These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


140 related items for PubMed ID: 3133003

  • 1. The applicability of evacuated serological tubes for the collection of breath for isotopic analysis of CO2 by isotope ratio mass spectrometry.
    Milne E, McGaw BA.
    Biomed Environ Mass Spectrom; 1988 May 01; 15(9):467-72. PubMed ID: 3133003
    [Abstract] [Full Text] [Related]

  • 2. Rapid, automated analysis of 13C and 18O of CO2 in gas samples by continuous-flow, isotope ratio mass spectrometry.
    Prosser SJ, Brookes ST, Linton A, Preston T.
    Biol Mass Spectrom; 1991 Nov 01; 20(11):724-30. PubMed ID: 1799584
    [Abstract] [Full Text] [Related]

  • 3. [Sensitivity and precision of the 13C-breath test].
    Suehiro M, Iio M, Morikawa J.
    Radioisotopes; 1982 Jun 01; 31(6):285-9. PubMed ID: 6817389
    [Abstract] [Full Text] [Related]

  • 4. A simplified technique for collecting breath CO2 for isotope ratio mass spectrometry.
    Schoeller DA, Klein PD.
    Biomed Mass Spectrom; 1978 Jan 01; 5(1):29-31. PubMed ID: 623890
    [Abstract] [Full Text] [Related]

  • 5. Automated measurement of 13C enrichment in carbon dioxide derived from submicromole quantities of L-(1-13C)-leucine.
    Scrimgeour CM, Smith K, Rennie MJ.
    Biomed Environ Mass Spectrom; 1988 Apr 01; 15(7):369-74. PubMed ID: 3134071
    [Abstract] [Full Text] [Related]

  • 6. Automated measurement of the concentration and 13C enrichment of carbon dioxide in breath and blood samples using the Finnigan MAT Breath Gas Analysis System.
    Scrimgeour CM, Rennie MJ.
    Biomed Environ Mass Spectrom; 1988 Apr 01; 15(7):365-7. PubMed ID: 3134070
    [Abstract] [Full Text] [Related]

  • 7. A microprocessor controlled mass spectrometer for the fully automated purification and isotopic analysis of breath carbon dioxide.
    Schoeller DA, Klein PD.
    Biomed Mass Spectrom; 1979 Aug 01; 6(8):350-5. PubMed ID: 497361
    [Abstract] [Full Text] [Related]

  • 8. Can we use the CO2 concentrations determined by continuous-flow isotope ratio mass spectrometry from small samples for the Keeling plot approach?
    Joos O, Saurer M, Heim A, Hagedorn F, Schmidt MW, Siegwolf RT.
    Rapid Commun Mass Spectrom; 2008 Dec 01; 22(24):4029-34. PubMed ID: 19009520
    [Abstract] [Full Text] [Related]

  • 9. Extraction of CO2 from air samples for isotopic analysis and limits to ultra high precision delta18O determination in CO2 gas.
    Werner RA, Rothe M, Brand WA.
    Rapid Commun Mass Spectrom; 2001 Dec 01; 15(22):2152-67. PubMed ID: 11746880
    [Abstract] [Full Text] [Related]

  • 10. Mobile, outdoor continuous-flow isotope-ratio mass spectrometer system for automated high-frequency 13C- and 18O-CO2 analysis for Keeling plot applications.
    Schnyder H, Schäufele R, Wenzel R.
    Rapid Commun Mass Spectrom; 2004 Dec 01; 18(24):3068-74. PubMed ID: 15543546
    [Abstract] [Full Text] [Related]

  • 11. Clinical diagnosis with the stable isotope 13C in CO2 breath tests: methodology and fundamental considerations.
    Schoeller DA, Schneider JF, Solomons NW, Watkins JB, Klein PD.
    J Lab Clin Med; 1977 Sep 01; 90(3):412-21. PubMed ID: 911387
    [Abstract] [Full Text] [Related]

  • 12.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 13.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 14. Nondispersive infrared spectrometry for 13CO2/12CO2-measurements: a clinically feasible analyzer for stable isotope breath tests in gastroenterology.
    Braden B, Caspary WF, Lembcke B.
    Z Gastroenterol; 1999 Jun 01; 37(6):477-81. PubMed ID: 10427653
    [Abstract] [Full Text] [Related]

  • 15.
    ; . PubMed ID:
    [No Abstract] [Full Text] [Related]

  • 16. More convenient 13C-urea breath test modifications still meet the criteria for valid diagnosis of Helicobacter pylori infection.
    Braden B, Duan LP, Caspary WF, Lembcke B.
    Z Gastroenterol; 1994 Apr 01; 32(4):198-202. PubMed ID: 8017093
    [Abstract] [Full Text] [Related]

  • 17. [New nondispersive infrared spectrometry in 13C-urea breath tests].
    Hartmann D, Schilling D, Riemann JF.
    Dtsch Med Wochenschr; 2003 Aug 01; 128(31-32):1645-8. PubMed ID: 12894391
    [Abstract] [Full Text] [Related]

  • 18. An automated system for stable isotope and concentration analyses of CO2 from small atmospheric samples.
    Schauer AJ, Lott MJ, Cook CS, Ehleringer JR.
    Rapid Commun Mass Spectrom; 2005 Aug 01; 19(3):359-62. PubMed ID: 15645505
    [Abstract] [Full Text] [Related]

  • 19. A portable automated system for trace gas sampling in the field and stable isotope analysis in the laboratory.
    Theis DE, Saurer M, Blum H, Frossard E, Siegwolf RT.
    Rapid Commun Mass Spectrom; 2004 Aug 01; 18(18):2106-12. PubMed ID: 15317047
    [Abstract] [Full Text] [Related]

  • 20. Adaptation of continuous-flow cavity ring-down spectroscopy for batch analysis of δ13C of CO2 and comparison with isotope ratio mass spectrometry.
    Berryman EM, Marshall JD, Rahn T, Cook SP, Litvak M.
    Rapid Commun Mass Spectrom; 2011 Aug 30; 25(16):2355-60. PubMed ID: 21766378
    [Abstract] [Full Text] [Related]


    Page: [Next] [New Search]
    of 7.