Wells A. Ther Drug Monit; 2000 Aug 01; 22(4):427-31. PubMed ID: 10942183 [Abstract] [Full Text] [Related]
34. Improved Sample Quality and Decreased Turnaround Time When Using Plasma Blood Collection Tubes with a Mechanical Separator in a Large University Hospital. Hétu PO, Hobeila S, Larivière F, Bélanger MC. J Appl Lab Med; 2021 Mar 01; 6(2):409-420. PubMed ID: 32989467 [Abstract] [Full Text] [Related]
35. Screening analysis for medicinal drugs and drugs of abuse in whole blood using ultra-performance liquid chromatography time-of-flight mass spectrometry (UPLC-TOF-MS)--toxicological findings in cases of alleged sexual assault. Birkler RI, Telving R, Ingemann-Hansen O, Charles AV, Johannsen M, Andreasen MF. Forensic Sci Int; 2012 Oct 10; 222(1-3):154-61. PubMed ID: 22770621 [Abstract] [Full Text] [Related]
38. Stability of therapeutic drug measurement in specimens collected in VACUTAINER plastic blood-collection tubes. Dasgupta A, Blackwell W, Bard D. Ther Drug Monit; 1996 Jun 10; 18(3):306-9. PubMed ID: 8738774 [Abstract] [Full Text] [Related]
39. Stability of Antidepressants and Antipsychotics in Gel Separator Tubes. Berg JA, Schjøtt J, Carstensen K, Fossan KO, Skrede S, Bjånes TK, Serkland TT, Riedel B. Ther Drug Monit; 2019 Apr 10; 41(2):249-250. PubMed ID: 30883518 [No Abstract] [Full Text] [Related]
40. Stability of ribavirin concentrations depending on the type of blood collection tube and preanalytical conditions. Marquet P, Sauvage FL, Loustaud-Ratti V, Babany G, Rousseau A, Lachâtre G. Ther Drug Monit; 2010 Apr 10; 32(2):237-41. PubMed ID: 20216114 [Abstract] [Full Text] [Related] Page: [Previous] [Next] [New Search]