These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


92 related items for PubMed ID: 3096245

  • 1. [Doppler technics in the study of prosthetic valves].
    Veyrat C, Gourtchiglouian C, Bas S, Abitbol G, Gramage JY, Kalmanson D.
    Arch Mal Coeur Vaiss; 1986 Jul; 79(8):1195-204. PubMed ID: 3096245
    [Abstract] [Full Text] [Related]

  • 2. [Contribution of Doppler echocardiography to the evaluation and monitoring of normal and pathologic mitral valve prostheses].
    Habib G, Bénichou M, Bonnet JL, Gisbert MP, Cornen A, Djiane P, Bory M, Serradimigni A.
    Arch Mal Coeur Vaiss; 1990 Apr; 83(4):469-77. PubMed ID: 2111667
    [Abstract] [Full Text] [Related]

  • 3. [Contribution of Doppler echocardiography in the evaluation of normal and pathologic aortic valve prosthesis].
    Habib G, Bénichou M, Gisbert MP, Bonnet JL, Scemama J, Djiane P, Bory M, Serradigmigni A.
    Arch Mal Coeur Vaiss; 1990 Jun; 83(7):937-45. PubMed ID: 2114853
    [Abstract] [Full Text] [Related]

  • 4. [Doppler echocardiography in assessing mechanical and biological heart valve prostheses].
    Minardi G, Di Segni M, Boccardi L, Ferrari O, Giovannini E.
    G Ital Cardiol; 1988 Feb; 18(2):121-34. PubMed ID: 3410201
    [Abstract] [Full Text] [Related]

  • 5. [Doppler study of porcine bioprosthesis at the mitral site].
    Montemurro D, Ronzani G, Bobbio M, Orzan F, Brusca A.
    G Ital Cardiol; 1987 Apr; 17(4):311-7. PubMed ID: 3653588
    [Abstract] [Full Text] [Related]

  • 6. [A Doppler echocardiographic study of normal and dysfunctioning Carpentier-Edwards bioprostheses].
    Bonaduce D, Breglio R, Conforti G, Montemurro MV, Petretta M, Covino E, Morgano G, Bianchi V.
    G Ital Cardiol; 1990 Jan; 20(1):50-7. PubMed ID: 2328859
    [Abstract] [Full Text] [Related]

  • 7. [Doppler echocardiographic evaluation of aortic valve prosthesis. Analysis of the reproducibility of pressure gradients and surface measurements].
    Berdah J, Baubion N, Massougbodji M, Montgermont P, Atal L, Le Pailleur C, Vacheron A.
    Arch Mal Coeur Vaiss; 1991 Jan; 84(1):27-32. PubMed ID: 2012482
    [Abstract] [Full Text] [Related]

  • 8. [Intracardiac flow dynamic alterations with a prosthetic mitral valve studied by pulsed Doppler technique].
    Kitabatake A, Tanouchi J, Asao M, Mishima M, Ishihara K, Masuyama T, Inoue M, Abe H, Matsuo H, Morita H.
    J Cardiogr; 1985 Jun; 15(2):469-82. PubMed ID: 4093627
    [Abstract] [Full Text] [Related]

  • 9. [Continuous wave Doppler assessment of prosthetic valves in the mitral position: comparison of the St. Jude medical mechanical valve and the porcine xenograft valve].
    Kisanuki A, Tei C, Arikawa K, Natsugoe K, Otsuji Y, Kawazoe Y, Tanaka H, Morishita Y, Maruko M, Taira A.
    J Cardiogr; 1985 Dec; 15(4):1119-27. PubMed ID: 3841894
    [Abstract] [Full Text] [Related]

  • 10. [Doppler evaluation of porcine mitral valve dysfunction].
    Nakamura K, Matsumura K, Satomi G, Sakai K, Ishizuka N, Mori K, Shiina T, Kikuchi N, Hirosawa K, Takao A.
    J Cardiogr; 1986 Dec; 16(4):929-39. PubMed ID: 3429909
    [Abstract] [Full Text] [Related]

  • 11. [Late complications of valve replacement: the benefits of non-invasive assessment].
    Akasaka T, Yoshikawa J, Yoshida K, Shakudo M, Okumachi F, Koizumi K, Shiratori K, Takao S, Jyo Y, Fukaya T.
    J Cardiol; 1988 Mar; 18(1):163-78. PubMed ID: 3065474
    [Abstract] [Full Text] [Related]

  • 12. [Doppler echocardiography in dysfunctions of valvular prostheses: diagnostic and quantitative significance. Apropos of 20 cases].
    Laflèche A, Verges B, Malergue MC.
    Arch Mal Coeur Vaiss; 1987 May; 80(5):598-608. PubMed ID: 3113378
    [Abstract] [Full Text] [Related]

  • 13. [Doppler echocardiography in the examination of normally functioning artificial mitral and aortic valves].
    Forster T, Varga A, Borthaiser A, Kocsis Z, Varga L, Kardos A, Csanády M.
    Orv Hetil; 1991 Nov 24; 132(47):2591-7. PubMed ID: 1956682
    [Abstract] [Full Text] [Related]

  • 14. [Normal echo-Doppler values in Duromedics valvular prostheses].
    Gioia G, Rutsch W.
    G Ital Cardiol; 1988 Mar 24; 18(3):213-7. PubMed ID: 3169470
    [Abstract] [Full Text] [Related]

  • 15. [Doppler-echocardiographic determination of the degree of severity of mitral stenosis].
    Dennig K, Rudolph W.
    Herz; 1984 Aug 24; 9(4):222-30. PubMed ID: 6479832
    [Abstract] [Full Text] [Related]

  • 16. [The Duromedics mitral valve mechanical prosthesis: evaluation by means of transesophageal echocardiography].
    Desideri A, Dreysse S, Schartl M.
    G Ital Cardiol; 1989 Aug 24; 19(8):680-5. PubMed ID: 2806797
    [Abstract] [Full Text] [Related]

  • 17. [Doppler sonographic determination of the degree of severity of mitral valve stenoses].
    Niehues B, Schwarzenbart E, Neufeind A, Hilger HH.
    Z Kardiol; 1985 Jan 24; 74(1):23-31. PubMed ID: 3976260
    [Abstract] [Full Text] [Related]

  • 18. [Study using non-invasive methods in prostheses of bovine pericardium in aortic position manufactured at the Ignacio Chávez National Institute of Cardiology].
    Galván Infante PB, Esquivel-Avila JG, Canepa Campos F, Fernández de la Reguera G, Barragán García R, Friedland C, Varela Sadurní J.
    Arch Inst Cardiol Mex; 1987 Jan 24; 57(1):19-24. PubMed ID: 2952084
    [Abstract] [Full Text] [Related]

  • 19. [Non-invasive estimation of transmitral pressure gradient and mitral valve area in mitral stenosis by an ultrasonic pulsed Doppler technique].
    Asao M, Kitabatake A, Inoue M, Tanouchi J, Morita T, Masuyama T, Mishima M, Shimazu T, Ishihara K, Fujii K.
    J Cardiogr; 1984 Jun 24; 14(1):149-61. PubMed ID: 6240509
    [Abstract] [Full Text] [Related]

  • 20. [Echo-Doppler evaluation of normal Starr-Edwards prostheses in mitral and aortic position].
    Lefebvre E, Isorni C, Rey JL, Lesbre JP.
    Arch Mal Coeur Vaiss; 1987 Jun 24; 80(7):1105-14. PubMed ID: 3118834
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 5.