These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
201 related items for PubMed ID: 30794637
1. Performance of the BD-FACS Presto for CD4 count and hemoglobin measurement in a district hospital and rural laboratory in Ghana. Moran Z, Sacks JA, Frimpong FK, Frimpong AB, Ben Amor Y. PLoS One; 2019; 14(2):e0212684. PubMed ID: 30794637 [Abstract] [Full Text] [Related]
2. Performance evaluation of BD FACSPresto™ point of care CD4 analyzer to enumerate CD4 counts for monitoring HIV infected individuals in Nigeria. Negedu-Momoh OR, Jegede FE, Yakubu A, Balogun O, Abdullahi M, Badru T, Oladele EA, Agbakwuru C, Khamofu H, Torpey K. PLoS One; 2017; 12(5):e0178037. PubMed ID: 28542359 [Abstract] [Full Text] [Related]
3. Performance of the BD FACSPresto near to patient analyzer in comparison with representative conventional CD4 instruments in Cameroon. Sagnia B, Mbakop Ghomsi F, Gutierrez A, Sosso S, Kamgaing R, Nanfack AJ, Nji N, Ambada G, Lissom A, Tchouangueu TF, Ngu Ndengkoh L, Domkam I, Nchinda G, Ndjolo A. AIDS Res Ther; 2020 Aug 17; 17(1):53. PubMed ID: 32799909 [Abstract] [Full Text] [Related]
4. The performance of BD FACSPresto™ for CD4 T-cell count, CD4% and hemoglobin concentration test in Ethiopia. Gebremicael G, Belay Y, Girma F, Abreha Y, Gebreegziabxier A, Tesfaye S, Messele Z, Assefa Y, Bellete B, Kassa D, Vojnov L. PLoS One; 2017 Aug 17; 12(4):e0176323. PubMed ID: 28448581 [Abstract] [Full Text] [Related]
5. The BD FACSPresto Point of Care CD4 Test Accurately Enumerates CD4+ T Cell Counts. Bwana P, Vojnov L, Adhiambo M, Akinyi C, Mwende J, Prescott M, Mwau M. PLoS One; 2015 Aug 17; 10(12):e0145586. PubMed ID: 26720601 [Abstract] [Full Text] [Related]
6. Validation of the BD FACSPresto system for the measurement of CD4 T-lymphocytes and hemoglobin concentration in HIV-negative and HIV-positive subjects. Lu X, Sun H, Li H, Xia W, Wu H, Chen D, Tan M, Yu S, Zhang T, Sheng H, Zhu Z. Sci Rep; 2020 Nov 11; 10(1):19605. PubMed ID: 33177659 [Abstract] [Full Text] [Related]
7. Performance of FACSPresto Point-of-Care Instrument for CD4-T Cell Enumeration in Human Immunodeficiency Virus (HIV)-Infected Patients Attending Care and Treatment Clinics in Belgium and Tanzania. Daneau G, Aboud S, Prat I, Urassa W, Kestens L. PLoS One; 2017 Nov 11; 12(1):e0170248. PubMed ID: 28129324 [Abstract] [Full Text] [Related]
8. Evaluation of the FACSPresto, a New Point of Care Device for the Enumeration of CD4% and Absolute CD4+ T Cell Counts in HIV Infection. Makadzange AT, Bogezi C, Boyd K, Gumbo A, Mukura D, Matubu A, Ndhlovu CE. PLoS One; 2016 Nov 11; 11(7):e0157546. PubMed ID: 27388763 [Abstract] [Full Text] [Related]
9. Using BD Vacutainer CD4 Stabilization Tubes for Absolute Cluster of Differentiation Type 4 Cell Count Measurement on BD FacsCount and Partec Cyflow Cytometers: A Method Comparison Study from Zimbabwe. Vogt F, Van den Bergh R, Bernasconi A, Moyo B, Havazvidi L, Bastard M, Flevaud L, Taziwa F, Makondo E, Mtapuri-Zinyowera S. PLoS One; 2015 Nov 11; 10(8):e0136537. PubMed ID: 26295802 [Abstract] [Full Text] [Related]
