These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
119 related items for PubMed ID: 31011608
1. Comparison between Roche Integra 400 plus and Abbott Architect ci8200 in Alanine aminotransferase assay. Lamrabat S, Lyagoubi A, Bouayadi O, Elmalki J, Elkouche K, Bensalah M, Choukri M. Pract Lab Med; 2019 May; 15():e00121. PubMed ID: 31011608 [Abstract] [Full Text] [Related]
2. [Comparative study of the serum measurement of PTH on Roche Cobas e411® versus the Abbott Architect ci8200®]. Bensalah M, Bouayadi O, Rahmani N, Lyagoubi A, Lamrabat S, Choukri M. Ann Biol Clin (Paris); 2018 Jan 01; 76(1):61-67. PubMed ID: 29243659 [Abstract] [Full Text] [Related]
3. Comparison of the Siemens Atellica BRAHMS and the Abbott Architect BRAHMS Procalcitonin Assays. Walker C, Shuster A, Weber C, Gebhardt K, Scheidegger M, Swartzwelder J, Williams J, Li J. Ann Clin Lab Sci; 2021 Mar 01; 51(2):241-244. PubMed ID: 33941564 [Abstract] [Full Text] [Related]
4. Evaluation of analytical methods and workflow performance of the Architect ci8200 integrated serum/plasma analyzer system. Hubl W, Zogbaum M, Boyd JC, Savory J, Schubert M, Meyer D, Demant T. Clin Chim Acta; 2005 Jul 01; 357(1):43-54. PubMed ID: 15963793 [Abstract] [Full Text] [Related]
5. A comparison between two different automated total 25-hydroxyvitamin D immunoassay methods using liquid chromatography-tandem mass spectrometry. Kocak FE, Ozturk B, Isiklar OO, Genc O, Unlu A, Altuntas I. Biochem Med (Zagreb); 2015 Jul 01; 25(3):430-8. PubMed ID: 26526462 [Abstract] [Full Text] [Related]
6. Measurement Differences Between Two Immunoassay Systems for LH and FSH: A Comparison of Roche Cobas e601 vs. Abbott Architect i2000sr. Yin L, Tang Y, Chen X, Sun Y. Clin Lab; 2018 Mar 01; 64(3):295-301. PubMed ID: 29739096 [Abstract] [Full Text] [Related]
7. Comparison of Three Immunoassays Systems for Determining Serum Estradiol. Zhang H, Huang Y, Liang K. Clin Lab; 2019 Apr 01; 65(4):. PubMed ID: 30969070 [Abstract] [Full Text] [Related]
8. Comparison of Four Automated Carcinoembryonic Antigen Immunoassays: ADVIA Centaur XP, ARCHITECT I2000sr, Elecsys E170, and Unicel Dxi800. Park J, Lee S, Kim Y, Choi A, Lee H, Lim J, Kim Y, Han K, Oh EJ. Ann Lab Med; 2018 Jul 01; 38(4):355-361. PubMed ID: 29611386 [Abstract] [Full Text] [Related]
9. Assessment of Abbott Architect 25-OH vitamin D assay in different levels of vitamin D. Avci E, Demir S, Aslan D, Nar R, Şenol H. J Med Biochem; 2020 Jan 10; 39(1):100-107. PubMed ID: 32549783 [Abstract] [Full Text] [Related]
10. Evaluation of the Novel Methotrexate Architect Chemiluminescent Immunoassay: Clinical Impact on Pharmacokinetic Monitoring. Aumente MD, López-Santamaría J, Donoso-Rengifo MC, Reyes-Torres I, Montejano Hervás P. Ther Drug Monit; 2017 Oct 10; 39(5):492-498. PubMed ID: 28682926 [Abstract] [Full Text] [Related]
11. Multisite analytical evaluation of the Abbott ARCHITECT cyclosporine assay. Wallemacq P, Maine GT, Berg K, Rosiere T, Marquet P, Aimo G, Mengozzi G, Young J, Wonigeit K, Kretschmer R, Wermuth B, Schmid RW. Ther Drug Monit; 2010 Apr 10; 32(2):145-51. PubMed ID: 20216110 [Abstract] [Full Text] [Related]
12. Verification of the harmonization of human epididymis protein 4 assays. Ferraro S, Borille S, Carnevale A, Frusciante E, Bassani N, Panteghini M. Clin Chem Lab Med; 2016 Oct 01; 54(10):1635-43. PubMed ID: 27028735 [Abstract] [Full Text] [Related]
13. Evaluation of immunoturbidimetric specific protein methods using the Architect ci8200: comparison with immunonephelometry. Denham E, Mohn B, Tucker L, Lun A, Cleave P, Boswell DR. Ann Clin Biochem; 2007 Nov 01; 44(Pt 6):529-36. PubMed ID: 17961307 [Abstract] [Full Text] [Related]
14. Can Measurement of Progesterone, Estradiol, and Prolactin by Immunoassay be Interchanged? A Comparison of the Roche Cobas e601 vs. Abbott Architect i2000sr. Yin L, Chen X, Tang Y, Sun Y. Clin Lab; 2017 Mar 01; 63(3):569-577. PubMed ID: 28271677 [Abstract] [Full Text] [Related]
15. Comparison of automated methods for measurement of 25-hydroxyvitamin D. Martins-Costa P, Martins H, Bravo F, Cruz M, Reis J, Oliveira JC. Clin Lab; 2013 Mar 01; 59(7-8):885-91. PubMed ID: 24133920 [Abstract] [Full Text] [Related]
16. Comparison of two ferritin assay platforms to assess their level of agreement in measuring serum and plasma ferritin levels in patients with chronic kidney disease. Majoni SW, Nelson J, Graham J, Abeyaratne A, Fernandes DK, Cherian S, Rathnayake G, Ashford J, Hocking L, Cain H, McFarlane R, Lawton PD, Barzi F, Taylor S, Cass A. BMC Nephrol; 2023 Jun 30; 24(1):198. PubMed ID: 37391713 [Abstract] [Full Text] [Related]
17. Evaluation of the new restandardized Abbott Architect 25-OH Vitamin D assay in vitamin D-insufficient and vitamin D-supplemented individuals. Annema W, Nowak A, von Eckardstein A, Saleh L. J Clin Lab Anal; 2018 May 30; 32(4):e22328. PubMed ID: 28926129 [Abstract] [Full Text] [Related]
18. Analytical performance characteristics of the Abbott Architect i2000 Tacrolimus assay; comparisons with liquid chromatography-tandem mass spectrometry (LC-MS/MS) and Abbott IMx methods. De BK, Jimenez E, De S, Sawyer JC, McMillin GA. Clin Chim Acta; 2009 Dec 30; 410(1-2):25-30. PubMed ID: 19751714 [Abstract] [Full Text] [Related]
19. Comparison of the novel ARCHITECT procalcitonin assay with established procalcitonin assay systems. Soh A, Binder L, Clough M, Hernandez MH, Lefèvre G, Mostert K, Nguyen TB, Otte KM, Portakal O, Sandri MS, Yen JL, Huang J, Beshiri A. Pract Lab Med; 2018 Nov 30; 12():e00110. PubMed ID: 30519621 [Abstract] [Full Text] [Related]
20. Comparison of four routinely used vitamin D automated immunoassays. Windrichova J, Broz P, Fuchsova R, Topolcan O, Pecen L, Mayer O, Kucera R. J Med Biochem; 2021 Jun 05; 40(3):277-285. PubMed ID: 34177372 [Abstract] [Full Text] [Related] Page: [Next] [New Search]