These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
Pubmed for Handhelds
PUBMED FOR HANDHELDS
Journal Abstract Search
133 related items for PubMed ID: 3139801
1. Titanium-coated hollow screw and reconstruction plate system for bridging of lower jaw defects: biomechanical aspects. Sutter F, Raveh J. Int J Oral Maxillofac Surg; 1988 Aug; 17(4):267-74. PubMed ID: 3139801 [Abstract] [Full Text] [Related]
2. [Mandibular reconstruction with the titanium-hollow screw-reconstruction plate system (THORP)]. Vuillemin T, Raveh J, Sutter F. Schweiz Monatsschr Zahnmed; 1990 Aug; 100(6):701-8. PubMed ID: 2377883 [Abstract] [Full Text] [Related]
3. Titanium-coated hollow screw and reconstruction plate system (THORP) in mandibular reconstruction. Hellem S, Olofsson J. J Craniomaxillofac Surg; 1988 May; 16(4):173-83. PubMed ID: 3290261 [Abstract] [Full Text] [Related]
4. [Titanium-coated hollow screw and reconstruction plate system for the bridging of jaw defects. II. Possible reconstruction variants with the THRP system]. Raveh J, Stich H, Sutter F. Chirurg; 1985 May; 56(5):337-44. PubMed ID: 3891246 [Abstract] [Full Text] [Related]
5. Use of the titanium-coated hollow screw and reconstruction plate system in bridging of lower jaw defects. Raveh J, Stich H, Sutter F, Greiner R. J Oral Maxillofac Surg; 1984 May; 42(5):281-94. PubMed ID: 6371200 [Abstract] [Full Text] [Related]
6. Mandibular reconstruction with the titanium hollow screw reconstruction plate (THORP) system: evaluation of 62 cases. Vuillemin T, Raveh J, Sutter F. Plast Reconstr Surg; 1988 Nov; 82(5):804-14. PubMed ID: 3174870 [Abstract] [Full Text] [Related]
7. Surgical procedures for reconstruction of the lower jaw using the titanium-coated hollow-screw reconstruction plate system: bridging of defects. Raveh J, Sutter F, Hellem S. Otolaryngol Clin North Am; 1987 Aug; 20(3):535-58. PubMed ID: 3684291 [Abstract] [Full Text] [Related]
8. Mandibular reconstruction with the THORP condylar prosthesis after hemimandibulectomy. Vuillemin T, Raveh J, Sutter F. J Craniomaxillofac Surg; 1989 Feb; 17(2):78-87. PubMed ID: 2921333 [Abstract] [Full Text] [Related]
9. [Bridging of the defect by the lingual approach and bone graft fixation in the mandible with the THRP (titanium-coated hollow-screw and reconstruction plate) system]. Raveh J, Sutter F. Schweiz Monatsschr Zahnmed (1984); 1984 Feb; 94(2):134-42. PubMed ID: 6367030 [No Abstract] [Full Text] [Related]
10. Does fixation method affects temporomandibular joints after mandibular advancement? Ureturk EU, Apaydin A. J Craniomaxillofac Surg; 2018 Jun; 46(6):923-931. PubMed ID: 29724535 [Abstract] [Full Text] [Related]
11. Fixation with reconstruction plates under critical conditions: the role of screw characteristics. Söderholm AL, Rahn BA, Skutnabb K, Lindqvist C. Int J Oral Maxillofac Surg; 1996 Dec; 25(6):469-73. PubMed ID: 8986552 [Abstract] [Full Text] [Related]
12. Finite element analysis of a condylar support prosthesis to replace the temporomandibular joint. Abel EW, Hilgers A, McLoughlin PM. Br J Oral Maxillofac Surg; 2015 Apr; 53(4):352-7. PubMed ID: 25703687 [Abstract] [Full Text] [Related]
13. [Titanium plasma-coated hollow screws and reconstruction plate system for the bridging of jaw defects. I. Basic principles and biomechanical properties]. Sutter F, Raveh J, Schürch H, Stich H. Chirurg; 1984 Nov; 55(11):741-8. PubMed ID: 6510088 [No Abstract] [Full Text] [Related]
14. [Advantages of the titanium plasma-coated half- and full-core reconstruction plate system (THORP) for the bridging of mandibular defects]. Raveh J, Vuillemin T, Lädrach K, Sutter F. Ther Umsch; 1987 Feb; 44(2):137-50. PubMed ID: 3576504 [No Abstract] [Full Text] [Related]
15. [Stress tests of reconstruction plates for bridging mandibular angle defects]. Knoll WD, Gaida A, Maurer P. Mund Kiefer Gesichtschir; 2004 Jul; 8(4):237-43. PubMed ID: 15293119 [Abstract] [Full Text] [Related]
16. "A" shape plate for open rigid internal fixation of mandible condyle neck fracture. Kozakiewicz M, Swiniarski J. J Craniomaxillofac Surg; 2014 Sep; 42(6):730-7. PubMed ID: 24359864 [Abstract] [Full Text] [Related]
17. The fitting accuracy of pre-bend reconstruction plates and their impact on the temporomandibular joint. Wurm MC, Hagen J, Nkenke E, Neukam FW, Schlittenbauer T. J Craniomaxillofac Surg; 2019 Jan; 47(1):53-59. PubMed ID: 30470467 [Abstract] [Full Text] [Related]
18. New concepts in the reconstruction of mandibular defects following tumor resection. Raveh Y, Stich H, Sutter F, Greiner R. J Oral Maxillofac Surg; 1983 Jan; 41(1):3-16. PubMed ID: 6571737 [Abstract] [Full Text] [Related]
19. Assessment of plate use for mandibular reconstruction: has changing technology made a difference? Klotch DW, Gal TJ, Gal RL. Otolaryngol Head Neck Surg; 1999 Oct; 121(4):388-92. PubMed ID: 10504593 [Abstract] [Full Text] [Related]
20. The biomechanical aspects of reconstruction for segmental defects of the mandible: a finite element study to assess the optimisation of plate and screw factors. Bujtár P, Simonovics J, Váradi K, Sándor GK, Avery CM. J Craniomaxillofac Surg; 2014 Sep; 42(6):855-62. PubMed ID: 24467871 [Abstract] [Full Text] [Related] Page: [Next] [New Search]