These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


PUBMED FOR HANDHELDS

Journal Abstract Search


189 related items for PubMed ID: 31659082

  • 21. The impact of pneumatic tube system on routine laboratory parameters: a systematic review and meta-analysis.
    Kapoula GV, Kontou PI, Bagos PG.
    Clin Chem Lab Med; 2017 Oct 26; 55(12):1834-1844. PubMed ID: 28593926
    [Abstract] [Full Text] [Related]

  • 22. Air bubbles and hemolysis of blood samples during transport by pneumatic tube systems.
    Mullins GR, Bruns DE.
    Clin Chim Acta; 2017 Oct 26; 473():9-13. PubMed ID: 28803746
    [Abstract] [Full Text] [Related]

  • 23. Smartphone monitoring of pneumatic tube system-induced sample hemolysis.
    Mullins GR, Harrison JH, Bruns DE.
    Clin Chim Acta; 2016 Nov 01; 462():1-5. PubMed ID: 27553857
    [Abstract] [Full Text] [Related]

  • 24. A new assay falsely increases lactate dehydrogenase in plasma but not in serum.
    Rasmussen MS, Pedersen L.
    Clin Biochem; 2024 Oct 01; 131-132():110804. PubMed ID: 39079578
    [Abstract] [Full Text] [Related]

  • 25. Validation of a single specimen pneumatic tube system in the clinical laboratory.
    Dong XC, Li B, Hao XK, Li CF, Zeng XF.
    Ann Biol Clin (Paris); 2024 Sep 19; 82(4):439-445. PubMed ID: 39245903
    [Abstract] [Full Text] [Related]

  • 26. Effects of one directional pneumatic tube system on routine hematology and chemistry parameters; A validation study at a tertiary care hospital.
    Lee AJ, Suk Suh H, Jeon CH, Kim SG.
    Pract Lab Med; 2017 Dec 19; 9():12-17. PubMed ID: 29034301
    [Abstract] [Full Text] [Related]

  • 27. Analytical imprecision of lactate dehydrogenase in primary serum tubes.
    Buonocore R, Avanzini P, Aloe R, Lippi G.
    Ann Clin Biochem; 2016 May 19; 53(Pt 3):405-8. PubMed ID: 26113736
    [Abstract] [Full Text] [Related]

  • 28. Residual Negative Pressure in Vacuum Blood-Collection Tube and Hemolysis in Pediatric Blood Specimens.
    Hu J, Zhang QX, Xiao TT, Pan MC, Cai YM.
    Lab Med; 2020 Jan 02; 51(1):41-46. PubMed ID: 31185079
    [Abstract] [Full Text] [Related]

  • 29. Investigation of the effects of pneumatic tube transport system on routine biochemistry, hematology, and coagulation tests in Ankara City Hospital.
    Yurt EF, Akbiyik F, Bicer C.
    Clin Chem Lab Med; 2022 Apr 26; 60(5):707-713. PubMed ID: 35167733
    [Abstract] [Full Text] [Related]

  • 30. Parameters for Validating a Hospital Pneumatic Tube System.
    Farnsworth CW, Webber DM, Krekeler JA, Budelier MM, Bartlett NL, Gronowski AM.
    Clin Chem; 2019 May 26; 65(5):694-702. PubMed ID: 30808643
    [Abstract] [Full Text] [Related]

  • 31. Evaluation of the pneumatic tube system for transportation of packed red cell units.
    Dhar S, Basu S, Chakraborty S, Sinha S.
    Asian J Transfus Sci; 2015 May 26; 9(2):195-8. PubMed ID: 26420944
    [Abstract] [Full Text] [Related]

  • 32. Check-in and sorting of centrifuged serum and lithium-heparin tubes may be unsuitable using a bulk input module.
    Da Rin G, Lippi G.
    J Lab Autom; 2014 Oct 26; 19(5):474-7. PubMed ID: 24865175
    [Abstract] [Full Text] [Related]

  • 33. Pneumatic tube system induced haemolysis: assessing sample type susceptibility to haemolysis.
    Sodi R, Darn SM, Stott A.
    Ann Clin Biochem; 2004 May 26; 41(Pt 3):237-40. PubMed ID: 15117440
    [Abstract] [Full Text] [Related]

  • 34. Interindividual variability of hemolysis in plasma samples during pneumatic tube system transport.
    Gomez-Rioja R, Fernandez-Calle P, Alcaide MJ, Madero R, Oliver P, Iturzaeta JM, Buno A.
    Clin Chem Lab Med; 2013 Oct 26; 51(10):e231-3. PubMed ID: 23633466
    [No Abstract] [Full Text] [Related]

  • 35. Impact of Pneumatic Transport System on Preanalytical Phase Affecting Clinical Biochemistry Results.
    Kumari S, Kumar S, Bharti N, Shekhar R.
    J Lab Physicians; 2023 Mar 26; 15(1):48-55. PubMed ID: 37064988
    [Abstract] [Full Text] [Related]

  • 36. What is the acceptable hemolysis index for the measurements of plasma potassium, LDH and AST?
    Rousseau N, Pige R, Cohen R, Pecquet M.
    Ann Biol Clin (Paris); 2016 Jun 01; 74(3):323-8. PubMed ID: 27159801
    [Abstract] [Full Text] [Related]

  • 37. [Lactate Dehydrogenase - Old Tumour Marker in the Light of Current Knowledge and Preanalytic Conditions].
    Greplová K, Selingerová I, Valík D, Pilatova K, Češková M, Zdražilová Dubská L.
    Klin Onkol; 2017 Jun 01; 30(Supplementum1):156-158. PubMed ID: 28471194
    [Abstract] [Full Text] [Related]

  • 38. Assessment of a serum separator device for obtaining serum specimens suitable for clinical analyses.
    Laessig RH, Westgard JO, Carey RN, Hassemer DJ, Schwartz TH, Feldbruegge DH.
    Clin Chem; 1976 Feb 01; 22(2):235-9. PubMed ID: 1248126
    [Abstract] [Full Text] [Related]

  • 39. Lactic Dehydrogenase in the In Vitro Evaluation of Hemolytic Properties of Ventricular Assist Device.
    Li D, Wu Q, Liu S, Chen Y, Chen H, Ruan Y, Zhang Y.
    Artif Organs; 2017 Nov 01; 41(11):E274-E284. PubMed ID: 28722142
    [Abstract] [Full Text] [Related]

  • 40. Prevention of hemolysis in blood samples collected from intravenous catheters.
    Lippi G, Avanzini P, Cervellin G.
    Clin Biochem; 2013 May 01; 46(7-8):561-4. PubMed ID: 23391635
    [Abstract] [Full Text] [Related]


    Page: [Previous] [Next] [New Search]
    of 10.