10. CD4 Lymphocyte Enumeration and Hemoglobin Assessment Aid for Priority Decisions: A Multisite Evaluation of the BD FACSPresto™ System. Thakar M, Angira F, Pattanapanyasat K, Wu AHB, O'Gorman M, Zeng H, Qu C, Mahajan B, Sukapirom K, Chen D, Hao Y, Gong Y, Indig MA, Graminske S, Orta D, d'Empaire N, Lu B, Omana-Zapata I, Zeh C. Open AIDS J; 2017 Nov 11; 11():76-90. PubMed ID: 29290885 [Abstract] [Full Text] [Related]
11. Assessment of two POC technologies for CD4 count in Morocco. Elharti E, Abbadi H, Bensghir R, Marhoum El Filali K, Elmrabet H, Oumzil H. AIDS Res Ther; 2020 Jun 10; 17(1):31. PubMed ID: 32522235 [Abstract] [Full Text] [Related]
12. Clinical Evaluation of the BD FACSPresto™ Near-Patient CD4 Counter in Kenya. Angira F, Akoth B, Omolo P, Opollo V, Bornheimer S, Judge K, Tilahun H, Lu B, Omana-Zapata I, Zeh C. PLoS One; 2016 Jun 10; 11(8):e0157939. PubMed ID: 27483008 [Abstract] [Full Text] [Related]
13. Accurate and reproducible enumeration of CD4 T cell counts and Hemoglobin levels using a point of care system: Comparison with conventional laboratory based testing systems in a clinical reference laboratory in Cameroon. Sagnia B, Mbakop Ghomsi F, Moudourou S, Gutierez A, Tchadji J, Sosso SM, Ndjolo A, Colizzi V. PLoS One; 2024 Jun 10; 19(3):e0297790. PubMed ID: 38507344 [Abstract] [Full Text] [Related]
14. Field Performance of PIMA Point-of-Care Machine for CD4 Enumeration Under a Mobile HIV Counseling and Testing Program in Remote Fishing Communities of Lake Victoria, Uganda. Namuniina A, Lutwama F, Biribawa VM, Kizza D, Kabuubi BR, Kitandwe PK, Mpendo J, Nanvubya A, Ssempiira J, Nalutaaya A, Ssetaala A, Welsh S, Price MA, Kiwanuka N, Bagaya BS. AIDS Res Hum Retroviruses; 2019 Apr 10; 35(4):382-387. PubMed ID: 30560683 [Abstract] [Full Text] [Related]
15. Performance Evaluation of BD FACSPrestoTM Near-Patient CD4 Counter for Monitoring Antiretroviral Therapy in HIV-Infected Individuals in Primary Healthcare Clinics in Thailand. Sukapirom K, Matchua S, Thepthai C, Srimark N, Khowawisetsut L, Pattanapanyasat K. Diagnostics (Basel); 2022 Feb 02; 12(2):. PubMed ID: 35204474 [Abstract] [Full Text] [Related]
16. Laboratory and field evaluation of the Partec CyFlow miniPOC for absolute and relative CD4 T-cell enumeration. Wade D, Diaw PA, Daneau G, Diallo AA, Mboup S, Dieye TN, Kestens L. PLoS One; 2015 Feb 02; 10(2):e0116663. PubMed ID: 25688553 [Abstract] [Full Text] [Related]
18. Performance evaluation of the Pima™ point-of-care CD4 analyser using capillary blood sampling in field tests in South Africa. Glencross DK, Coetzee LM, Faal M, Masango M, Stevens WS, Venter WF, Osih R. J Int AIDS Soc; 2012 Jan 30; 15(1):3. PubMed ID: 22284546 [Abstract] [Full Text] [Related]
20. Multisite evaluation of point of care CD4 testing in Papua New Guinea. Malagun M, Nano G, Chevallier C, Opina R, Sawiya G, Kivavia J, Kalinoe A, Nathaniel K, Kaminiel O, Millan J, Carmone A, Dini M, Palou T, Topma K, Lavu E, Markby J. PLoS One; 2014 Jan 30; 9(11):e112173. PubMed ID: 25426710 [Abstract] [Full Text] [Related] Page: [Next] [New Search]